FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- The 13A fuse protects a fixed appliance feed.
- Unswitched output suits permanent connections.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- BS fused-unit standards support safe installation.
- Starry Black finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
13A Unswitched Fused Connection Unit from the ABB Inora wiring-accessory range.
Model
BL506-885 identifies the starry black finish variant.
Configuration
1 Gang configuration is designed for fused fixed-appliance connection.
Electrical Rating
13A at 250V AC supports the stated fixed-wiring application.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 1363-4; SS 403 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in Starry Black suit fused fixed-appliance connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
Starry Black
Quantity Unit
PCS
Model No
BL506-885
Brands
ABB
Item Type
Fused Connection Unit
Number of Gang
1 Gang
Rated Current
13A
Rated Voltage
250V AC
Switch Type
Unswitched
Usage
Fused fixed-appliance connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 13A Unwitched Fused Connection Unit Starry Black BL506-885?
The ABB Inora BL506-885 is a 13A unwitched fused connection unit designed to provide a fixed electrical appliance or circuit with local fuse protection. Its Starry Black finish suits contemporary residential, commercial and hospitality interiors. Because it is unwitched, the connected load is not controlled from the faceplate and must be isolated using the appropriate upstream protective or isolation device.
Where can the ABB Inora 13A fused connection unit be used?
This fused connection unit is suitable for fixed indoor electrical loads that require fused protection, subject to the appliance manufacturer's instructions and the approved electrical design. Typical applications may include kitchen appliances, ventilation equipment, water-heating controls, signage, access-control equipment and other building services. Confirm the connected load, cable size, environmental conditions and isolation requirements before installation.
What is the difference between an unwitched fused connection unit and a switched FCU?
An unwitched FCU provides fuse protection without a front-mounted on/off switch. A switched FCU combines fuse protection with local manual control. The ABB Inora BL506-885 is appropriate where local switching is unnecessary or where isolation is provided elsewhere. It should not be treated as a local isolator unless the complete circuit design and applicable regulations specifically permit that arrangement.
Does the ABB Inora BL506-885 include 13A fuse protection?
The unit is rated as a 13A fused connection unit and is intended for use with a compatible cartridge fuse. The installed fuse rating must be selected according to the connected appliance, cable capacity and manufacturer's instructions; it should not automatically be assumed that every load requires a 13A fuse. Check the supplied product contents and ABB technical documentation to confirm whether a fuse is included.
Can this 13A unwitched fused connection unit be installed on UAE electrical systems?
It can be considered for UAE projects where its technical ratings, certification and application comply with the approved project specification. UAE low-voltage installations commonly operate at 230V and 50Hz on single-phase final circuits, but compatibility must be verified from the ABB datasheet. Installation should follow the latest requirements of the relevant authority, such as DEWA, ADDC or the applicable emirate utility, together with project and fire-safety requirements.
Which standards should be checked for this ABB fused connection unit?
For UAE construction projects, the consultant or electrical contractor should verify the product's declared conformity and test documentation against the project specification. Fused connection units of this type are commonly assessed with reference to BS 1363-4, while the installation must comply with the current local wiring regulations and authority approvals. Always rely on the BL506-885 technical datasheet and certificates rather than appearance or nominal rating alone.
How is the ABB Inora 13A unwitched FCU installed?
Installation must be completed by a qualified electrician with the circuit safely isolated, locked out where required and proven dead. The electrician should use a compatible wall box, identify supply and load conductors, connect line, neutral and earth to the marked terminals, tighten terminals to ABB's specified torque, fit the correctly rated fuse and secure the faceplate without overtightening. Insulation resistance, polarity, earth continuity and functional checks should be completed before energising.
What back box and wiring accessories are required for the BL506-885?
Use a back box and fixing arrangement compatible with the ABB Inora accessory dimensions and the wall construction. Adequate box depth is important to avoid sharp cable bends, trapped insulation or pressure on the terminals. For blockwork, drywall, joinery or decorative wall panels, the contractor should select an approved box, suitable cable entries and appropriate fixings while maintaining earthing and fire-stopping requirements.
Is the Starry Black ABB Inora fused connection unit suitable for construction and fit-out projects?
Yes, the Starry Black finish is well suited to villas, apartments, offices, hotels, retail interiors and premium fit-out projects using dark electrical accessories. Contractors should coordinate the finish with matching ABB Inora switches, sockets and plates and submit samples when consultant approval is required. The product model and colour reference should also be recorded in material schedules to prevent mismatched accessories during installation.
Can the ABB Inora BL506-885 be used outdoors or in wet areas?
Do not assume that this standard decorative FCU is weatherproof. Outdoor, bathroom, wash-area or dusty-site installation requires an enclosure and location with an appropriate IP rating, corrosion resistance and compliance with electrical zoning rules. Check ABB's published IP rating for the exact model and use a suitable weatherproof accessory or enclosure if the environmental exposure exceeds its declared protection.
Can this fused connection unit supply air conditioners, water heaters or other high-load equipment?
Only if the equipment's rated current, starting current and manufacturer instructions are within the FCU, fuse, cable and circuit design limits. Many air conditioners, large water heaters and heavy appliances require dedicated circuits, higher-rated double-pole isolators or other protective devices. A qualified electrical engineer or contractor should calculate the load and confirm the correct method of connection before using a 13A FCU.
What inspections should be carried out before energising the ABB 13A FCU?
The electrician should confirm the model, fuse rating, terminal identification, conductor size, earth connection, cable sheath entry and terminal tightness. Required circuit tests typically include protective-conductor continuity, insulation resistance, polarity and verification of the upstream protective device and RCD or RCBO arrangement where applicable. The faceplate should sit level, remain undamaged and provide safe access for future fuse replacement.
How should the ABB Inora Starry Black fused connection unit be maintained?
Keep the faceplate clean and dry, using a soft cloth without abrasive or aggressive chemical cleaners. If the fuse operates repeatedly, do not replace it with a higher rating; isolate the circuit and have the appliance, wiring and load investigated by a qualified electrician. Periodic inspection should check for heat discolouration, cracking, loose mounting, unusual odour or signs of damaged terminals.
What should UAE contractors verify before ordering the ABB Inora BL506-885?
Verify the exact model number BL506-885, Starry Black finish, 13A unwitched configuration, required quantity and compatibility with the selected Inora accessory range. Also confirm the project-approved material submittal, technical certification, back-box requirements, fuse specification and authority or consultant requirements. This helps ensure consistent finishes and compliant installation across UAE residential and commercial construction projects.
Frequently Asked Questions
The ABB Inora BL506-885 is a 13A unwitched fused connection unit designed to provide a fixed electrical appliance or circuit with local fuse protection. Its Starry Black finish suits contemporary residential, commercial and hospitality interiors. Because it is unwitched, the connected load is not controlled from the faceplate and must be isolated using the appropriate upstream protective or isolation device.
This fused connection unit is suitable for fixed indoor electrical loads that require fused protection, subject to the appliance manufacturer's instructions and the approved electrical design. Typical applications may include kitchen appliances, ventilation equipment, water-heating controls, signage, access-control equipment and other building services. Confirm the connected load, cable size, environmental conditions and isolation requirements before installation.
An unwitched FCU provides fuse protection without a front-mounted on/off switch. A switched FCU combines fuse protection with local manual control. The ABB Inora BL506-885 is appropriate where local switching is unnecessary or where isolation is provided elsewhere. It should not be treated as a local isolator unless the complete circuit design and applicable regulations specifically permit that arrangement.
The unit is rated as a 13A fused connection unit and is intended for use with a compatible cartridge fuse. The installed fuse rating must be selected according to the connected appliance, cable capacity and manufacturer's instructions; it should not automatically be assumed that every load requires a 13A fuse. Check the supplied product contents and ABB technical documentation to confirm whether a fuse is included.
It can be considered for UAE projects where its technical ratings, certification and application comply with the approved project specification. UAE low-voltage installations commonly operate at 230V and 50Hz on single-phase final circuits, but compatibility must be verified from the ABB datasheet. Installation should follow the latest requirements of the relevant authority, such as DEWA, ADDC or the applicable emirate utility, together with project and fire-safety requirements.
For UAE construction projects, the consultant or electrical contractor should verify the product's declared conformity and test documentation against the project specification. Fused connection units of this type are commonly assessed with reference to BS 1363-4, while the installation must comply with the current local wiring regulations and authority approvals. Always rely on the BL506-885 technical datasheet and certificates rather than appearance or nominal rating alone.
Installation must be completed by a qualified electrician with the circuit safely isolated, locked out where required and proven dead. The electrician should use a compatible wall box, identify supply and load conductors, connect line, neutral and earth to the marked terminals, tighten terminals to ABB's specified torque, fit the correctly rated fuse and secure the faceplate without overtightening. Insulation resistance, polarity, earth continuity and functional checks should be completed before energising.
Use a back box and fixing arrangement compatible with the ABB Inora accessory dimensions and the wall construction. Adequate box depth is important to avoid sharp cable bends, trapped insulation or pressure on the terminals. For blockwork, drywall, joinery or decorative wall panels, the contractor should select an approved box, suitable cable entries and appropriate fixings while maintaining earthing and fire-stopping requirements.
Yes, the Starry Black finish is well suited to villas, apartments, offices, hotels, retail interiors and premium fit-out projects using dark electrical accessories. Contractors should coordinate the finish with matching ABB Inora switches, sockets and plates and submit samples when consultant approval is required. The product model and colour reference should also be recorded in material schedules to prevent mismatched accessories during installation.
Do not assume that this standard decorative FCU is weatherproof. Outdoor, bathroom, wash-area or dusty-site installation requires an enclosure and location with an appropriate IP rating, corrosion resistance and compliance with electrical zoning rules. Check ABB's published IP rating for the exact model and use a suitable weatherproof accessory or enclosure if the environmental exposure exceeds its declared protection.
Only if the equipment's rated current, starting current and manufacturer instructions are within the FCU, fuse, cable and circuit design limits. Many air conditioners, large water heaters and heavy appliances require dedicated circuits, higher-rated double-pole isolators or other protective devices. A qualified electrical engineer or contractor should calculate the load and confirm the correct method of connection before using a 13A FCU.
The electrician should confirm the model, fuse rating, terminal identification, conductor size, earth connection, cable sheath entry and terminal tightness. Required circuit tests typically include protective-conductor continuity, insulation resistance, polarity and verification of the upstream protective device and RCD or RCBO arrangement where applicable. The faceplate should sit level, remain undamaged and provide safe access for future fuse replacement.
Keep the faceplate clean and dry, using a soft cloth without abrasive or aggressive chemical cleaners. If the fuse operates repeatedly, do not replace it with a higher rating; isolate the circuit and have the appliance, wiring and load investigated by a qualified electrician. Periodic inspection should check for heat discolouration, cracking, loose mounting, unusual odour or signs of damaged terminals.
Verify the exact model number BL506-885, Starry Black finish, 13A unwitched configuration, required quantity and compatibility with the selected Inora accessory range. Also confirm the project-approved material submittal, technical certification, back-box requirements, fuse specification and authority or consultant requirements. This helps ensure consistent finishes and compliant installation across UAE residential and commercial construction projects.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy