FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- RJ45 Cat 6 supports structured network links.
- One-gang layout suits organized cabling.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- The clean faceplate suits modern interiors.
- White finish supports coordinated wall fittings.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
1 Gang RJ45 Cat 6 Data Outlet from the ABB Inora wiring-accessory range.
Model
BL333 identifies the white finish variant.
Configuration
1 Gang configuration is designed for ethernet network connections.
Connector Type
RJ45 Cat 6 provides the stated communication or signal interface.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 5733 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit ethernet network connections in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL333
Brands
ABB
Item Type
Data Socket
Number of Gang
1 Gang
Connector Type
RJ45 Cat 6
Dimension
86 x 38.8 x 86 mm
Height
86 mm
Width
38.8 mm
Depth
86 mm
Usage
Ethernet Network Connections
Installation Type
Flush Mounted
Frequently Asked Questions
Is this CAT6 data socket suitable for UAE villas, apartments and offices?
Yes, it is suitable for structured cabling points in UAE residential and commercial interiors when installed as part of a compatible CAT6 system. Common uses include home networks, workstations, meeting rooms, smart-home hubs, Wi-Fi access points, IP phones and IP surveillance equipment. For major projects, confirm the approved brand, cabling category and submittal requirements with the consultant.
How should the ABB Inora white CAT6 data socket be maintained?
Keep the outlet dry and free from construction dust, paint and plaster. Clean the faceplate with a soft, lightly damp cloth after isolating connected equipment, and avoid solvents or abrasive cleaners. Inspect loose fittings or damaged ports during maintenance and retest the data link if connectivity becomes intermittent.
What can cause slow or unstable network performance after installation?
Common causes include incorrect T568A or T568B termination, excessive untwisting of conductor pairs, damaged cable, tight bends, poor-quality patch leads, excessive cable length, electrical interference, incompatible components or a fault in the router or switch. Recheck the wire map and certify the permanent link before replacing the socket.
How should the completed CAT6 outlet be tested?
At minimum, use a cable tester to check continuity, wire map, opens, shorts, reversals and split pairs. For commercial projects requiring CAT6 certification, use a calibrated field certification tester to measure parameters such as insertion loss, return loss, propagation delay and crosstalk. Retain test reports and outlet labels for handover documentation.
Is the ABB BL333 data socket intended for indoor or outdoor use?
This type of white decorative data socket is generally intended for dry indoor locations. For balconies, gardens, construction-site cabins, plant areas or other locations exposed to dust, moisture, heat or sunlight, use an appropriately rated weatherproof enclosure and confirm the required IP rating and environmental suitability.
Can the ABB Inora CAT6 socket be used for PoE devices?
It can form part of a Power over Ethernet link for compatible equipment such as IP cameras, VoIP phones and wireless access points, provided the complete channel uses compliant CAT6 components and the cable, connectors, patch panel, patch leads and network switch support the required PoE standard and power level. Cable bundling, heat rise and installation conditions must also be considered.
Which standards should be considered when installing this CAT6 data socket in the UAE?
The complete structured cabling installation should follow the consultant's specification and relevant standards such as ISO/IEC 11801 and ANSI/TIA-568.2-D, together with applicable UAE electrical, fire-safety, telecom and local authority requirements. Project-specific requirements from the relevant emirate, developer or service provider should also be checked before installation.
Can this ABB CAT6 outlet be installed near an electrical socket?
A data outlet may be positioned near a power outlet for user convenience, but the data and power cabling must be routed and segregated according to applicable electrical, structured cabling and project requirements. Separate containment or approved partitions may be required. Avoid parallel runs close to mains cables where electromagnetic interference could affect network performance.
Is the ABB Inora BL333 suitable for construction and fit-out projects?
Yes. The single-gang format is practical for new construction, renovation and fit-out works that require one dedicated network outlet. Contractors should coordinate outlet locations with architectural drawings, furniture layouts, IT requirements and MEP services before closing walls or ceilings.
What is the ABB Inora 1 Gang CAT.6 Data Socket White BL333?
The ABB Inora BL333 is a single-gang Category 6 data outlet designed to provide a dedicated wired network connection in residential, commercial and construction projects. Its white finish suits modern interiors, while the 1-gang configuration makes it suitable for individual data points in offices, villas, apartments, shops, hotels and other UAE properties.
Can the ABB Inora BL333 be installed in a standard UAE wall box?
The product is intended for a 1-gang installation, but back-box dimensions, mounting centres, depth and compatibility should be checked against the ABB Inora accessory system and the box used on the project. Adequate depth is important because CAT6 cable must not be sharply bent or compressed behind the outlet.
What installation practices help maintain CAT6 performance?
Maintain the cable manufacturer's minimum bend radius, do not over-tighten cable ties, avoid kinks and compression, and keep conductor pairs twisted up to the termination. Keep data cables separated from power circuits and sources of electromagnetic interference, use suitable containment, avoid exceeding pulling-tension limits, and do not create unnecessary joints. Each completed data point should be identified and tested.
Should the ABB CAT6 socket be wired to T568A or T568B?
Either T568A or T568B may be used if permitted by the project specification, but the same wiring scheme must be applied at both ends of the cable. T568B is widely encountered in commercial installations, while some projects specify T568A. Contractors should follow the consultant-approved structured cabling schedule and label every outlet consistently.
How is the ABB Inora 1 Gang CAT6 data socket installed?
Route the CAT6 cable to a compatible concealed or surface-mounted back box, leaving enough cable for termination without excessive slack. Remove only the necessary outer sheath, preserve the pair twists as close as possible to the termination point, arrange conductors according to the selected T568A or T568B scheme, terminate them with the appropriate tool, secure the cable without crushing it, fit the socket and faceplate, and test the completed link with a suitable network cable tester.
Which network cable should be used with the ABB BL333 data socket?
Use genuine solid-conductor CAT6 installation cable of the appropriate type for the project, such as U/UTP or a screened construction where required by the design. Cable conductor size, screening arrangement and termination compatibility should be confirmed before installation. Avoid mixing lower-category cable or accessories because the link is only rated according to its lowest-performing component.
Frequently Asked Questions
Yes, it is suitable for structured cabling points in UAE residential and commercial interiors when installed as part of a compatible CAT6 system. Common uses include home networks, workstations, meeting rooms, smart-home hubs, Wi-Fi access points, IP phones and IP surveillance equipment. For major projects, confirm the approved brand, cabling category and submittal requirements with the consultant.
Keep the outlet dry and free from construction dust, paint and plaster. Clean the faceplate with a soft, lightly damp cloth after isolating connected equipment, and avoid solvents or abrasive cleaners. Inspect loose fittings or damaged ports during maintenance and retest the data link if connectivity becomes intermittent.
Common causes include incorrect T568A or T568B termination, excessive untwisting of conductor pairs, damaged cable, tight bends, poor-quality patch leads, excessive cable length, electrical interference, incompatible components or a fault in the router or switch. Recheck the wire map and certify the permanent link before replacing the socket.
At minimum, use a cable tester to check continuity, wire map, opens, shorts, reversals and split pairs. For commercial projects requiring CAT6 certification, use a calibrated field certification tester to measure parameters such as insertion loss, return loss, propagation delay and crosstalk. Retain test reports and outlet labels for handover documentation.
This type of white decorative data socket is generally intended for dry indoor locations. For balconies, gardens, construction-site cabins, plant areas or other locations exposed to dust, moisture, heat or sunlight, use an appropriately rated weatherproof enclosure and confirm the required IP rating and environmental suitability.
It can form part of a Power over Ethernet link for compatible equipment such as IP cameras, VoIP phones and wireless access points, provided the complete channel uses compliant CAT6 components and the cable, connectors, patch panel, patch leads and network switch support the required PoE standard and power level. Cable bundling, heat rise and installation conditions must also be considered.
The complete structured cabling installation should follow the consultant's specification and relevant standards such as ISO/IEC 11801 and ANSI/TIA-568.2-D, together with applicable UAE electrical, fire-safety, telecom and local authority requirements. Project-specific requirements from the relevant emirate, developer or service provider should also be checked before installation.
A data outlet may be positioned near a power outlet for user convenience, but the data and power cabling must be routed and segregated according to applicable electrical, structured cabling and project requirements. Separate containment or approved partitions may be required. Avoid parallel runs close to mains cables where electromagnetic interference could affect network performance.
Yes. The single-gang format is practical for new construction, renovation and fit-out works that require one dedicated network outlet. Contractors should coordinate outlet locations with architectural drawings, furniture layouts, IT requirements and MEP services before closing walls or ceilings.
The ABB Inora BL333 is a single-gang Category 6 data outlet designed to provide a dedicated wired network connection in residential, commercial and construction projects. Its white finish suits modern interiors, while the 1-gang configuration makes it suitable for individual data points in offices, villas, apartments, shops, hotels and other UAE properties.
The product is intended for a 1-gang installation, but back-box dimensions, mounting centres, depth and compatibility should be checked against the ABB Inora accessory system and the box used on the project. Adequate depth is important because CAT6 cable must not be sharply bent or compressed behind the outlet.
Maintain the cable manufacturer's minimum bend radius, do not over-tighten cable ties, avoid kinks and compression, and keep conductor pairs twisted up to the termination. Keep data cables separated from power circuits and sources of electromagnetic interference, use suitable containment, avoid exceeding pulling-tension limits, and do not create unnecessary joints. Each completed data point should be identified and tested.
Either T568A or T568B may be used if permitted by the project specification, but the same wiring scheme must be applied at both ends of the cable. T568B is widely encountered in commercial installations, while some projects specify T568A. Contractors should follow the consultant-approved structured cabling schedule and label every outlet consistently.
Route the CAT6 cable to a compatible concealed or surface-mounted back box, leaving enough cable for termination without excessive slack. Remove only the necessary outer sheath, preserve the pair twists as close as possible to the termination point, arrange conductors according to the selected T568A or T568B scheme, terminate them with the appropriate tool, secure the cable without crushing it, fit the socket and faceplate, and test the completed link with a suitable network cable tester.
Use genuine solid-conductor CAT6 installation cable of the appropriate type for the project, such as U/UTP or a screened construction where required by the design. Cable conductor size, screening arrangement and termination compatibility should be confirmed before installation. Avoid mixing lower-category cable or accessories because the link is only rated according to its lowest-performing component.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
