FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- RJ45 Cat 5E supports structured network links.
- Two-gang layout suits organized cabling.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- The clean faceplate suits modern interiors.
- Classic Grey finish supports coordinated wall fittings.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
2 Gang RJ45 Cat 5E Data Outlet from the ABB Inora wiring-accessory range.
Model
BL332-G identifies the classic grey finish variant.
Configuration
2 Gang configuration is designed for ethernet network connections.
Connector Type
RJ45 Cat 5E provides the stated communication or signal interface.
Installation
Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 5733 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in Classic Grey suit ethernet network connections in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
Classic Grey
Quantity Unit
PCS
Model No
BL332-G
Brands
ABB
Item Type
Data Socket
Number of Gang
2 Gang
Connector Type
RJ45 Cat 5E
Dimension
86 x 38.8 x 86 mm
Height
86 mm
Width
38.8 mm
Depth
86 mm
Usage
Ethernet Network Connections
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 2 Gang CAT.5e Data Socket Classic Grey BL332-G?
The ABB Inora BL332-G is a two-gang CAT.5e data socket designed to provide two wired Ethernet connection points in a single wall outlet. Finished in classic grey, it is suitable for structured cabling installations in UAE homes, offices, shops, hotels and other commercial or residential buildings. It is a passive network termination accessory and must be connected to compatible CAT.5e cabling and network equipment.
What network speed can the ABB Inora CAT.5e data socket support?
When correctly terminated as part of a compliant Category 5e channel, the socket can support Ethernet applications up to 1 Gigabit per second, including 10BASE-T, 100BASE-TX and 1000BASE-T. Actual performance depends on cable quality, total channel length, termination workmanship, patch cords and connected network devices.
Can the BL332-G data socket be used with CAT.6 network cable?
A CAT.6 cable may be physically connected if the conductor size and termination format are compatible, but the completed link will generally be limited by the lowest-category component, which is CAT.5e in this case. For a certified CAT.6 installation, use CAT.6-rated sockets, cable, patch panels and patch cords throughout the channel.
How is the ABB Inora 2 Gang CAT.5e data socket installed?
The socket should be mounted in a compatible wall box or containment system and terminated using the wiring guide marked on the data module. Route the network cables into the box without sharp bends, maintain the pair twists as close as possible to the termination points, secure the conductors with the appropriate IDC termination tool where required, and fit the socket plate squarely to the wall. Installation and testing should be performed by a qualified ELV or structured-cabling technician.
Should T568A or T568B wiring be used with this CAT.5e socket?
Either T568A or T568B may be used if supported by the terminal colour code, but the same wiring scheme must be maintained at both ends of each permanent link. T568B is common in many commercial installations, while project specifications may require a particular scheme. Mixing T568A and T568B unintentionally can create a crossover connection and cause testing or network issues.
What cable length is recommended for a CAT.5e installation using this socket?
For standards-based Ethernet cabling, the permanent link is normally limited to 90 metres, with the complete channel limited to 100 metres including patch cords. Cable routing, bend radius, termination quality and separation from electrical services must also meet the project specification and applicable structured-cabling standards.
Is the ABB Inora BL332-G suitable for UAE residential and commercial projects?
Yes, it is suitable for indoor structured-cabling applications commonly required in UAE villas, apartments, offices, retail spaces, schools and hospitality projects. Its two data outlets help serve locations that require multiple wired connections, such as workstations, television areas, reception desks and meeting rooms. Compatibility with the specified back box, faceplate system and project-approved materials should be confirmed before installation.
Can this two-gang data socket be installed near an electrical power outlet?
It may be positioned in the same user area as power outlets, but data cabling should be segregated from mains wiring in accordance with the project design, local authority requirements and relevant electrical and structured-cabling practices. Use suitable compartmented trunking or separate conduits where required, avoid long parallel runs beside power cables, and cross power cables at approximately 90 degrees when unavoidable.
Is the ABB Inora CAT.5e socket suitable for PoE devices?
A properly installed CAT.5e link can carry Power over Ethernet for compatible devices such as IP phones, wireless access points and some CCTV cameras. PoE performance depends on the complete cabling channel, conductor quality, termination integrity, cable bundle size and the power level required by the device. The installer should confirm that all components meet the applicable PoE and project requirements.
Can the BL332-G be used for CCTV and IP camera installations?
Yes, it can form part of a CAT.5e network connection for IP CCTV cameras, network video equipment and monitoring workstations. For camera locations, ensure that the cable distance is within Ethernet limits and that any PoE requirements are supported by the complete link. This indoor wall socket should not be placed in exposed outdoor or wet locations unless protected by a suitable weather-resistant enclosure.
What tests should be completed after installing the ABB CAT.5e data socket?
Each outlet should be checked for correct wire map, continuity, pair sequence, shorts, opens, split pairs and link length. On professional construction projects, a calibrated cable certifier should be used to verify CAT.5e performance parameters and produce test reports for handover. Both ports should also be clearly labelled to match the corresponding patch-panel positions.
What installation practices help maintain CAT.5e network performance?
Use genuine solid-conductor CAT.5e installation cable from a suitable source, avoid excessive pulling tension, do not crush the cable with ties or clips, maintain the manufacturer's minimum bend radius, and keep pair untwisting at the termination to a minimum. Data cables should also be kept away from high-current circuits, motors, transformers and other sources of electromagnetic interference.
Does the ABB Inora 2 Gang CAT.5e data socket require electrical power?
No. The socket is a passive structured-cabling component and does not require a separate electrical supply. It provides the physical termination between fixed network cabling and Ethernet patch cords. Network connectivity is supplied by connected equipment such as a router, switch or patch panel, while PoE power, if used, is delivered through compatible network equipment.
Is the classic grey finish suitable for modern UAE interiors?
The classic grey finish is well suited to contemporary offices, commercial spaces, utility rooms and modern residential interiors where a neutral electrical-accessory colour is preferred. For a coordinated appearance, confirm that adjacent ABB Inora switches, sockets, frames and accessories use the same finish and compatible product range.
What should contractors verify before ordering the ABB Inora BL332-G data socket?
Contractors should verify the model number BL332-G, required outlet quantity, CAT.5e project specification, wall-box and mounting compatibility, available installation depth, cable termination method, colour schedule and indoor environmental conditions. They should also confirm whether the project requires unshielded or shielded cabling, because every component in the channel must match the specified system.
Frequently Asked Questions
The ABB Inora BL332-G is a two-gang CAT.5e data socket designed to provide two wired Ethernet connection points in a single wall outlet. Finished in classic grey, it is suitable for structured cabling installations in UAE homes, offices, shops, hotels and other commercial or residential buildings. It is a passive network termination accessory and must be connected to compatible CAT.5e cabling and network equipment.
When correctly terminated as part of a compliant Category 5e channel, the socket can support Ethernet applications up to 1 Gigabit per second, including 10BASE-T, 100BASE-TX and 1000BASE-T. Actual performance depends on cable quality, total channel length, termination workmanship, patch cords and connected network devices.
A CAT.6 cable may be physically connected if the conductor size and termination format are compatible, but the completed link will generally be limited by the lowest-category component, which is CAT.5e in this case. For a certified CAT.6 installation, use CAT.6-rated sockets, cable, patch panels and patch cords throughout the channel.
The socket should be mounted in a compatible wall box or containment system and terminated using the wiring guide marked on the data module. Route the network cables into the box without sharp bends, maintain the pair twists as close as possible to the termination points, secure the conductors with the appropriate IDC termination tool where required, and fit the socket plate squarely to the wall. Installation and testing should be performed by a qualified ELV or structured-cabling technician.
Either T568A or T568B may be used if supported by the terminal colour code, but the same wiring scheme must be maintained at both ends of each permanent link. T568B is common in many commercial installations, while project specifications may require a particular scheme. Mixing T568A and T568B unintentionally can create a crossover connection and cause testing or network issues.
For standards-based Ethernet cabling, the permanent link is normally limited to 90 metres, with the complete channel limited to 100 metres including patch cords. Cable routing, bend radius, termination quality and separation from electrical services must also meet the project specification and applicable structured-cabling standards.
Yes, it is suitable for indoor structured-cabling applications commonly required in UAE villas, apartments, offices, retail spaces, schools and hospitality projects. Its two data outlets help serve locations that require multiple wired connections, such as workstations, television areas, reception desks and meeting rooms. Compatibility with the specified back box, faceplate system and project-approved materials should be confirmed before installation.
It may be positioned in the same user area as power outlets, but data cabling should be segregated from mains wiring in accordance with the project design, local authority requirements and relevant electrical and structured-cabling practices. Use suitable compartmented trunking or separate conduits where required, avoid long parallel runs beside power cables, and cross power cables at approximately 90 degrees when unavoidable.
A properly installed CAT.5e link can carry Power over Ethernet for compatible devices such as IP phones, wireless access points and some CCTV cameras. PoE performance depends on the complete cabling channel, conductor quality, termination integrity, cable bundle size and the power level required by the device. The installer should confirm that all components meet the applicable PoE and project requirements.
Yes, it can form part of a CAT.5e network connection for IP CCTV cameras, network video equipment and monitoring workstations. For camera locations, ensure that the cable distance is within Ethernet limits and that any PoE requirements are supported by the complete link. This indoor wall socket should not be placed in exposed outdoor or wet locations unless protected by a suitable weather-resistant enclosure.
Each outlet should be checked for correct wire map, continuity, pair sequence, shorts, opens, split pairs and link length. On professional construction projects, a calibrated cable certifier should be used to verify CAT.5e performance parameters and produce test reports for handover. Both ports should also be clearly labelled to match the corresponding patch-panel positions.
Use genuine solid-conductor CAT.5e installation cable from a suitable source, avoid excessive pulling tension, do not crush the cable with ties or clips, maintain the manufacturer's minimum bend radius, and keep pair untwisting at the termination to a minimum. Data cables should also be kept away from high-current circuits, motors, transformers and other sources of electromagnetic interference.
No. The socket is a passive structured-cabling component and does not require a separate electrical supply. It provides the physical termination between fixed network cabling and Ethernet patch cords. Network connectivity is supplied by connected equipment such as a router, switch or patch panel, while PoE power, if used, is delivered through compatible network equipment.
The classic grey finish is well suited to contemporary offices, commercial spaces, utility rooms and modern residential interiors where a neutral electrical-accessory colour is preferred. For a coordinated appearance, confirm that adjacent ABB Inora switches, sockets, frames and accessories use the same finish and compatible product range.
Contractors should verify the model number BL332-G, required outlet quantity, CAT.5e project specification, wall-box and mounting compatibility, available installation depth, cable termination method, colour schedule and indoor environmental conditions. They should also confirm whether the project requires unshielded or shielded cabling, because every component in the channel must match the specified system.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy