- The 20A rating suits fixed appliance feeds.
- The outlet provides a neat flex cable entry point.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- The terminal layout supports organized wiring.
- Classic Grey finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
20A Flex Outlet from the ABB Inora wiring-accessory range.
Model
BL120-G identifies the classic grey finish variant.
Configuration
1 Gang configuration is designed for fixed appliance flex cable connection.
Electrical Rating
20A at 250V AC supports the stated fixed-wiring application.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 5733; MS 1144; MS 1145 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in Classic Grey suit fixed appliance flex cable connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
Classic Grey
Quantity Unit
PCS
Model No
BL120-G
Brands
ABB
Item Type
Terminal Connection Unit
Number of Gang
1 Gang
Rated Current
20A
Rated Voltage
250V AC
Usage
Fixed appliance flex cable connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 20A Flex Outlet Classic Grey BL120-G?
The ABB Inora BL120-G is a 20A flex outlet designed to provide a neat, fixed connection point for the flexible cable of compatible electrical equipment. Finished in Classic Grey, it is suitable for coordinated residential, commercial and construction-project interiors where an ABB Inora wiring accessory is specified.
What is a 20A flex outlet used for?
A 20A flex outlet is commonly used to route and terminate the flexible supply cable of suitable fixed or stationary appliances. Typical applications may include water heaters, ventilation equipment, kitchen appliances and other loads within the outlet and circuit ratings. Appliance load, cable size, protective device and connection method must be confirmed by a qualified electrician.
Is the ABB BL120-G a standard plug socket?
No. It is a flex outlet rather than a conventional socket outlet for a removable plug. It provides a controlled cable exit for equipment connected to the fixed wiring system. If local regulations or the appliance manufacturer require a switch, fused connection unit, isolator or dedicated socket, those devices must be specified separately.
What is the rated current of the ABB Inora BL120-G flex outlet?
The product is identified with a 20A current rating. The connected equipment must not exceed this rating, and the complete circuit—including conductors, terminals, protective device and isolation equipment—must be correctly selected for the actual design load and installation conditions.
Is this flex outlet suitable for UAE electrical installations?
It can be used in UAE projects where its rating, installation method and project specification are compatible with the circuit. UAE low-voltage supplies are generally 230V at 50Hz for single-phase applications, but compliance must be checked against the applicable emirate authority requirements, approved project drawings and relevant wiring regulations before installation.
How should the ABB Inora 20A flex outlet be installed?
Installation should be carried out by a licensed or suitably qualified electrician. The circuit must be safely isolated and verified dead before work begins. The installer should use a compatible mounting box, prepare conductors without damaging them, connect live, neutral and earth as required by the product markings, secure the flexible cable against strain, tighten terminals to ABB's specified torque and refit the cover correctly. The circuit should then be inspected and electrically tested before energisation.
What cable size should be used with the ABB BL120-G?
Cable size cannot be selected from the 20A accessory rating alone. It depends on the connected load, circuit-breaker rating, installation method, ambient temperature, grouping, cable length and permissible voltage drop. A qualified electrical designer or electrician should calculate the required conductor size in accordance with the applicable UAE authority and project requirements.
Does the ABB Inora flex outlet provide appliance isolation or overcurrent protection?
A flex outlet should not be assumed to provide switching, isolation, fusing or circuit protection unless these functions are explicitly stated in ABB's technical documentation. The installation may require a suitably rated double-pole switch, local isolator, fused device, MCB or RCBO depending on the appliance, circuit design and local regulations.
Can the BL120-G be installed in kitchens, bathrooms or outdoor areas?
Use in kitchens, bathrooms, utility areas or outdoor locations depends on environmental conditions and the product's confirmed IP rating. Do not assume that the outlet is waterproof or weatherproof. Installations exposed to moisture, dust, heat or water splashes may require an appropriately rated enclosure, suitable location, RCD or RCBO protection and compliance with relevant electrical zones.
Is the Classic Grey finish suitable for construction and fit-out projects?
Yes. The Classic Grey finish offers a neutral appearance that can coordinate with modern offices, apartments, villas, workshops and commercial fit-outs. Contractors should confirm the finish against approved material submittals, room schedules and other ABB Inora accessories to maintain visual consistency across the project.
What checks should be completed before handing over the installation?
The electrician should check conductor identification, earth continuity, terminal tightness, cable restraint, polarity, insulation resistance and operation of the circuit protection. The faceplate should sit securely and evenly, with no exposed copper or damaged cable. Test results should be recorded where required by the consultant, contractor or relevant UAE authority.
Can the ABB 20A flex outlet be used for an electric water heater?
It may be suitable as the cable outlet component of a correctly designed water-heater circuit, provided the heater load and installation requirements are compatible with its 20A rating. Water heaters commonly require a dedicated circuit and accessible double-pole isolation, and installations near wet areas must follow applicable zoning and protection requirements. Always check the heater manufacturer's instructions and approved electrical design.
What should contractors verify before ordering the ABB Inora BL120-G?
Verify model BL120-G, 20A rating, Classic Grey colour, required quantity, mounting-box compatibility, cable-entry arrangement and coordination with the selected ABB Inora range. Also confirm whether the project requires separate switching, fusing, isolation, protective enclosures or authority-approved documentation.
How should the ABB Inora flex outlet be maintained?
Keep the outlet clean and dry, and do not paint over it or obstruct the cable exit. Periodically check for discoloration, heat damage, looseness, cracking, buzzing or a burning smell. If any defect is found, isolate the circuit and arrange inspection by a qualified electrician; terminals must never be tightened while the circuit is energised.
Frequently Asked Questions
The ABB Inora BL120-G is a 20A flex outlet designed to provide a neat, fixed connection point for the flexible cable of compatible electrical equipment. Finished in Classic Grey, it is suitable for coordinated residential, commercial and construction-project interiors where an ABB Inora wiring accessory is specified.
A 20A flex outlet is commonly used to route and terminate the flexible supply cable of suitable fixed or stationary appliances. Typical applications may include water heaters, ventilation equipment, kitchen appliances and other loads within the outlet and circuit ratings. Appliance load, cable size, protective device and connection method must be confirmed by a qualified electrician.
No. It is a flex outlet rather than a conventional socket outlet for a removable plug. It provides a controlled cable exit for equipment connected to the fixed wiring system. If local regulations or the appliance manufacturer require a switch, fused connection unit, isolator or dedicated socket, those devices must be specified separately.
The product is identified with a 20A current rating. The connected equipment must not exceed this rating, and the complete circuit—including conductors, terminals, protective device and isolation equipment—must be correctly selected for the actual design load and installation conditions.
It can be used in UAE projects where its rating, installation method and project specification are compatible with the circuit. UAE low-voltage supplies are generally 230V at 50Hz for single-phase applications, but compliance must be checked against the applicable emirate authority requirements, approved project drawings and relevant wiring regulations before installation.
Installation should be carried out by a licensed or suitably qualified electrician. The circuit must be safely isolated and verified dead before work begins. The installer should use a compatible mounting box, prepare conductors without damaging them, connect live, neutral and earth as required by the product markings, secure the flexible cable against strain, tighten terminals to ABB's specified torque and refit the cover correctly. The circuit should then be inspected and electrically tested before energisation.
Cable size cannot be selected from the 20A accessory rating alone. It depends on the connected load, circuit-breaker rating, installation method, ambient temperature, grouping, cable length and permissible voltage drop. A qualified electrical designer or electrician should calculate the required conductor size in accordance with the applicable UAE authority and project requirements.
A flex outlet should not be assumed to provide switching, isolation, fusing or circuit protection unless these functions are explicitly stated in ABB's technical documentation. The installation may require a suitably rated double-pole switch, local isolator, fused device, MCB or RCBO depending on the appliance, circuit design and local regulations.
Use in kitchens, bathrooms, utility areas or outdoor locations depends on environmental conditions and the product's confirmed IP rating. Do not assume that the outlet is waterproof or weatherproof. Installations exposed to moisture, dust, heat or water splashes may require an appropriately rated enclosure, suitable location, RCD or RCBO protection and compliance with relevant electrical zones.
Yes. The Classic Grey finish offers a neutral appearance that can coordinate with modern offices, apartments, villas, workshops and commercial fit-outs. Contractors should confirm the finish against approved material submittals, room schedules and other ABB Inora accessories to maintain visual consistency across the project.
The electrician should check conductor identification, earth continuity, terminal tightness, cable restraint, polarity, insulation resistance and operation of the circuit protection. The faceplate should sit securely and evenly, with no exposed copper or damaged cable. Test results should be recorded where required by the consultant, contractor or relevant UAE authority.
It may be suitable as the cable outlet component of a correctly designed water-heater circuit, provided the heater load and installation requirements are compatible with its 20A rating. Water heaters commonly require a dedicated circuit and accessible double-pole isolation, and installations near wet areas must follow applicable zoning and protection requirements. Always check the heater manufacturer's instructions and approved electrical design.
Verify model BL120-G, 20A rating, Classic Grey colour, required quantity, mounting-box compatibility, cable-entry arrangement and coordination with the selected ABB Inora range. Also confirm whether the project requires separate switching, fusing, isolation, protective enclosures or authority-approved documentation.
Keep the outlet clean and dry, and do not paint over it or obstruct the cable exit. Periodically check for discoloration, heat damage, looseness, cracking, buzzing or a burning smell. If any defect is found, isolate the circuit and arrange inspection by a qualified electrician; terminals must never be tightened while the circuit is energised.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy