ABB

ABB Inora 1 Gang RJ45 Cat 6 Data Outlet Starry Black BL333-885

In Stock
42.97
EXCL.VAT
Incl. 5% VAT AED 45.12

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • RJ45 Cat 6 supports structured network links.
    • One-gang layout suits organized cabling.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • The clean faceplate suits modern interiors.
    • Starry Black finish supports coordinated wall fittings.

Features & Benefits

Product Type

1 Gang RJ45 Cat 6 Data Outlet from the ABB Inora wiring-accessory range.

Model

BL333-885 identifies the starry black finish variant.

Configuration

1 Gang configuration is designed for ethernet network connections.

Connector Type

RJ45 Cat 6 provides the stated communication or signal interface.

Installation

Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 5733 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in Starry Black suit ethernet network connections in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

Starry Black

Quantity Unit

PCS

Model No

BL333-885

Brands

ABB

Item Type

Data Socket

Number of Gang

1 Gang

Connector Type

RJ45 Cat 6

Dimension

86 x 38.8 x 86 mm

Height

86 mm

Width

38.8 mm

Depth

86 mm

Usage

Ethernet Network Connections

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL333-885 is a single-gang CAT.6 data socket from the Inora wiring-accessories range, finished in Starry Black. It provides a dedicated network outlet for structured Ethernet cabling in homes, offices, hotels, shops and other UAE construction projects. Its one-gang format is suitable where a single fixed data connection is required.

This socket can be used to connect computers, smart televisions, IP phones, wireless access points, network printers, CCTV equipment and other Ethernet-enabled devices. It is suitable for residential villas, apartments, offices, meeting rooms, hospitality developments and commercial fit-outs when installed as part of a correctly designed CAT.6 structured cabling system.

A properly installed CAT.6 permanent link is commonly used for Gigabit Ethernet and can support higher data rates over distances permitted by the applicable Ethernet and structured-cabling standards. Actual performance depends on the complete channel, including the cable category, patch panels, patch cords, connector termination, route length and installation quality. The outlet alone does not determine the final network speed.

Route the specified CAT.6 cable to a compatible flush or surface mounting box, maintain the cable's twist as close as possible to the termination point, and terminate all conductors using the wiring sequence marked on the data module. Use either T568A or T568B consistently throughout the installation, secure the cable without crushing it, fit the socket into the mounting box and install the Starry Black faceplate. A qualified ELV or structured-cabling technician should complete and test the installation.

Either T568A or T568B may be used if it is supported by the module's termination markings and applied consistently at both ends of the cable. T568B is frequently encountered in commercial network installations, but the project consultant's specification should always take priority. Mixing the two schemes on the same permanent link can create an unintended crossover connection and lead to commissioning problems.

Use genuine CAT.6 four-pair cable that matches the project's structured-cabling design, fire-performance requirements and environmental conditions. Confirm whether the outlet module is intended for unshielded or shielded cabling before installation, as this is not established by the supplied product data. Avoid mixing components of incompatible shielding types, conductor sizes or lower performance categories if verified CAT.6 channel performance is required.

Data cabling should be separated from power cables in accordance with the UAE project's electrical, ELV and structured-cabling requirements. Where routes must cross, a near-right-angle crossing is generally preferred, and suitable segregation or partitioned containment should be used. Proper separation reduces electromagnetic interference and helps maintain network performance. Always follow approved drawings, local authority requirements and the consultant's specifications.

Yes, it is suited to contemporary UAE residential and commercial interiors where a dark-finish network outlet is required. It can be specified for villas, apartments, offices, retail units and hospitality projects, subject to compatibility with the selected mounting box and cabling system. For regulated or consultant-led projects, verify the approved material submittal, project specifications and relevant UAE authority requirements before procurement.

It may form part of a Power over Ethernet link for devices such as IP cameras, access points and VoIP phones when every component in the channel is appropriately rated and correctly terminated. PoE capability depends on the network switch or injector, cable construction, connector compatibility, bundle size, cable length and thermal conditions. The required IEEE PoE standard and project load calculations should be confirmed by the network designer.

At minimum, test the link for wire map, continuity, opens, shorts, reversals and split pairs. For construction handover or certified CAT.6 performance, use a calibrated cable certification tester to check parameters such as insertion loss, return loss and near-end crosstalk against the specified cabling standard. Label the outlet and retain test reports as part of the ELV commissioning documentation.

Do not untwist conductor pairs more than necessary at the termination, exceed the cable manufacturer's bend radius, crush the cable with tight ties or pull it beyond its permitted tension. Keep the cable away from heat sources, moisture and electrical interference, and avoid sharp bends inside the back box. Correct termination, suitable containment and adequate box depth are essential for reliable network performance.

The supplied product information does not state an outdoor weatherproof or IP rating, so it should be treated as an indoor data outlet unless ABB documentation confirms otherwise. For outdoor areas, balconies, plant rooms or dusty and humid locations in the UAE, install it only within a suitably rated weatherproof enclosure or select a purpose-built outdoor data socket that meets the project's ingress-protection requirements.

Confirm the mounting-box dimensions, screw spacing, available depth and compatibility with the ABB Inora range before ordering. Sufficient back-box depth is important because CAT.6 cable must enter without tight bending or pressure on the termination. In renovation projects, inspect the existing box and conduit route, as older accessories may use different mounting arrangements.

Disconnect connected equipment where practical and wipe the surface with a soft, dry or slightly damp cloth. Do not use abrasive pads, solvents, strong chemicals or excessive water, as these may damage the finish or enter the data module. If network performance becomes intermittent, have the patch lead, socket termination and permanent cable link inspected and tested by a qualified technician.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy