ABB

ABB Inora 2 Gang 45A Double Pole Cooker Control Unit with 13A Switched Socket and Illumination Classic Grey BL118-G

In Stock
63.74
EXCL.VAT
Incl. 5% VAT AED 66.93

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • A 45A double-pole switch controls cooker supply.
    • The 13A socket powers a nearby appliance.
    • Illumination helps locate the unit at night.
    • A 35 mm flush box supports concealed fitting.
    • Safety shutters help guard live socket contacts.
    • Classic Grey finish suits coordinated interiors.

Features & Benefits

Product Type

Cooker Control Unit with Switched Socket from the ABB Inora wiring-accessory range.

Model

BL118-G identifies the classic grey finish variant.

Configuration

2 Gang 1 Way Double Pole configuration is designed for cooker supply isolation with auxiliary socket.

Electrical Rating

45A switch and 13A socket at 250V AC supports the stated fixed-wiring application.

Indicator

Illuminated provides visible identification or easier location in low light.

Installation

Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Socket Safety

The Inora socket design uses safety shutters to help protect users from accidental access to live contacts.

Standard Compliance

BS 4177; IEC 60669-1; BS 1363-2; SASO 2203 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in Classic Grey suit cooker supply isolation with auxiliary socket in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

Classic Grey

Quantity Unit

PCS

Model No

BL118-G

Brands

ABB

Item Type

Cooker Switch

Number of Gang

2 Gang

Pole

2 Pole

Rated Current

45A

Rated Voltage

250V AC

Switch Type

Cooker Control Unit

Usage

Cooker supply isolation with auxiliary socket

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL118-G is a cooker control unit designed to provide local control for a high-load electric cooking appliance together with a convenient 13A socket outlet. It combines a 45A cooker control switch and a 13A socket in a Classic Grey finish, making it suitable for residential kitchens, villas, apartments, staff accommodation and similar UAE construction projects.

The 45A rating refers to the cooker control section, which is intended to switch an appropriately designed dedicated circuit for an electric cooker, hob or oven. The 13A rating applies to the integrated general-purpose socket outlet. These are separate functional ratings and must not be treated as a combined appliance capacity. Circuit loading, cable size and protective-device selection must be calculated by a qualified electrical professional.

The control section is commonly used for fixed electric cookers, built-in ovens, cooking ranges or electric hobs where the appliance load and circuit design fall within the unit's rating. The 13A socket may be used for a suitable plug-connected kitchen appliance within its rated capacity. Always check the appliance nameplate, manufacturer instructions and calculated demand before connection.

A fixed high-load cooking appliance will normally require a dedicated radial circuit from the distribution board. The final circuit must be designed according to the connected load, diversity assessment, installation method, ambient temperature, cable length and voltage-drop limits. The cooker control unit should not be added to a general socket circuit unless the approved electrical design specifically permits it.

Installation should be completed with the electrical supply isolated and verified dead. A compatible mounting box of suitable depth should be securely fixed, after which the line, neutral and protective-earth conductors are terminated according to ABB's wiring diagram and terminal markings. Conductors must be correctly sized, fully inserted and tightened to the specified torque. The faceplate should then be aligned and secured without trapping or damaging any cables.

No. A cooker circuit carries a substantial electrical load, so this unit should be installed, tested and commissioned by a licensed or suitably qualified electrician. Professional installation is necessary to verify conductor sizing, earthing, polarity, insulation resistance, protective-device operation and compliance with the applicable UAE authority and project requirements.

Cable size and protective-device rating cannot be selected from the switch rating alone. They depend on the cooker's actual load, circuit length, installation method, grouping, thermal insulation, ambient temperature, voltage drop and local authority requirements. The electrician or project engineer must carry out the relevant calculations and select an MCB or RCBO and cable with adequate current-carrying capacity. The protective device must safeguard the cable and must not exceed the ratings permitted by the approved circuit design.

It is suitable for consideration in UAE residential and commercial fit-out applications where a 45A cooker control unit with a 13A socket is specified. Final approval should be based on the project specifications, ABB technical documentation and the requirements of the relevant authority, such as DEWA, ADDC, SEWA or another local electricity provider. Consultants and contractors should also confirm compatibility with the approved wiring accessories, back boxes and protection system.

The installation should follow the current regulations of the relevant UAE electricity authority, the approved project specifications and applicable IEC or BS-based wiring requirements adopted for the development. Particular attention should be given to circuit protection, isolation, earthing, conductor identification, socket configuration and testing. Product certification and exact standards compliance should be confirmed from the current ABB datasheet or approval documents before consultant submission.

The unit should be readily accessible for switching and emergency isolation, while being positioned away from direct heat, steam, water splashes and the immediate area above the cooking surface. It should not be hidden behind a fixed appliance where it cannot be reached safely. The final mounting position and height should follow the kitchen layout, appliance manufacturer's instructions, accessibility requirements and approved electrical drawings.

The 13A socket is generally intended for a separate plug-connected appliance within the socket's rated load; it is not a substitute for the dedicated connection required by a high-power cooker. The cooker or hob should be connected through the correctly designed cooker circuit and appliance connection arrangement. Avoid using high-load extension leads or multiway adaptors with the integrated socket.

This type of cooker control unit is primarily intended for indoor use in a suitable dry location. It should not be exposed directly to rain, washing water, heavy condensation or outdoor dust unless installed within an enclosure that provides the required environmental and ingress protection. For outdoor kitchens or humid service areas in the UAE, the consultant should specify an appropriately IP-rated solution.

Commissioning should include verification of terminal tightness, protective-conductor continuity, insulation resistance, polarity, earth-fault protection and operation of the cooker switch and socket. The electrician should also confirm that the protective device, cable and connected appliance match the approved load calculation. Test results should be recorded as required for project handover, inspection and authority approval.

Keep the faceplate clean and dry, using a soft cloth without abrasive or solvent-based cleaners. Periodically inspect it for discoloration, cracking, looseness, unusual heat, buzzing, sparking or a burning smell. If any defect is found, stop using the circuit and arrange inspection by a qualified electrician. Internal terminals should only be accessed after safe electrical isolation.

Contractors should verify the model number BL118-G, 45A cooker-switch requirement, 13A socket configuration, Classic Grey finish, mounting-box compatibility and the project's approved ABB Inora accessory schedule. They should also confirm the latest product dimensions, terminal capacity, applicable certifications and installation instructions from ABB documentation before procurement and consultant material approval.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy