    Key Features

    • RJ45 Cat 6A supports structured network links.
    • Two-gang layout suits organized cabling.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • The clean faceplate suits modern interiors.
    • Royal Gold finish supports coordinated wall fittings.

Features & Benefits

Product Type

2 Gang RJ45 Cat 6A Data Outlet from the ABB Inora wiring-accessory range.

Model

BL317-PG identifies the royal gold finish variant.

Configuration

2 Gang configuration is designed for ethernet network connections.

Connector Type

RJ45 Cat 6A provides the stated communication or signal interface.

Installation

Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 5733 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in Royal Gold suit ethernet network connections in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

Royal Gold

Quantity Unit

PCS

Model No

BL317-PG

Brands

ABB

Item Type

Data Socket

Number of Gang

2 Gang

Connector Type

RJ45 Cat 6A

Dimension

86 x 38.8 x 86 mm

Height

86 mm

Width

38.8 mm

Depth

86 mm

Usage

Ethernet Network Connections

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL317-PG is a two-gang CAT.6a data socket designed to provide two structured network connection points in a single wall outlet. It combines CAT.6a network connectivity with a royal gold finish, making it suitable for residential, commercial, hospitality and premium interior projects where both data performance and appearance are important.

CAT.6a structured cabling is designed for frequencies up to 500 MHz and can support 10 Gigabit Ethernet over a compliant permanent link or channel of up to 100 metres. Actual performance depends on using compatible CAT.6a cable, connectors, patch panels and patch cords, as well as correct termination, separation and testing throughout the installation.

The two-gang configuration provides space for two network outlets at one location. This is useful where separate data connections are required for devices such as computers, IP telephones, smart televisions, wireless access points, network printers or building-management equipment. The exact outlet and module arrangement should be checked against the approved project schedule before installation.

This socket is suitable for villas, apartments, offices, hotels, meeting rooms, reception areas, retail spaces and other indoor structured-cabling applications. Its royal gold finish is particularly relevant to premium interiors where data outlets need to coordinate with decorative switches, sockets and room finishes.

Installation should be completed by a qualified electrician or ELV technician. The installer should isolate nearby electrical circuits where applicable, confirm the wall box and module compatibility, route the CAT.6a cables without sharp bends or excessive pulling tension, terminate each conductor according to the selected T568A or T568B scheme, secure the assembly and fit the front plate. Both ends of every link must use the same wiring scheme.

Maintain the cable manufacturer's minimum bend radius, avoid crushing or tightly stapling the cable, preserve pair twists as close as possible to the termination point and keep data cabling appropriately separated from mains power cables. Data cables should also be routed away from transformers, motors, drives and other sources of electromagnetic interference. Avoid excessive cable untwisting and do not exceed the permitted channel length.

Yes. Each installed link should be labelled and tested with a calibrated CAT.6a cable certifier, not only a basic continuity tester. Certification testing can verify wire map, link length, insertion loss, return loss, near-end crosstalk and other performance parameters. Test reports are commonly required for consultant approval, handover documentation and structured-cabling warranties.

The complete structured-cabling system should follow the approved project specification and applicable standards such as ISO/IEC 11801 and ANSI/TIA-568.2-D. UAE installations may also need to comply with requirements issued by the relevant local authority, telecom provider, consultant or building operator. The socket alone does not certify the complete channel; all components and installation workmanship must meet the specified category.

Yes. It can be specified for new buildings, villa construction, office fit-outs, hotel refurbishments and data-network upgrades. During first-fix work, contractors should coordinate conduit routes, back-box positions, cable capacity and separation from power services. During second-fix, the socket should be installed only after confirming the room finish schedule, outlet identification and network point allocation.

A correctly designed CAT.6a channel can carry both data and Power over Ethernet for compatible equipment such as IP cameras, VoIP phones and wireless access points. PoE performance depends on the cable conductor size, connected hardware, bundle conditions, ambient temperature and applicable IEEE PoE class. For high-power PoE installations, the ELV designer should check heat rise, cable grouping and manufacturer compatibility.

The royal gold finish suits luxury villas, hotel rooms, executive offices and decorative commercial interiors commonly specified in the UAE. To preserve its appearance, protect the faceplate during painting, plastering and other construction activities. Clean it with a soft, dry or lightly damp cloth and avoid abrasive pads, solvents and aggressive chemical cleaners.

This type of decorative data socket is generally intended for dry indoor locations unless the approved ABB technical documentation states a suitable outdoor or ingress-protection rating. For balconies, gardens, external walls, plant areas or other exposed UAE environments, use an appropriately IP-rated enclosure and components selected for dust, moisture, UV exposure and high ambient temperatures.

They may physically connect in some systems, but the overall channel will normally be limited by its lowest-category component. To obtain CAT.6a performance, use CAT.6a-rated cable, modules, patch panels and patch cords throughout the link. Contractors should also confirm whether the project requires shielded or unshielded cabling and select matching components accordingly.

Confirm the model number BL317-PG, required quantity, royal gold finish, wall-box compatibility, module arrangement and whether the project uses shielded or unshielded CAT.6a cabling. Buyers should also check the approved ABB Inora accessory schedule so the data socket coordinates with adjacent switches, power sockets, frames and other wiring accessories.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy