- The 13A rating suits appliance power loads.
- Two-gang double pole switching controls supply.
- Safety shutters help guard live socket contacts.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- White finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
2 Gang Switched Socket Double Pole from the ABB Inora wiring-accessory range.
Model
BL239 identifies the white finish variant.
Configuration
2 Gang Double Pole configuration is designed for switched appliance power connection.
Electrical Rating
13A at 250V AC supports the stated fixed-wiring application.
Installation
Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Socket Safety
The Inora socket design uses safety shutters to help protect users from accidental access to live contacts.
Standard Compliance
BS 1363-2; SS 145-2; SASO 2203; MS 589-2 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit switched appliance power connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL239
Brands
ABB
Item Type
Double Socket
Number of Gang
2 Gang
Pole
2 Pole
Rated Current
13A
Rated Voltage
250V AC
Dimension
86 x 30.8 x 146 mm
Switch Type
Switched Socket
Height
146 mm
Width
30.8 mm
Depth
86 mm
Usage
Switched appliance power connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 13A DP Double Switched Socket White BL239?
The ABB Inora BL239 is a white double switched wall socket designed to provide two 13A outlets from one accessory position. Each outlet has an individual double-pole switch, allowing the connected appliance to be isolated without removing its plug. It is suitable for residential, commercial and light-duty construction projects requiring a practical British-style socket solution.
What does DP mean on the ABB Inora BL239 socket?
DP stands for double pole. When an outlet is switched off, its double-pole mechanism disconnects both the live and neutral conductors. This provides more complete local isolation than a single-pole switch and is particularly relevant for electrical installations in which neutral isolation is required by the project design or applicable wiring regulations.
What type of plugs can be used with this 13A double switched socket?
The BL239 is intended for compatible 13A British-style fused plugs commonly used in the UAE. Before connection, confirm that the plug format, appliance voltage, frequency and current demand match the electrical installation. Plug adaptors should not be used as a permanent substitute for the correct plug and socket arrangement.
Is the ABB Inora BL239 suitable for UAE electrical installations?
It is suitable for many UAE residential and commercial projects that specify 13A British-style switched sockets. Installation must follow the approved project drawings, local authority requirements and the relevant UAE electricity distributor's regulations, such as those applicable in Dubai, Abu Dhabi or the respective emirate. A licensed electrician should verify final compliance before installation.
Can both outlets on the ABB BL239 be used at the same time?
Yes, both outlets can be used simultaneously, provided the connected load remains within the rating of the socket, circuit, protective device and wiring. The 13A marking should not be interpreted as permission to exceed the circuit's designed capacity. High-load appliances should be checked carefully, and fixed heavy equipment may require a dedicated circuit or connection unit.
Where can the ABB Inora double switched socket be installed?
This socket is suitable for dry indoor locations such as villas, apartments, offices, shops, workshops, staff accommodation and other commercial interiors. Typical applications include general-purpose outlets for computers, televisions, chargers and suitable household appliances. The selected position should remain accessible and comply with project requirements for mounting height, clearances and electrical zoning.
Can the ABB Inora BL239 be installed in kitchens, bathrooms or outdoor areas?
In kitchens, it should be positioned away from sinks, water sources, heat and cooking equipment in accordance with the approved electrical layout. Bathrooms and wet areas have stricter electrical zones and protection requirements, so this socket should only be used where specifically permitted. For outdoor, washdown or exposed locations, use a suitably IP-rated weatherproof socket instead.
How is the ABB Inora BL239 double socket installed?
Installation should be completed with the circuit isolated, locked out where required and proven dead using suitable test equipment. A qualified electrician should mount the socket on a compatible wall box, identify the live, neutral and earth conductors, terminate them at the correctly marked terminals and tighten connections to the manufacturer's requirements. After fitting the faceplate, the circuit should be inspected and electrically tested before energisation.
What wall box and wiring are required for the ABB BL239 socket?
Use a compatible double-gang flush or surface mounting box with adequate depth for the terminals and conductor bend radius. Cable size and circuit arrangement must be selected by the electrical designer or licensed electrician according to the connected load, installation method, ambient temperature, voltage drop and protective device. The protective earth conductor must be connected correctly, including bonding a metal back box where required.
What protection should be provided for a 13A switched socket circuit in the UAE?
The circuit should have an appropriately rated overcurrent protective device and any required residual-current protection. The exact MCB or RCBO rating, cable size and circuit configuration depend on the approved design and local authority rules. UAE conditions such as high ambient temperatures and grouped cables can affect conductor capacity, so appropriate derating must be considered.
Is the ABB Inora BL239 suitable for construction and fit-out projects?
Yes, the BL239 is relevant to villa construction, apartment developments, office fit-outs, retail spaces and maintenance work where double 13A switched outlets are specified. Its two independently controlled outlets can reduce the number of accessory positions required. Contractors should verify the model, finish, mounting-box compatibility and consultant-approved material schedule before bulk installation.
Why is double-pole switching useful for appliances?
Double-pole switching isolates both live and neutral conductors when the socket is turned off, offering a clear local control point for connected equipment. This is useful for routine shutdown and appliance servicing procedures. However, the switch is not a substitute for locking out and proving a circuit dead before electrical work.
How should the ABB Inora white switched socket be maintained?
Keep the faceplate clean and dry, using a soft cloth without abrasive cleaners or excessive moisture. Periodically check for loose mounting, discoloration, unusual heat, buzzing, cracking or a weak switch action. Stop using the outlet if damage or overheating is observed and arrange inspection by a qualified electrician; internal parts should not be repaired by untrained users.
What should buyers check before ordering the ABB Inora 13A DP Double Switched Socket BL239?
Confirm that the project requires model BL239, a white finish, two switched 13A outlets and double-pole operation. Also check the plug standard, system voltage, mounting-box dimensions, indoor-use conditions and quantity shown on the electrical schedule. For consultant-controlled UAE projects, obtain material approval and verify compliance documentation against the latest project and authority requirements.
Frequently Asked Questions
The ABB Inora BL239 is a white double switched wall socket designed to provide two 13A outlets from one accessory position. Each outlet has an individual double-pole switch, allowing the connected appliance to be isolated without removing its plug. It is suitable for residential, commercial and light-duty construction projects requiring a practical British-style socket solution.
DP stands for double pole. When an outlet is switched off, its double-pole mechanism disconnects both the live and neutral conductors. This provides more complete local isolation than a single-pole switch and is particularly relevant for electrical installations in which neutral isolation is required by the project design or applicable wiring regulations.
The BL239 is intended for compatible 13A British-style fused plugs commonly used in the UAE. Before connection, confirm that the plug format, appliance voltage, frequency and current demand match the electrical installation. Plug adaptors should not be used as a permanent substitute for the correct plug and socket arrangement.
It is suitable for many UAE residential and commercial projects that specify 13A British-style switched sockets. Installation must follow the approved project drawings, local authority requirements and the relevant UAE electricity distributor's regulations, such as those applicable in Dubai, Abu Dhabi or the respective emirate. A licensed electrician should verify final compliance before installation.
Yes, both outlets can be used simultaneously, provided the connected load remains within the rating of the socket, circuit, protective device and wiring. The 13A marking should not be interpreted as permission to exceed the circuit's designed capacity. High-load appliances should be checked carefully, and fixed heavy equipment may require a dedicated circuit or connection unit.
This socket is suitable for dry indoor locations such as villas, apartments, offices, shops, workshops, staff accommodation and other commercial interiors. Typical applications include general-purpose outlets for computers, televisions, chargers and suitable household appliances. The selected position should remain accessible and comply with project requirements for mounting height, clearances and electrical zoning.
In kitchens, it should be positioned away from sinks, water sources, heat and cooking equipment in accordance with the approved electrical layout. Bathrooms and wet areas have stricter electrical zones and protection requirements, so this socket should only be used where specifically permitted. For outdoor, washdown or exposed locations, use a suitably IP-rated weatherproof socket instead.
Installation should be completed with the circuit isolated, locked out where required and proven dead using suitable test equipment. A qualified electrician should mount the socket on a compatible wall box, identify the live, neutral and earth conductors, terminate them at the correctly marked terminals and tighten connections to the manufacturer's requirements. After fitting the faceplate, the circuit should be inspected and electrically tested before energisation.
Use a compatible double-gang flush or surface mounting box with adequate depth for the terminals and conductor bend radius. Cable size and circuit arrangement must be selected by the electrical designer or licensed electrician according to the connected load, installation method, ambient temperature, voltage drop and protective device. The protective earth conductor must be connected correctly, including bonding a metal back box where required.
The circuit should have an appropriately rated overcurrent protective device and any required residual-current protection. The exact MCB or RCBO rating, cable size and circuit configuration depend on the approved design and local authority rules. UAE conditions such as high ambient temperatures and grouped cables can affect conductor capacity, so appropriate derating must be considered.
Yes, the BL239 is relevant to villa construction, apartment developments, office fit-outs, retail spaces and maintenance work where double 13A switched outlets are specified. Its two independently controlled outlets can reduce the number of accessory positions required. Contractors should verify the model, finish, mounting-box compatibility and consultant-approved material schedule before bulk installation.
Double-pole switching isolates both live and neutral conductors when the socket is turned off, offering a clear local control point for connected equipment. This is useful for routine shutdown and appliance servicing procedures. However, the switch is not a substitute for locking out and proving a circuit dead before electrical work.
Keep the faceplate clean and dry, using a soft cloth without abrasive cleaners or excessive moisture. Periodically check for loose mounting, discoloration, unusual heat, buzzing, cracking or a weak switch action. Stop using the outlet if damage or overheating is observed and arrange inspection by a qualified electrician; internal parts should not be repaired by untrained users.
Confirm that the project requires model BL239, a white finish, two switched 13A outlets and double-pole operation. Also check the plug standard, system voltage, mounting-box dimensions, indoor-use conditions and quantity shown on the electrical schedule. For consultant-controlled UAE projects, obtain material approval and verify compliance documentation against the latest project and authority requirements.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy