ABB

ABB Inora 1 Gang RJ45 Cat 5e Data Outlet Classic Grey BL331-G

In Stock
47.41
EXCL.VAT
Incl. 5% VAT AED 49.78

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • RJ45 Cat 5E supports structured network links.
    • One-gang layout suits organized cabling.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • The clean faceplate suits modern interiors.
    • Classic Grey finish supports coordinated wall fittings.

Features & Benefits

Product Type

1 Gang RJ45 Cat 5E Data Outlet from the ABB Inora wiring-accessory range.

Model

BL331-G identifies the classic grey finish variant.

Configuration

1 Gang configuration is designed for ethernet network connections.

Connector Type

RJ45 Cat 5E provides the stated communication or signal interface.

Installation

Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 5733 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in Classic Grey suit ethernet network connections in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

Classic Grey

Quantity Unit

PCS

Model No

BL331-G

Brands

ABB

Item Type

Data Socket

Number of Gang

1 Gang

Connector Type

RJ45 Cat 5E

Dimension

86 x 38.8 x 86 mm

Height

86 mm

Width

38.8 mm

Depth

86 mm

Usage

Ethernet Network Connections

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL331-G is a single-gang CAT.5e data socket designed to provide a fixed network connection point in residential, commercial and light-industrial buildings. Its classic grey finish suits contemporary interiors, while the 1-gang configuration is suitable for locations requiring one wired Ethernet outlet.

When installed as part of a complete standards-compliant Category 5e channel, the socket can support Ethernet speeds of up to 1 Gbps over a maximum channel length of 100 metres. Actual performance depends on the cable category, patch cords, termination quality, network equipment, route length and surrounding electrical interference.

It is suitable for structured cabling outlets in UAE villas, apartments, offices, retail units, schools, hotels and other buildings. Typical connection points include workstations, smart televisions, IP phones, wireless access points, printers, network switches and other Ethernet-enabled equipment.

Yes, it is relevant to UAE residential and commercial projects requiring dependable wired data points. The installation should follow the approved project specification, local authority requirements and the applicable structured-cabling standards. Consultants and contractors should also confirm compatibility with the selected faceplate system, back box, cable and termination scheme before procurement.

Install the socket in a compatible wall box or mounting arrangement, route the Category 5e cable without crushing or excessive bending, and terminate each conductor according to one consistent T568A or T568B wiring scheme. Maintain the pair twists as close as possible to the termination point, secure the mechanism and faceplate, fit the identification label where required, and test the completed link with a calibrated cable tester. Installation should be carried out by a qualified ELV or structured-cabling technician.

Either T568A or T568B may be used if supported by the socket termination markings and project specification. The same scheme must be applied at both ends of the cable link. T568B is commonly encountered in many commercial installations, but contractors should always follow the consultant-approved cabling schedule and the convention already used on the site.

Use a genuine Category 5e, four-pair solid-conductor horizontal cable with the appropriate fire-performance and installation rating for the project. Select UTP or screened cable according to the design and electromagnetic environment. For concealed UAE building installations, the cable specification should comply with the approved drawings, fire and life-safety requirements, and relevant authority or consultant requirements.

Physical compatibility depends on the socket terminals and the conductor size specified by the manufacturer. Even where CAT.6 cable can be terminated, the complete link will generally be limited to the performance category of its lowest-rated component, which in this case is CAT.5e. Use a CAT.6-rated outlet when the project requires certified Category 6 channel performance.

Route data cables separately from mains power cables and high-interference equipment, following the separation distances and containment requirements in the approved design. Avoid sharp bends, excessive pulling force, tight cable ties and long sections of untwisted conductors at the socket. Cross power cables at approximately 90 degrees where unavoidable, and use properly earthed screened components if the specified cabling system requires shielding.

The required back-box depth depends on the ABB Inora mounting system, cable entry direction and available bend radius. Use a compatible 1-gang box and matching ABB Inora accessories, allowing enough internal space to terminate and coil the cable without kinking or compressing it. Check the product dimensions and approved shop drawings before preparing wall openings or ordering back boxes.

At minimum, test wire map, continuity, opens, shorts, crossed pairs, split pairs and cable length. For projects requiring performance certification, use a calibrated field tester to verify the permanent link or channel against the specified Category 5e limits. Label both ends clearly and retain test reports for inspection, handover and future maintenance.

Common references include ISO/IEC 11801 and the ANSI/TIA-568 series for generic and commercial structured cabling. Installation, fire rating, containment, labelling and testing must also follow the UAE project's approved specifications and the requirements of the relevant local authority, telecom provider and civil defence authority where applicable.

This type of decorative data socket is generally intended for protected indoor locations unless ABB documentation specifically states an outdoor or ingress-protection rating. For balconies, gardens, construction cabins or exposed areas, install it inside a suitable weatherproof enclosure with the required IP rating and use outdoor-rated or UV-resistant cabling where applicable.

A correctly installed Category 5e link can carry compatible Power over Ethernet services, but suitability depends on the PoE standard, cable construction, bundle size, ambient temperature, connectors and network equipment. For higher-power PoE applications, the designer should verify current and thermal requirements across the complete cabling channel rather than relying on the outlet category alone.

Keep the front surface and port free from dust, paint and construction debris. Clean the faceplate with a soft, dry or lightly damp cloth and avoid solvents or abrasive cleaners. Do not insert damaged plugs, and arrange inspection and retesting if the connection becomes intermittent or if the outlet has been exposed to moisture, impact or renovation work.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy