ABB

ABB Inora 1 Gang 13A Unswitched Fused Connection Unit Royal Gold BL506-PG

In Stock
25.95
EXCL.VAT
Incl. 5% VAT AED 27.25

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • The 13A fuse protects a fixed appliance feed.
    • Unswitched output suits permanent connections.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • BS fused-unit standards support safe installation.
    • Royal Gold finish suits coordinated interiors.

Features & Benefits

Product Type

13A Unswitched Fused Connection Unit from the ABB Inora wiring-accessory range.

Model

BL506-PG identifies the royal gold finish variant.

Configuration

1 Gang configuration is designed for fused fixed-appliance connection.

Electrical Rating

13A at 250V AC supports the stated fixed-wiring application.

Installation

Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 1363-4; SS 403 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in Royal Gold suit fused fixed-appliance connection in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

Royal Gold

Quantity Unit

PCS

Model No

BL506-PG

Brands

ABB

Item Type

Fused Connection Unit

Number of Gang

1 Gang

Rated Current

13A

Rated Voltage

250V AC

Switch Type

Unswitched

Usage

Fused fixed-appliance connection

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL506-PG is a 13A unswitched fused connection unit designed to provide a protected connection between a fixed electrical circuit and compatible equipment. It incorporates fuse protection but does not have an on/off rocker switch. Its Royal Gold finish makes it suitable for residential, hospitality and premium commercial interiors where electrical accessories must coordinate with the surrounding décor.

An unswitched fused connection unit, commonly called an unswitched FCU or fused spur, is used to connect fixed or permanently wired appliances while providing local overcurrent protection through a replaceable fuse. Typical applications may include water heaters, ventilation equipment, access-control systems, signage and selected kitchen or building-services equipment, subject to the appliance load, manufacturer instructions and approved electrical design.

The BL506-PG is rated at 13A. The connected load must remain within the unit's rating, the circuit design limits and the appliance manufacturer's requirements. The fitted fuse should be correctly selected for the appliance and cable rather than automatically using the maximum fuse rating. A qualified electrician should confirm voltage compatibility, conductor size, protective device coordination and earthing before installation.

Unswitched means the connection unit has no local rocker switch for manually turning the connected equipment on or off. The appliance remains supplied whenever the upstream circuit is energised, subject to the fuse and other protective devices. If local functional switching or isolation is required, the electrician should specify a suitable switched FCU or separate isolator based on the equipment and applicable regulations.

Yes, it can be considered for residential, commercial, hospitality and fit-out MEP projects where a 13A unswitched fused connection is specified. The project consultant or contractor should verify the product submittal against the approved drawings, load schedule, equipment requirements and the regulations of the relevant UAE authority, such as DEWA or the applicable local electricity and building authority.

Installation should be completed by a licensed electrician. The circuit must first be isolated, locked out where required and tested to confirm it is dead. The electrician should use a compatible wall box, terminate line, neutral and earth conductors at the correctly identified terminals, tighten connections to the manufacturer's specified torque, fit the appropriate fuse, secure the faceplate without overtightening and carry out continuity, insulation, polarity, earthing and functional tests before energising.

It may be used as a fused spur where the circuit arrangement and local regulations permit. Whether it is supplied from a ring final circuit, radial circuit or dedicated circuit depends on the electrical design, connected load, cable size and upstream protection. The installer must follow the approved project drawings and applicable UAE wiring requirements rather than selecting the circuit arrangement solely from the FCU's 13A rating.

Use only a fuse type and rating approved for the unit and suitable for the connected appliance. In British-style fused connection units, a compliant cartridge fuse such as a BS 1362 type is commonly specified, but this should be confirmed from ABB documentation and project requirements. The fuse rating must protect the appliance flex and equipment; fitting a higher-rated fuse than required can reduce protection.

It can be used indoors in kitchens, utility rooms and similar areas when installed in an appropriate location and used with compatible equipment. It should not be exposed directly to water, excessive condensation, grease, heat or harsh cleaning chemicals unless its verified enclosure protection and installation method permit such conditions. UAE project specifications may require additional protection or a suitably rated accessory near sinks and wet zones.

Suitability depends on the equipment's rated current, starting current, isolation requirements and manufacturer instructions. Some small water heaters or controls may be compatible with a 13A FCU, while larger heaters and air-conditioning equipment usually require a dedicated circuit and appropriately rated double-pole isolator. An MEP engineer or licensed electrician should verify the load before selecting this product.

The fuse can be removed after the upstream supply has been safely isolated, but an unswitched FCU should not automatically be treated as the required local isolating device. Where maintenance isolation is necessary, the electrical design may require a switched double-pole FCU or a separate isolator with the correct rating and contact arrangement. Follow the connected equipment instructions and relevant UAE authority requirements.

Use a compatible flush or surface-mounted box that matches the accessory format and provides sufficient depth for the terminals, cable bend radius and conductor arrangement. Box dimensions and minimum depth should be checked against the current ABB Inora technical datasheet before procurement. On construction projects, coordinate box installation with blockwork, drywall, tiling and final finished-wall levels so the faceplate sits securely and evenly.

Keep the faceplate covered during painting, plastering, grouting and other dusty construction work. Clean it with a soft, dry or lightly damp microfibre cloth after isolating the circuit. Avoid abrasive pads, solvent-based cleaners, acidic chemicals and strong detergents because they may damage or discolour the decorative finish. The protective packaging should preferably remain in place until final fixing.

The electrician should verify terminal tightness, protective-conductor continuity, insulation resistance, polarity, earth-fault protection and coordination with the upstream protective device. The correct fuse rating and appliance operation should also be confirmed. For UAE construction projects, test results should be recorded in the relevant inspection and testing documentation and submitted for consultant or authority approval when required.

The ABB Inora BL506-PG combines a functional 13A fused connection point with a decorative Royal Gold appearance. It is particularly relevant to UAE villas, apartments, hotels, offices and retail fit-outs where coordinated premium finishes are specified. Buyers should match it with compatible ABB Inora accessories and confirm technical compliance, environmental suitability and consultant approval before bulk ordering.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy