ABB

ABB Inora 2 Gang RJ45 Cat 6 Data Outlet Royal Gold BL329-PG

In Stock
71.44
EXCL.VAT
Incl. 5% VAT AED 75.01

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • RJ45 Cat 6 supports structured network links.
    • Two-gang layout suits organized cabling.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • The clean faceplate suits modern interiors.
    • Royal Gold finish supports coordinated wall fittings.

Features & Benefits

Product Type

2 Gang RJ45 Cat 6 Data Outlet from the ABB Inora wiring-accessory range.

Model

BL329-PG identifies the royal gold finish variant.

Configuration

2 Gang configuration is designed for ethernet network connections.

Connector Type

RJ45 Cat 6 provides the stated communication or signal interface.

Installation

Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 5733 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in Royal Gold suit ethernet network connections in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

Royal Gold

Quantity Unit

PCS

Model No

BL329-PG

Brands

ABB

Item Type

Data Socket

Number of Gang

2 Gang

Connector Type

RJ45 Cat 6

Dimension

86 x 38.8 x 86 mm

Height

86 mm

Width

38.8 mm

Depth

86 mm

Usage

Ethernet Network Connections

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL329-PG is a two-outlet CAT.6 data socket designed to provide two wired network connection points from one wall location. Its Royal Gold finish suits premium residential, hospitality, office and commercial interiors, while the CAT.6 rating supports structured Ethernet cabling when installed with compatible CAT.6 cable, connectors and patch panels.

In a correctly designed CAT.6 permanent link or channel, the socket can support Gigabit Ethernet at distances up to 100 metres, subject to the cable type, patch cords, termination quality and network equipment. CAT.6 may also support 10 Gigabit Ethernet over shorter distances under suitable installation conditions, but the complete cabling channel must meet the applicable performance requirements.

For this data-socket model, 2 gang indicates two data connection positions at one wall point, allowing two compatible network devices or two separate data runs to be connected. Before ordering for a project, confirm the port layout, module configuration and included accessories against the approved ABB model BL329-PG submittal or project schedule.

It is suitable for indoor structured-cabling points in villas, apartments, offices, hotels, meeting rooms, retail units, reception areas and other commercial buildings. Typical connections include computers, smart TVs, IP telephones, printers, wireless access points, CCTV network equipment and other Ethernet-enabled devices. Any connected equipment must be compatible with the network design and available PoE standard where applicable.

Installation should be completed by a qualified ELV or structured-cabling technician. The installer should route the specified CAT.6 cable to the outlet box, preserve pair twists close to each termination, terminate both ends to the same T568A or T568B wiring scheme, secure the modules without crushing or sharply bending the cable, fit the Royal Gold faceplate and label each port. The completed links should then be tested and documented with a calibrated cable certifier.

Use project-approved CAT.6 cable with the correct conductor type, impedance, fire-performance classification and shielding arrangement for the installation. Solid-conductor cable is normally used for permanent in-wall links, while compatible stranded patch cords are used between the outlet and device. Mixing lower-category components can reduce the performance of the complete channel.

Avoid excessive pulling tension, tight cable ties, crushed cable, sharp bends and unnecessary untwisting of conductor pairs. Keep data cables separated from power cables and sources of electromagnetic interference in accordance with the project specification and applicable regulations. Correct containment, bend radius, termination, earthing of shielded systems where specified, port labelling and post-installation certification are essential for reliable performance.

Yes, it is relevant to UAE villas, apartments, hotels, offices and premium fit-out projects that require wired data points with a decorative Royal Gold finish. Acceptance depends on the consultant-approved material schedule, project specifications and requirements of the relevant UAE authority or developer. Contractors should submit the exact model number, technical data, samples and compliance documents when approval is required.

The complete structured-cabling installation should follow the project specification and applicable editions of standards such as ISO/IEC 11801, ANSI/TIA-568 and relevant connector requirements under IEC 60603-7. UAE authority, developer, telecom-provider and consultant requirements may also apply. Compliance is determined by the entire installed link, not by the wall socket alone.

A correctly terminated CAT.6 channel can carry Power over Ethernet when the cable, connectors, patch panels and network switch are rated for the required IEEE PoE application. The designer must consider current capacity, cable bundling, ambient temperature and heat rise, especially in UAE service spaces. Confirm the socket's exact PoE suitability and the project's power class before installation.

It is primarily intended for protected indoor installations unless ABB documentation states a suitable environmental or IP rating. It should not be exposed directly to rain, dust, condensation, wash-down areas or intense solar heat. For outdoor, plant-room or humid locations, use an appropriately rated enclosure and components selected for the expected UAE temperature, dust and moisture conditions.

Each cable run should be tested from the wall outlet to the corresponding patch-panel port. Basic wire-map testing checks continuity, pair order, opens, shorts and split pairs, while CAT.6 certification testing verifies parameters such as insertion loss, return loss and crosstalk. Test reports, outlet labels and as-built port schedules should be included in the project handover documentation.

Remove loose dust with a soft, dry cloth and clean the surface using a lightly damp, non-abrasive cloth. Do not use solvents, acidic cleaners, abrasive pads or strong chemicals, as they may damage the Royal Gold finish. Protect the outlet during painting, sanding and wet works, and prevent dust or liquid from entering the data ports.

Verify the model number BL329-PG, Royal Gold colour, two-port configuration, compatible mounting box or support frame, CAT.6 cable system, termination method and any required matching ABB Inora accessories. For construction projects, also compare the item with the approved drawing, data outlet schedule, consultant specification and interior finish sample before procurement.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy