- The 13A fuse protects a fixed appliance feed.
- A local switch controls the fused appliance feed.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- BS fused-unit standards support safe installation.
- White finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
13A Switched Fused Connection Unit from the ABB Inora wiring-accessory range.
Model
BL508 identifies the white finish variant.
Configuration
1 Gang configuration is designed for switched fused fixed-appliance connection.
Electrical Rating
13A at 250V AC supports the stated fixed-wiring application.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 1363-4; SS 403 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit switched fused fixed-appliance connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL508
Brands
ABB
Item Type
Fused Connection Unit
Number of Gang
1 Gang
Rated Current
13A
Rated Voltage
250V AC
Switch Type
Switched
Usage
Switched fused fixed-appliance connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 13A Switched Fused Connection Unit White BL508?
The ABB Inora BL508 is a 13A switched fused connection unit, commonly called an FCU or fused spur. It provides local switching and fuse protection for a fixed electrical appliance or a spur connected to a suitable final circuit. Its white finish is suitable for residential, commercial and light construction interiors.
What is a 13A switched fused connection unit used for?
A 13A switched fused connection unit is used to supply and isolate fixed electrical equipment while protecting the outgoing cable or appliance with a replaceable fuse. Typical applications may include water heaters, extractor fans, kitchen appliances, pumps, signage and other fixed loads, subject to the equipment rating, circuit design and manufacturer instructions.
What is the technical rating of the ABB Inora BL508 fused spur?
The BL508 is identified as a 13A switched fused connection unit. The connected load, cable size, fuse rating, circuit protective device and installation method must all be coordinated by a qualified electrician. For exact voltage, terminal capacity, pole configuration, dimensions and compliance markings, check the product label and current ABB technical datasheet before specification.
Does the ABB Inora BL508 include a switch and fuse protection?
Yes. This model combines a manual switch with a fuse carrier in one connection unit. The switch provides convenient local control or isolation, while the correctly selected fuse protects the connected equipment or outgoing conductor against excessive current. It does not replace the distribution board circuit breaker or other protection required by the electrical design.
Which fuse should be used with this 13A switched fused connection unit?
Use only a compatible fuse of the type specified on the unit or in the ABB documentation, commonly a BS 1362 cartridge fuse for this class of accessory. The fuse must be selected according to the appliance load and cable capacity and must not exceed 13A. A lower-rated fuse may be required for low-power appliances, fans, controls or smaller outgoing cables.
How is the ABB Inora BL508 installed?
Installation should be completed with the circuit safely isolated and proven dead. The electrician should confirm the supply and load terminals, connect line, neutral and protective earth conductors as marked, tighten terminals to the specified torque, fit the correctly rated fuse and secure the accessory to a compatible mounting box. Polarity, earthing, continuity, insulation resistance and functional operation should be tested before energising.
Can the ABB Inora 13A fused connection unit be installed on a ring final circuit?
A fused connection unit is commonly used to create a protected spur from a correctly designed ring final circuit. However, connection location, conductor size, maximum demand, existing spurs and protective-device coordination must be checked by a competent electrician. The completed work should comply with the approved project design and applicable UAE electrical requirements.
Is the ABB Inora BL508 suitable for UAE construction projects?
The 13A fused connection unit format is widely relevant to UAE villas, apartments, offices, retail units and other projects using British-style wiring accessories. Acceptance depends on the project specification, authority requirements and product certification. Contractors should verify the current ABB compliance documentation and follow the relevant electricity authority regulations, such as DEWA or the applicable local utility, together with recognised wiring standards.
Can this white ABB fused spur be used in kitchens, bathrooms or utility rooms?
It may be used for suitable fixed appliances when installed in a permitted location. Kitchens, bathrooms and utility rooms can involve moisture, heat and restricted electrical zones, so the mounting position and enclosure protection must be assessed carefully. Do not assume the standard white unit is weatherproof or splashproof unless an appropriate IP rating is confirmed; use a suitable rated enclosure where required.
Is the ABB Inora BL508 suitable for outdoor installation?
It should not be installed directly outdoors unless ABB confirms an appropriate ingress-protection rating for the unit and the complete installation. For gardens, balconies, plant areas or exposed construction locations, mount it inside a suitable weather-resistant enclosure and provide any additional RCD protection, cable glands and environmental protection required by the electrical design.
Does this fused connection unit provide RCD or earth-leakage protection?
No RCD or earth-leakage function is indicated in the supplied product information. A switched fused connection unit provides local switching and fuse-based overcurrent protection. Where RCD protection is required, it must be provided separately through a suitable distribution-board device or another approved protective arrangement.
What should contractors check before fitting the ABB Inora BL508 to a wall box?
Before installation, verify the accessory dimensions, mounting centres, required box depth, cable entry space and compatibility with the selected flush or surface box. Also confirm conductor sizes, terminal capacity, earthing arrangements and the connected appliance load. Avoid forcing conductors behind the plate, as trapped cables or loose terminals can cause overheating and unreliable operation.
Can the ABB Inora 13A switched FCU be used for a water heater or air-conditioning equipment?
It may be suitable only when the appliance operating current does not exceed the unit rating and the appliance manufacturer permits fused-connection-unit control. Many water heaters and air-conditioning systems require higher-rated double-pole isolators, dedicated circuits or specific isolation arrangements. The equipment nameplate, installation manual and approved electrical drawings must be checked before selection.
How should the ABB Inora fused connection unit be tested after installation?
A qualified electrician should inspect conductor termination, protective-earth continuity, polarity, insulation resistance and circuit protective-device coordination. The switch and connected appliance should then be functionally tested, and terminals should show no signs of looseness or abnormal heating. Testing and documentation should follow the project specification and applicable UAE authority requirements.
What maintenance does the ABB Inora BL508 fused spur require?
Keep the faceplate clean and dry and inspect it periodically for discoloration, cracking, looseness, buzzing, burning smells or excessive heat. If the fuse operates repeatedly, do not fit a higher-rated fuse; isolate the circuit and have the appliance, cable and connections investigated by a qualified electrician. Replace damaged accessories rather than attempting temporary repairs.
Frequently Asked Questions
The ABB Inora BL508 is a 13A switched fused connection unit, commonly called an FCU or fused spur. It provides local switching and fuse protection for a fixed electrical appliance or a spur connected to a suitable final circuit. Its white finish is suitable for residential, commercial and light construction interiors.
A 13A switched fused connection unit is used to supply and isolate fixed electrical equipment while protecting the outgoing cable or appliance with a replaceable fuse. Typical applications may include water heaters, extractor fans, kitchen appliances, pumps, signage and other fixed loads, subject to the equipment rating, circuit design and manufacturer instructions.
The BL508 is identified as a 13A switched fused connection unit. The connected load, cable size, fuse rating, circuit protective device and installation method must all be coordinated by a qualified electrician. For exact voltage, terminal capacity, pole configuration, dimensions and compliance markings, check the product label and current ABB technical datasheet before specification.
Yes. This model combines a manual switch with a fuse carrier in one connection unit. The switch provides convenient local control or isolation, while the correctly selected fuse protects the connected equipment or outgoing conductor against excessive current. It does not replace the distribution board circuit breaker or other protection required by the electrical design.
Use only a compatible fuse of the type specified on the unit or in the ABB documentation, commonly a BS 1362 cartridge fuse for this class of accessory. The fuse must be selected according to the appliance load and cable capacity and must not exceed 13A. A lower-rated fuse may be required for low-power appliances, fans, controls or smaller outgoing cables.
Installation should be completed with the circuit safely isolated and proven dead. The electrician should confirm the supply and load terminals, connect line, neutral and protective earth conductors as marked, tighten terminals to the specified torque, fit the correctly rated fuse and secure the accessory to a compatible mounting box. Polarity, earthing, continuity, insulation resistance and functional operation should be tested before energising.
A fused connection unit is commonly used to create a protected spur from a correctly designed ring final circuit. However, connection location, conductor size, maximum demand, existing spurs and protective-device coordination must be checked by a competent electrician. The completed work should comply with the approved project design and applicable UAE electrical requirements.
The 13A fused connection unit format is widely relevant to UAE villas, apartments, offices, retail units and other projects using British-style wiring accessories. Acceptance depends on the project specification, authority requirements and product certification. Contractors should verify the current ABB compliance documentation and follow the relevant electricity authority regulations, such as DEWA or the applicable local utility, together with recognised wiring standards.
It may be used for suitable fixed appliances when installed in a permitted location. Kitchens, bathrooms and utility rooms can involve moisture, heat and restricted electrical zones, so the mounting position and enclosure protection must be assessed carefully. Do not assume the standard white unit is weatherproof or splashproof unless an appropriate IP rating is confirmed; use a suitable rated enclosure where required.
It should not be installed directly outdoors unless ABB confirms an appropriate ingress-protection rating for the unit and the complete installation. For gardens, balconies, plant areas or exposed construction locations, mount it inside a suitable weather-resistant enclosure and provide any additional RCD protection, cable glands and environmental protection required by the electrical design.
No RCD or earth-leakage function is indicated in the supplied product information. A switched fused connection unit provides local switching and fuse-based overcurrent protection. Where RCD protection is required, it must be provided separately through a suitable distribution-board device or another approved protective arrangement.
Before installation, verify the accessory dimensions, mounting centres, required box depth, cable entry space and compatibility with the selected flush or surface box. Also confirm conductor sizes, terminal capacity, earthing arrangements and the connected appliance load. Avoid forcing conductors behind the plate, as trapped cables or loose terminals can cause overheating and unreliable operation.
It may be suitable only when the appliance operating current does not exceed the unit rating and the appliance manufacturer permits fused-connection-unit control. Many water heaters and air-conditioning systems require higher-rated double-pole isolators, dedicated circuits or specific isolation arrangements. The equipment nameplate, installation manual and approved electrical drawings must be checked before selection.
A qualified electrician should inspect conductor termination, protective-earth continuity, polarity, insulation resistance and circuit protective-device coordination. The switch and connected appliance should then be functionally tested, and terminals should show no signs of looseness or abnormal heating. Testing and documentation should follow the project specification and applicable UAE authority requirements.
Keep the faceplate clean and dry and inspect it periodically for discoloration, cracking, looseness, buzzing, burning smells or excessive heat. If the fuse operates repeatedly, do not fit a higher-rated fuse; isolate the circuit and have the appliance, cable and connections investigated by a qualified electrician. Replace damaged accessories rather than attempting temporary repairs.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy