FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- RJ45 Cat 6 supports structured network links.
- Two-gang layout suits organized cabling.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- The clean faceplate suits modern interiors.
- Classic Grey finish supports coordinated wall fittings.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
2 Gang RJ45 Cat 6 Data Outlet from the ABB Inora wiring-accessory range.
Model
BL329-G identifies the classic grey finish variant.
Configuration
2 Gang configuration is designed for ethernet network connections.
Connector Type
RJ45 Cat 6 provides the stated communication or signal interface.
Installation
Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 5733 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in Classic Grey suit ethernet network connections in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
Classic Grey
Quantity Unit
PCS
Model No
BL329-G
Brands
ABB
Item Type
Data Socket
Number of Gang
2 Gang
Connector Type
RJ45 Cat 6
Dimension
86 x 38.8 x 86 mm
Height
86 mm
Width
38.8 mm
Depth
86 mm
Usage
Ethernet Network Connections
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 2 Gang CAT.6 Data Socket Classic Grey BL329-G?
The ABB Inora BL329-G is a two-gang Category 6 data socket designed to provide two structured network connection points in one wall outlet. Finished in classic grey, it is suitable for residential, commercial, hospitality and institutional projects where reliable Ethernet connectivity and a coordinated electrical accessory appearance are required.
What network performance can this CAT.6 data socket support?
When installed as part of a fully compliant Category 6 channel, the socket can support Gigabit Ethernet and data frequencies up to 250 MHz. Actual performance depends on the cable, connectors, patch panels, patch cords, termination quality and total channel length. Every component in the link should meet the required CAT.6 specification.
What does the two-gang design mean for network installation?
The two-gang configuration provides two separate data connection points at one location. Each port requires its own dedicated CAT.6 cable run back to the patch panel, network cabinet or designated consolidation point. This arrangement is useful for connecting two computers, a computer and IP telephone, or other compatible network devices without installing separate wall outlets.
Where can the ABB Inora BL329-G data socket be used?
It is suitable for indoor structured cabling installations in UAE villas, apartments, offices, retail outlets, hotels, schools, clinics and other commercial buildings. Typical applications include workstations, smart TVs, routers, IP phones, network printers and compatible IP-based building systems.
How should the ABB Inora CAT.6 data socket be installed?
Installation should be completed by a qualified ELV or structured cabling technician. Route one CAT.6 cable to each outlet, maintain the cable twist as close as possible to the termination point, follow the selected T568A or T568B wiring scheme consistently, secure the conductors with the correct termination tool and fit the socket into a compatible mounting box. Avoid excessive pulling force, sharp bends, crushed cable and tight cable ties.
Should T568A or T568B wiring be used with this CAT.6 socket?
Either T568A or T568B may be used where supported by the installed data module, but the same scheme must be followed at both ends of every permanent cable link. T568B is commonly encountered in structured cabling projects, while project specifications may require a particular scheme. The approved consultant drawings and cabling schedule should always take priority.
What construction provisions are required before installing this data outlet?
During first-fix construction, provide a compatible concealed or surface mounting box, suitable conduit capacity, accessible cable routes and adequate separation from power circuits. During second fix, confirm that plaster, paint and wall finishes are complete and dry before fitting the socket. The box should be level, free from debris and deep enough to accommodate cable bend radius without compressing the termination.
Can CAT.6 data cables be installed in the same conduit as electrical power cables?
Data and power cables should not normally share the same conduit or compartment unless an approved segregated system is specifically designed for that purpose. Proper separation helps reduce electromagnetic interference and supports electrical safety. Installers should follow the project specification, applicable UAE authority requirements and recognized structured cabling practices.
Is the ABB Inora BL329-G suitable for UAE construction projects?
Yes, it is relevant to UAE residential and commercial projects requiring organized CAT.6 network outlets and a durable, professional wall finish. Selection and installation should comply with the approved project specification, consultant requirements, applicable local authority regulations and recognized standards such as ISO/IEC 11801 or ANSI/TIA-568 where specified.
Can this CAT.6 data socket support Power over Ethernet devices?
The outlet may form part of a Power over Ethernet link when all channel components are correctly rated and the complete installation meets the required Ethernet and PoE specification. Suitability depends on the installed cable, connector rating, patch panel, network switch, device power demand, cable bundling and ambient temperature. Confirm these requirements with the project’s ELV designer or network engineer.
How should the completed CAT.6 outlet be tested?
Each port should be identified and tested after termination. Basic wire-map testing checks continuity, pair order, opens, shorts and split pairs. For projects requiring certified CAT.6 performance, use a calibrated cable certification tester to verify parameters such as insertion loss, return loss, near-end crosstalk and link length. Test reports should be retained as part of the project handover documentation.
What cable length limits apply to a CAT.6 network link?
A standard copper Ethernet channel is generally limited to 100 metres, typically comprising up to 90 metres of permanent horizontal cable plus patch cords at both ends. Project design, PoE load, ambient temperature and cable bundling can affect installation requirements, so the structured cabling design should be reviewed before long cable runs are installed.
Is the classic grey finish suitable for modern UAE interiors?
The classic grey finish works well with contemporary offices, industrial-style interiors, utility areas and coordinated grey electrical accessories. Before ordering for a large project, confirm the colour and accessory range against the approved interior finish schedule, as screen displays and lighting conditions can affect how the shade appears.
Can the ABB Inora 2 Gang CAT.6 Data Socket be installed outdoors?
This wall socket is primarily intended for protected indoor locations. For balconies, gardens, external service areas or other locations exposed to dust, moisture, condensation, heat or direct sunlight, use a suitably rated weatherproof enclosure and outdoor-rated cabling system selected by a qualified engineer. The required IP rating should match the site conditions and UAE project specification.
How can reliable CAT.6 performance be maintained after installation?
Use certified CAT.6 patch cords, keep ports clean and dry, avoid pulling or sharply bending connected leads and clearly label both outlets. Do not paint over the socket or insert damaged plugs. If connection speed becomes unstable, inspect the patch cords first and then have the permanent link retested by a structured cabling technician.
Frequently Asked Questions
The ABB Inora BL329-G is a two-gang Category 6 data socket designed to provide two structured network connection points in one wall outlet. Finished in classic grey, it is suitable for residential, commercial, hospitality and institutional projects where reliable Ethernet connectivity and a coordinated electrical accessory appearance are required.
When installed as part of a fully compliant Category 6 channel, the socket can support Gigabit Ethernet and data frequencies up to 250 MHz. Actual performance depends on the cable, connectors, patch panels, patch cords, termination quality and total channel length. Every component in the link should meet the required CAT.6 specification.
The two-gang configuration provides two separate data connection points at one location. Each port requires its own dedicated CAT.6 cable run back to the patch panel, network cabinet or designated consolidation point. This arrangement is useful for connecting two computers, a computer and IP telephone, or other compatible network devices without installing separate wall outlets.
It is suitable for indoor structured cabling installations in UAE villas, apartments, offices, retail outlets, hotels, schools, clinics and other commercial buildings. Typical applications include workstations, smart TVs, routers, IP phones, network printers and compatible IP-based building systems.
Installation should be completed by a qualified ELV or structured cabling technician. Route one CAT.6 cable to each outlet, maintain the cable twist as close as possible to the termination point, follow the selected T568A or T568B wiring scheme consistently, secure the conductors with the correct termination tool and fit the socket into a compatible mounting box. Avoid excessive pulling force, sharp bends, crushed cable and tight cable ties.
Either T568A or T568B may be used where supported by the installed data module, but the same scheme must be followed at both ends of every permanent cable link. T568B is commonly encountered in structured cabling projects, while project specifications may require a particular scheme. The approved consultant drawings and cabling schedule should always take priority.
During first-fix construction, provide a compatible concealed or surface mounting box, suitable conduit capacity, accessible cable routes and adequate separation from power circuits. During second fix, confirm that plaster, paint and wall finishes are complete and dry before fitting the socket. The box should be level, free from debris and deep enough to accommodate cable bend radius without compressing the termination.
Data and power cables should not normally share the same conduit or compartment unless an approved segregated system is specifically designed for that purpose. Proper separation helps reduce electromagnetic interference and supports electrical safety. Installers should follow the project specification, applicable UAE authority requirements and recognized structured cabling practices.
Yes, it is relevant to UAE residential and commercial projects requiring organized CAT.6 network outlets and a durable, professional wall finish. Selection and installation should comply with the approved project specification, consultant requirements, applicable local authority regulations and recognized standards such as ISO/IEC 11801 or ANSI/TIA-568 where specified.
The outlet may form part of a Power over Ethernet link when all channel components are correctly rated and the complete installation meets the required Ethernet and PoE specification. Suitability depends on the installed cable, connector rating, patch panel, network switch, device power demand, cable bundling and ambient temperature. Confirm these requirements with the project’s ELV designer or network engineer.
Each port should be identified and tested after termination. Basic wire-map testing checks continuity, pair order, opens, shorts and split pairs. For projects requiring certified CAT.6 performance, use a calibrated cable certification tester to verify parameters such as insertion loss, return loss, near-end crosstalk and link length. Test reports should be retained as part of the project handover documentation.
A standard copper Ethernet channel is generally limited to 100 metres, typically comprising up to 90 metres of permanent horizontal cable plus patch cords at both ends. Project design, PoE load, ambient temperature and cable bundling can affect installation requirements, so the structured cabling design should be reviewed before long cable runs are installed.
The classic grey finish works well with contemporary offices, industrial-style interiors, utility areas and coordinated grey electrical accessories. Before ordering for a large project, confirm the colour and accessory range against the approved interior finish schedule, as screen displays and lighting conditions can affect how the shade appears.
This wall socket is primarily intended for protected indoor locations. For balconies, gardens, external service areas or other locations exposed to dust, moisture, condensation, heat or direct sunlight, use a suitably rated weatherproof enclosure and outdoor-rated cabling system selected by a qualified engineer. The required IP rating should match the site conditions and UAE project specification.
Use certified CAT.6 patch cords, keep ports clean and dry, avoid pulling or sharply bending connected leads and clearly label both outlets. Do not paint over the socket or insert damaged plugs. If connection speed becomes unstable, inspect the patch cords first and then have the permanent link retested by a structured cabling technician.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
