ABB Inora 1 Gang 13A Switched Fused Connection Unit with Illumination Royal Gold BL507-PG
FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- The 13A fuse protects a fixed appliance feed.
- A local switch controls the fused appliance feed.
- A 35 mm flush box supports concealed fitting.
- Illumination helps locate the control at night.
- BS fused-unit standards support safe installation.
- Royal Gold finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
13A Switched Fused Connection Unit with Illumination from the ABB Inora wiring-accessory range.
Model
BL507-PG identifies the royal gold finish variant.
Configuration
1 Gang configuration is designed for switched fused fixed-appliance connection.
Electrical Rating
13A at 250V AC supports the stated fixed-wiring application.
Indicator
Illuminated provides visible identification or easier location in low light.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 1363-4; SS 403 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in Royal Gold suit switched fused fixed-appliance connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
Royal Gold
Quantity Unit
PCS
Model No
BL507-PG
Brands
ABB
Item Type
Fused Connection Unit
Number of Gang
1 Gang
Rated Current
13A
Rated Voltage
250V AC
Switch Type
Switched
Usage
Switched fused fixed-appliance connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora BL507-PG 13A Switched Fused Connection Unit with LED?
The ABB Inora BL507-PG is a switched fused connection unit designed to provide local isolation and fused protection for a permanently connected electrical appliance or fixed load. It has a rated capacity of 13A, an integrated switch, an LED status indicator and a Royal Gold finish suitable for coordinated residential and commercial interiors.
What is a 13A switched fused connection unit used for?
A 13A switched fused connection unit, commonly called an FCU or fused spur, is used to connect fixed electrical equipment to a final circuit while providing appliance-level fuse protection and a convenient means of switching. Typical applications include water heaters, extractor fans, kitchen hoods, pumps, signage, ventilation equipment and selected air-conditioning accessories, subject to the equipment manufacturer's electrical requirements.
What does the LED indicator on the ABB Inora BL507-PG show?
The LED provides a visible operating-status indication associated with the switched connection. Its exact indication depends on the terminal configuration and wiring arrangement, so the ABB wiring diagram supplied with the product should be followed. The LED is particularly useful where users or maintenance teams need to confirm that a connected appliance has been switched on.
Does this ABB fused connection unit protect the connected appliance?
Yes. The FCU holds a replaceable cartridge fuse that helps protect the connected cable and appliance against overcurrent. The fuse rating must be selected according to the appliance load, cable capacity and manufacturer's instructions and must not exceed the FCU's 13A rating. A smaller fuse may be required for low-power equipment.
Which fuse should be used with the ABB Inora 13A fused spur?
Use a compliant cartridge fuse of the rating specified by the connected equipment manufacturer and the electrical design. For installations based on British wiring accessories, this is normally a BS 1362-type fuse, with 13A being the maximum rating for this FCU. Never replace the fuse with wire, foil or another improvised conductor, and confirm whether a fuse is supplied before installation.
Is the ABB Inora BL507-PG suitable for UAE electrical installations?
It is suited to the 230V, 50Hz low-voltage systems commonly used in the UAE when its complete ABB technical rating and installation conditions match the project specification. Selection and installation should comply with the applicable requirements of the relevant UAE authority, such as DEWA, ADDC, SEWA or the local authority having jurisdiction, together with the project's approved electrical drawings and current wiring regulations.
Can the ABB Royal Gold switched fused connection unit be used in villas, apartments and commercial buildings?
Yes, it can be specified for suitable fixed loads in villas, apartments, hotels, offices, shops and other commercial interiors. The Royal Gold finish makes it especially relevant where electrical accessories must complement premium decorative schemes. For construction projects, designers should confirm the approved accessory range, finish schedule, load rating and back-box compatibility before procurement.
How is the ABB Inora 13A switched fused connection unit installed?
Installation should be completed by a qualified electrician. The circuit must first be safely isolated and verified dead. The supply, load and earth conductors should then be connected to the terminals identified in the ABB wiring diagram, using the specified conductor size and tightening torque. Fit the correctly rated fuse, secure the unit to a compatible electrical box, restore power and test switching, LED operation, polarity, earthing and circuit protection.
Can the BL507-PG fused connection unit be installed as a spur from a ring final circuit?
It may be used as a fused spur where permitted by the circuit design and applicable wiring rules. The electrician must verify the upstream protective device, conductor size, circuit loading, earthing arrangement and number of connected outlets or loads. It should not be treated as a solution for extending a circuit without electrical design checks and testing.
Is this 13A FCU suitable for water heaters or air-conditioning equipment?
It can be used only where the equipment's normal current, starting current and isolation requirements are within the FCU's verified ratings. Some water heaters, pumps and air-conditioning units require a higher-current double-pole isolator or a dedicated circuit instead of a 13A FCU. Always follow the appliance nameplate, manufacturer instructions and approved MEP design.
Can the ABB Inora Royal Gold FCU be installed outdoors or in wet areas?
Do not assume that this decorative indoor wiring accessory is weatherproof. Outdoor, bathroom, wash-area and other damp-location installations require an enclosure and location with an appropriate IP rating, suitable environmental protection and compliance with electrical zoning rules. Confirm the official ABB ingress-protection rating before using it in any exposed or humid location.
What should contractors check before installing the ABB BL507-PG on a construction project?
Contractors should verify the model number BL507-PG, 13A requirement, official voltage rating, fuse type, terminal capacity, mounting box dimensions, plate orientation, Royal Gold finish and compatibility with the specified ABB Inora accessories. They should also check the approved material submittal, MEP drawings, circuit schedule, appliance load and local authority requirements before installation.
What testing is required after fitting the switched fused connection unit?
A qualified electrician should test continuity of protective conductors, insulation resistance, polarity, earth-fault loop performance where applicable, operation of the upstream protective device, switch function and LED indication. The connected load should also be checked under normal operation. Test results should be recorded as part of the project's electrical inspection and commissioning documentation.
How should the ABB Inora Royal Gold fused spur be maintained?
Keep the faceplate clean with a soft, dry or lightly damp cloth and avoid abrasive cleaners, solvents and metal polish unless ABB specifically approves them for the finish. If the fuse repeatedly blows, isolate the circuit and have the appliance, wiring and load inspected by a qualified electrician. Never install a higher-rated fuse merely to prevent repeated operation.
Why choose an ABB Inora 13A switched fused connection unit with LED for UAE projects?
This ABB Inora FCU combines local switching, replaceable fuse protection and visible LED indication in one decorative accessory. Its Royal Gold appearance can suit high-end UAE residential, hospitality and commercial interiors, while the 13A format is relevant to many fixed-appliance connections. Final suitability must be confirmed against the project's electrical load, environmental conditions, authority requirements and approved specifications.
Frequently Asked Questions
The ABB Inora BL507-PG is a switched fused connection unit designed to provide local isolation and fused protection for a permanently connected electrical appliance or fixed load. It has a rated capacity of 13A, an integrated switch, an LED status indicator and a Royal Gold finish suitable for coordinated residential and commercial interiors.
A 13A switched fused connection unit, commonly called an FCU or fused spur, is used to connect fixed electrical equipment to a final circuit while providing appliance-level fuse protection and a convenient means of switching. Typical applications include water heaters, extractor fans, kitchen hoods, pumps, signage, ventilation equipment and selected air-conditioning accessories, subject to the equipment manufacturer's electrical requirements.
The LED provides a visible operating-status indication associated with the switched connection. Its exact indication depends on the terminal configuration and wiring arrangement, so the ABB wiring diagram supplied with the product should be followed. The LED is particularly useful where users or maintenance teams need to confirm that a connected appliance has been switched on.
Yes. The FCU holds a replaceable cartridge fuse that helps protect the connected cable and appliance against overcurrent. The fuse rating must be selected according to the appliance load, cable capacity and manufacturer's instructions and must not exceed the FCU's 13A rating. A smaller fuse may be required for low-power equipment.
Use a compliant cartridge fuse of the rating specified by the connected equipment manufacturer and the electrical design. For installations based on British wiring accessories, this is normally a BS 1362-type fuse, with 13A being the maximum rating for this FCU. Never replace the fuse with wire, foil or another improvised conductor, and confirm whether a fuse is supplied before installation.
It is suited to the 230V, 50Hz low-voltage systems commonly used in the UAE when its complete ABB technical rating and installation conditions match the project specification. Selection and installation should comply with the applicable requirements of the relevant UAE authority, such as DEWA, ADDC, SEWA or the local authority having jurisdiction, together with the project's approved electrical drawings and current wiring regulations.
Yes, it can be specified for suitable fixed loads in villas, apartments, hotels, offices, shops and other commercial interiors. The Royal Gold finish makes it especially relevant where electrical accessories must complement premium decorative schemes. For construction projects, designers should confirm the approved accessory range, finish schedule, load rating and back-box compatibility before procurement.
Installation should be completed by a qualified electrician. The circuit must first be safely isolated and verified dead. The supply, load and earth conductors should then be connected to the terminals identified in the ABB wiring diagram, using the specified conductor size and tightening torque. Fit the correctly rated fuse, secure the unit to a compatible electrical box, restore power and test switching, LED operation, polarity, earthing and circuit protection.
It may be used as a fused spur where permitted by the circuit design and applicable wiring rules. The electrician must verify the upstream protective device, conductor size, circuit loading, earthing arrangement and number of connected outlets or loads. It should not be treated as a solution for extending a circuit without electrical design checks and testing.
It can be used only where the equipment's normal current, starting current and isolation requirements are within the FCU's verified ratings. Some water heaters, pumps and air-conditioning units require a higher-current double-pole isolator or a dedicated circuit instead of a 13A FCU. Always follow the appliance nameplate, manufacturer instructions and approved MEP design.
Do not assume that this decorative indoor wiring accessory is weatherproof. Outdoor, bathroom, wash-area and other damp-location installations require an enclosure and location with an appropriate IP rating, suitable environmental protection and compliance with electrical zoning rules. Confirm the official ABB ingress-protection rating before using it in any exposed or humid location.
Contractors should verify the model number BL507-PG, 13A requirement, official voltage rating, fuse type, terminal capacity, mounting box dimensions, plate orientation, Royal Gold finish and compatibility with the specified ABB Inora accessories. They should also check the approved material submittal, MEP drawings, circuit schedule, appliance load and local authority requirements before installation.
A qualified electrician should test continuity of protective conductors, insulation resistance, polarity, earth-fault loop performance where applicable, operation of the upstream protective device, switch function and LED indication. The connected load should also be checked under normal operation. Test results should be recorded as part of the project's electrical inspection and commissioning documentation.
Keep the faceplate clean with a soft, dry or lightly damp cloth and avoid abrasive cleaners, solvents and metal polish unless ABB specifically approves them for the finish. If the fuse repeatedly blows, isolate the circuit and have the appliance, wiring and load inspected by a qualified electrician. Never install a higher-rated fuse merely to prevent repeated operation.
This ABB Inora FCU combines local switching, replaceable fuse protection and visible LED indication in one decorative accessory. Its Royal Gold appearance can suit high-end UAE residential, hospitality and commercial interiors, while the 13A format is relevant to many fixed-appliance connections. Final suitability must be confirmed against the project's electrical load, environmental conditions, authority requirements and approved specifications.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
