FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- TV and RJ45 Cat 5E support signal and data links.
- Two-gang layout suits organized cabling.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- The clean faceplate suits modern interiors.
- Classic Grey finish supports coordinated wall fittings.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
2 Gang TV and RJ45 Cat 5E Data Outlet from the ABB Inora wiring-accessory range.
Model
BL325-G identifies the classic grey finish variant.
Configuration
2 Gang configuration is designed for tv and ethernet connections.
Signal / Load Rating
5-1000 MHz is specified for the intended connected equipment.
Connector Type
TV coaxial and RJ45 Cat 5E provides the stated communication or signal interface.
Installation
Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 5733 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in Classic Grey suit tv and ethernet connections in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
Classic Grey
Quantity Unit
PCS
Model No
BL325-G
Brands
ABB
Item Type
Data Socket
Number of Gang
2 Gang
Frequency
5-1000 MHz
Connector Type
TV coaxial and RJ45 Cat 5E
Dimension
86 x 38.8 x 86 mm
Height
86 mm
Width
38.8 mm
Depth
86 mm
Usage
TV and Ethernet Connections
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora BL325-G 2 Gang TV/Data Outlet?
The ABB Inora BL325-G is a combined wall outlet designed to provide TV and structured data connectivity from one convenient location. It incorporates a TV connection rated for the 5–1000 MHz frequency range and an RJ45 Category 5e data port. Its Classic Grey finish suits residential, commercial, hospitality and office interiors in the UAE.
What connections does the ABB Inora BL325-G outlet support?
This outlet supports a 5–1000 MHz TV coaxial connection and an RJ45 Cat.5e network connection. The TV section is intended for compatible terrestrial, MATV or cable distribution systems within the stated frequency range, while the data section connects Ethernet devices such as computers, smart TVs, IP phones, access points and network switches.
What network speed can the Cat.5e RJ45 port provide?
A correctly installed Cat.5e structured cabling link can support Ethernet speeds up to 1 Gigabit per second over a standard channel length of up to 100 metres, subject to the connected equipment, cable quality, termination accuracy and network design. The completed link should be tested and certified to the project’s specified cabling standard.
Is the 5–1000 MHz TV outlet suitable for satellite TV systems?
The 5–1000 MHz rating is generally associated with terrestrial TV, cable TV and MATV distribution frequencies. Many satellite intermediate-frequency systems operate above 1000 MHz, so this outlet should not be selected for satellite applications unless the system designer confirms compatibility. Check the headend, receiver and distribution-system frequency requirements before installation.
Where can this combined TV and data outlet be used?
The ABB Inora TV/Data Outlet is suitable for apartments, villas, hotel rooms, offices, meeting rooms, retail units and other indoor areas requiring TV and Ethernet access at the same point. It is especially useful behind televisions, entertainment units, workstations and reception counters, where a neat combined connection reduces the need for separate wall outlets.
How is the ABB Inora BL325-G installed?
Installation should be completed by a qualified low-voltage or structured-cabling technician. Mount the outlet in a compatible wall box and support frame, route the Cat.5e and 75-ohm coaxial cables without sharp bends, terminate each cable using the correct tools and pin configuration, secure the outlet, and fit the Classic Grey faceplate. Test both the data link and TV signal before handover.
Which wiring standard should be used for the RJ45 Cat.5e termination?
Use one consistent RJ45 pinout throughout the link, normally T568A or T568B as specified by the consultant, contractor or existing network. T568B is common in many projects, but it must not be mixed with T568A at the opposite end unless a crossover connection is intentionally required. Installation and testing should follow the approved project specification and applicable ISO/IEC 11801 or ANSI/TIA-568 structured-cabling practices.
What type of cables should be used with this ABB TV and data socket?
Use project-approved Cat.5e cable for the RJ45 data connection and a quality 75-ohm coaxial cable for the TV connection. Cable fire-performance classification, shielding and jacket type should match the building specification and installation area. For UAE construction projects, confirm whether LSZH, flame-retardant or other authority- and consultant-approved cable requirements apply.
What should contractors consider when installing this outlet in UAE buildings?
Contractors should follow the approved shop drawings, local authority requirements, project specifications and the structured-cabling consultant’s instructions. ELV and data cables should be segregated from mains power wiring to reduce interference and meet safe installation practices. In projects regulated by authorities such as DEWA, ADDC or relevant municipal and civil defence bodies, use approved materials and comply with the requirements applicable to the specific building and emirate.
Can the ABB Inora BL325-G be installed during new construction or renovation?
Yes. It can be included in first-fix and second-fix works for new villas, apartments, offices and hospitality projects, or added during renovation where compatible back boxes and cable routes are available. During first fix, provide adequate conduit capacity, cable bend radius and draw wires. During second fix, terminate, label and test the TV and data connections before final acceptance.
Does the RJ45 outlet provide Wi-Fi by itself?
No. The RJ45 Cat.5e port is a passive wired network connection and does not generate a Wi-Fi signal. It must be connected through structured cabling to a network switch, router or patch panel. A compatible wireless access point can then be connected to the outlet if Wi-Fi coverage is required.
How should the TV and data outlet be tested after installation?
Test the Cat.5e link with a suitable cable certifier or network tester to verify wire map, continuity, pair arrangement and link performance. Test the TV connection using an appropriate signal meter to confirm signal level and quality across the required frequencies. Contractors should label the outlet and its corresponding patch-panel or distribution point for easier commissioning and maintenance.
Is this outlet suitable for outdoor or wet-area installation?
This type of decorative TV and data outlet is intended for protected indoor use unless the complete installed assembly has a separately confirmed IP rating. Do not install it in exposed outdoor, high-moisture or wash-down areas without a suitable weatherproof enclosure and consultant approval. UAE heat, dust and humidity conditions make correct environmental protection particularly important.
How can reliable Cat.5e performance be maintained in a construction project?
Avoid crushing, overstretching or tightly bending the data cable, and do not untwist the pairs more than necessary during termination. Maintain separation from power cables, motors and other interference sources, use compatible Cat.5e components throughout the permanent link, and keep the total channel within the applicable length limit. Certification records should be retained as part of the project handover documents.
Why choose the ABB Inora Classic Grey TV/Data Outlet for UAE interiors?
The outlet combines two commonly required ELV services in one organised wall point, helping produce a clean finish in modern UAE homes, offices and hospitality developments. The Classic Grey colour coordinates well with contemporary interior schemes, while the ABB Inora range is suitable for projects where consistent accessory styling and dependable structured connectivity are required.
Frequently Asked Questions
The ABB Inora BL325-G is a combined wall outlet designed to provide TV and structured data connectivity from one convenient location. It incorporates a TV connection rated for the 5–1000 MHz frequency range and an RJ45 Category 5e data port. Its Classic Grey finish suits residential, commercial, hospitality and office interiors in the UAE.
This outlet supports a 5–1000 MHz TV coaxial connection and an RJ45 Cat.5e network connection. The TV section is intended for compatible terrestrial, MATV or cable distribution systems within the stated frequency range, while the data section connects Ethernet devices such as computers, smart TVs, IP phones, access points and network switches.
A correctly installed Cat.5e structured cabling link can support Ethernet speeds up to 1 Gigabit per second over a standard channel length of up to 100 metres, subject to the connected equipment, cable quality, termination accuracy and network design. The completed link should be tested and certified to the project’s specified cabling standard.
The 5–1000 MHz rating is generally associated with terrestrial TV, cable TV and MATV distribution frequencies. Many satellite intermediate-frequency systems operate above 1000 MHz, so this outlet should not be selected for satellite applications unless the system designer confirms compatibility. Check the headend, receiver and distribution-system frequency requirements before installation.
The ABB Inora TV/Data Outlet is suitable for apartments, villas, hotel rooms, offices, meeting rooms, retail units and other indoor areas requiring TV and Ethernet access at the same point. It is especially useful behind televisions, entertainment units, workstations and reception counters, where a neat combined connection reduces the need for separate wall outlets.
Installation should be completed by a qualified low-voltage or structured-cabling technician. Mount the outlet in a compatible wall box and support frame, route the Cat.5e and 75-ohm coaxial cables without sharp bends, terminate each cable using the correct tools and pin configuration, secure the outlet, and fit the Classic Grey faceplate. Test both the data link and TV signal before handover.
Use one consistent RJ45 pinout throughout the link, normally T568A or T568B as specified by the consultant, contractor or existing network. T568B is common in many projects, but it must not be mixed with T568A at the opposite end unless a crossover connection is intentionally required. Installation and testing should follow the approved project specification and applicable ISO/IEC 11801 or ANSI/TIA-568 structured-cabling practices.
Use project-approved Cat.5e cable for the RJ45 data connection and a quality 75-ohm coaxial cable for the TV connection. Cable fire-performance classification, shielding and jacket type should match the building specification and installation area. For UAE construction projects, confirm whether LSZH, flame-retardant or other authority- and consultant-approved cable requirements apply.
Contractors should follow the approved shop drawings, local authority requirements, project specifications and the structured-cabling consultant’s instructions. ELV and data cables should be segregated from mains power wiring to reduce interference and meet safe installation practices. In projects regulated by authorities such as DEWA, ADDC or relevant municipal and civil defence bodies, use approved materials and comply with the requirements applicable to the specific building and emirate.
Yes. It can be included in first-fix and second-fix works for new villas, apartments, offices and hospitality projects, or added during renovation where compatible back boxes and cable routes are available. During first fix, provide adequate conduit capacity, cable bend radius and draw wires. During second fix, terminate, label and test the TV and data connections before final acceptance.
No. The RJ45 Cat.5e port is a passive wired network connection and does not generate a Wi-Fi signal. It must be connected through structured cabling to a network switch, router or patch panel. A compatible wireless access point can then be connected to the outlet if Wi-Fi coverage is required.
Test the Cat.5e link with a suitable cable certifier or network tester to verify wire map, continuity, pair arrangement and link performance. Test the TV connection using an appropriate signal meter to confirm signal level and quality across the required frequencies. Contractors should label the outlet and its corresponding patch-panel or distribution point for easier commissioning and maintenance.
This type of decorative TV and data outlet is intended for protected indoor use unless the complete installed assembly has a separately confirmed IP rating. Do not install it in exposed outdoor, high-moisture or wash-down areas without a suitable weatherproof enclosure and consultant approval. UAE heat, dust and humidity conditions make correct environmental protection particularly important.
Avoid crushing, overstretching or tightly bending the data cable, and do not untwist the pairs more than necessary during termination. Maintain separation from power cables, motors and other interference sources, use compatible Cat.5e components throughout the permanent link, and keep the total channel within the applicable length limit. Certification records should be retained as part of the project handover documents.
The outlet combines two commonly required ELV services in one organised wall point, helping produce a clean finish in modern UAE homes, offices and hospitality developments. The Classic Grey colour coordinates well with contemporary interior schemes, while the ABB Inora range is suitable for projects where consistent accessory styling and dependable structured connectivity are required.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
