FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- RJ45 Cat 6A supports structured network links.
- Two-gang layout suits organized cabling.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- The clean faceplate suits modern interiors.
- White finish supports coordinated wall fittings.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
2 Gang RJ45 Cat 6A Data Outlet from the ABB Inora wiring-accessory range.
Model
BL317 identifies the white finish variant.
Configuration
2 Gang configuration is designed for ethernet network connections.
Connector Type
RJ45 Cat 6A provides the stated communication or signal interface.
Installation
Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 5733 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit ethernet network connections in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL317
Brands
ABB
Item Type
Data Socket
Number of Gang
2 Gang
Connector Type
RJ45 Cat 6A
Dimension
86 x 38.8 x 86 mm
Height
86 mm
Width
38.8 mm
Depth
86 mm
Usage
Ethernet Network Connections
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 2 Gang CAT.6a Data Socket White BL317?
The ABB Inora BL317 is a white, two-gang CAT.6A data socket designed to provide two wired network connection points in residential, commercial and construction projects. It is suitable for structured cabling installations where reliable, high-bandwidth Ethernet connectivity and a neat wall-mounted finish are required.
What network performance can a CAT.6A data socket support?
When installed as part of a fully compliant CAT.6A channel, the socket can support Ethernet speeds of up to 10 Gigabit per second over a maximum channel length of 100 metres. Actual performance depends on the cable, connectors, patch panels, patch cords, termination quality and network equipment used throughout the system.
What does the 2 gang design of the ABB BL317 provide?
The two-gang configuration provides two separate data connection positions at one wall location. This is useful for workstations, meeting rooms, television areas, access-control points and other locations that require two network links, such as separate connections for a computer and an IP telephone.
Where can the ABB Inora CAT.6A data socket be used?
The BL317 is suitable for offices, villas, apartments, hotels, schools, hospitals, retail spaces, server-related areas and other structured cabling applications. It can be specified for new construction, fit-out work or network upgrades where two fixed Ethernet outlets are needed.
How is the ABB Inora BL317 data socket installed?
Installation should be completed by a qualified low-voltage or structured-cabling technician. The installer should route the specified CAT.6A cable to a compatible back box, maintain the cable's minimum bend radius, terminate each outlet according to the selected T568A or T568B wiring scheme, secure the assembly without crushing the cable and fit the faceplate level with the finished wall. The same wiring scheme must be maintained across the project.
Which cable should be used with this CAT.6A data socket?
Use genuine CAT.6A horizontal network cable and compatible CAT.6A components throughout the permanent link. The cable construction, conductor type and shielding arrangement should match the outlet hardware and project specification. Mixing lower-category or incompatible shielded and unshielded components may reduce performance and prevent the installation from achieving CAT.6A certification.
Is the ABB BL317 suitable for concealed installation in UAE construction projects?
It can be used in concealed wall installations when paired with a compatible electrical or data back box and suitable conduit system. Contractors should confirm box dimensions, mounting depth and cable-entry space before installation. Data cabling should be segregated from power wiring in accordance with the project design, applicable UAE authority requirements and recognised structured cabling practices.
Which cabling standards should be followed when installing the BL317?
The complete structured cabling system should be designed and tested in line with the consultant's specification and applicable standards such as ISO/IEC 11801 or ANSI/TIA-568.2-D. UAE projects may also require compliance with local authority regulations, developer guidelines and civil defence or telecom requirements where applicable. Product compatibility should always be checked against the approved material submittal.
Can the ABB Inora CAT.6A socket be used for PoE devices?
A correctly designed CAT.6A structured cabling link can carry data and Power over Ethernet for compatible equipment such as IP cameras, wireless access points and VoIP phones. PoE suitability depends on the complete channel, conductor size, connector rating, cable bundling, ambient temperature and the PoE standard being used. The project engineer should verify these factors, especially in warm UAE service areas.
Why is CAT.6A relevant for offices and smart buildings in the UAE?
CAT.6A is commonly selected for modern UAE offices, smart homes, hospitality developments and commercial fit-outs because it can support high-bandwidth networks and 10 Gigabit Ethernet when installed as a compliant end-to-end system. It also provides useful capacity for access points, building-management devices, IP surveillance and other connected-building applications.
How should CAT.6A cable be terminated to maintain network performance?
Keep the twisted pairs intact as close as possible to the termination point, avoid excessive untwisting, do not kink or sharply bend the cable and prevent overtightening of cable ties. Follow the connector's termination instructions and use the correct punch-down or termination tool. For shielded systems, bonding and earthing must be completed according to the system design and applicable standards.
How should the installed ABB BL317 outlets be tested?
Each installed link should be checked for wire map, continuity, pair faults and correct outlet identification. For contractual CAT.6A compliance, use a calibrated field certification tester to assess the permanent link or channel against the required CAT.6A test limit. Test reports should be labelled by outlet and retained as part of the project's testing and commissioning documentation.
Can this data socket be installed outdoors or in humid locations?
The BL317 is primarily suited to protected indoor locations unless the approved ABB documentation states otherwise. For outdoor, dusty, wet or high-humidity UAE environments, install it inside an appropriately rated enclosure or select a dedicated weather-resistant data outlet. The enclosure's IP rating and material should match the site's exposure conditions.
What should buyers verify before ordering the ABB Inora BL317?
Confirm the model number BL317, white finish, required number of outlets, compatible back-box dimensions and whether the project uses shielded or unshielded CAT.6A cabling. Buyers should also verify compatibility with the selected ABB Inora wiring accessories and ensure that all cables, patch panels, modules and patch cords meet the approved structured cabling specification.
How should the ABB Inora white data socket be maintained?
Keep the faceplate clean and dry, remove dust with a soft cloth and avoid abrasive or solvent-based cleaners. Inspect ports periodically for physical damage, loose mounting or contaminated contacts. Disconnect patch cords by pressing the plug latch rather than pulling the cable, and retest the network link after renovation work or if performance problems occur.
Frequently Asked Questions
The ABB Inora BL317 is a white, two-gang CAT.6A data socket designed to provide two wired network connection points in residential, commercial and construction projects. It is suitable for structured cabling installations where reliable, high-bandwidth Ethernet connectivity and a neat wall-mounted finish are required.
When installed as part of a fully compliant CAT.6A channel, the socket can support Ethernet speeds of up to 10 Gigabit per second over a maximum channel length of 100 metres. Actual performance depends on the cable, connectors, patch panels, patch cords, termination quality and network equipment used throughout the system.
The two-gang configuration provides two separate data connection positions at one wall location. This is useful for workstations, meeting rooms, television areas, access-control points and other locations that require two network links, such as separate connections for a computer and an IP telephone.
The BL317 is suitable for offices, villas, apartments, hotels, schools, hospitals, retail spaces, server-related areas and other structured cabling applications. It can be specified for new construction, fit-out work or network upgrades where two fixed Ethernet outlets are needed.
Installation should be completed by a qualified low-voltage or structured-cabling technician. The installer should route the specified CAT.6A cable to a compatible back box, maintain the cable's minimum bend radius, terminate each outlet according to the selected T568A or T568B wiring scheme, secure the assembly without crushing the cable and fit the faceplate level with the finished wall. The same wiring scheme must be maintained across the project.
Use genuine CAT.6A horizontal network cable and compatible CAT.6A components throughout the permanent link. The cable construction, conductor type and shielding arrangement should match the outlet hardware and project specification. Mixing lower-category or incompatible shielded and unshielded components may reduce performance and prevent the installation from achieving CAT.6A certification.
It can be used in concealed wall installations when paired with a compatible electrical or data back box and suitable conduit system. Contractors should confirm box dimensions, mounting depth and cable-entry space before installation. Data cabling should be segregated from power wiring in accordance with the project design, applicable UAE authority requirements and recognised structured cabling practices.
The complete structured cabling system should be designed and tested in line with the consultant's specification and applicable standards such as ISO/IEC 11801 or ANSI/TIA-568.2-D. UAE projects may also require compliance with local authority regulations, developer guidelines and civil defence or telecom requirements where applicable. Product compatibility should always be checked against the approved material submittal.
A correctly designed CAT.6A structured cabling link can carry data and Power over Ethernet for compatible equipment such as IP cameras, wireless access points and VoIP phones. PoE suitability depends on the complete channel, conductor size, connector rating, cable bundling, ambient temperature and the PoE standard being used. The project engineer should verify these factors, especially in warm UAE service areas.
CAT.6A is commonly selected for modern UAE offices, smart homes, hospitality developments and commercial fit-outs because it can support high-bandwidth networks and 10 Gigabit Ethernet when installed as a compliant end-to-end system. It also provides useful capacity for access points, building-management devices, IP surveillance and other connected-building applications.
Keep the twisted pairs intact as close as possible to the termination point, avoid excessive untwisting, do not kink or sharply bend the cable and prevent overtightening of cable ties. Follow the connector's termination instructions and use the correct punch-down or termination tool. For shielded systems, bonding and earthing must be completed according to the system design and applicable standards.
Each installed link should be checked for wire map, continuity, pair faults and correct outlet identification. For contractual CAT.6A compliance, use a calibrated field certification tester to assess the permanent link or channel against the required CAT.6A test limit. Test reports should be labelled by outlet and retained as part of the project's testing and commissioning documentation.
The BL317 is primarily suited to protected indoor locations unless the approved ABB documentation states otherwise. For outdoor, dusty, wet or high-humidity UAE environments, install it inside an appropriately rated enclosure or select a dedicated weather-resistant data outlet. The enclosure's IP rating and material should match the site's exposure conditions.
Confirm the model number BL317, white finish, required number of outlets, compatible back-box dimensions and whether the project uses shielded or unshielded CAT.6A cabling. Buyers should also verify compatibility with the selected ABB Inora wiring accessories and ensure that all cables, patch panels, modules and patch cords meet the approved structured cabling specification.
Keep the faceplate clean and dry, remove dust with a soft cloth and avoid abrasive or solvent-based cleaners. Inspect ports periodically for physical damage, loose mounting or contaminated contacts. Disconnect patch cords by pressing the plug latch rather than pulling the cable, and retest the network link after renovation work or if performance problems occur.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
