ABB

ABB Inora 2 Gang 45A Double Pole Cooker Control Unit with 13A Switched Socket and Illumination White BL118

In Stock
58.78
EXCL.VAT
Incl. 5% VAT AED 61.72

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • A 45A double-pole switch controls cooker supply.
    • The 13A socket powers a nearby appliance.
    • Illumination helps locate the unit at night.
    • A 35 mm flush box supports concealed fitting.
    • Safety shutters help guard live socket contacts.
    • White finish suits coordinated interiors.

Features & Benefits

Product Type

Cooker Control Unit with Switched Socket from the ABB Inora wiring-accessory range.

Model

BL118 identifies the white finish variant.

Configuration

2 Gang 1 Way Double Pole configuration is designed for cooker supply isolation with auxiliary socket.

Electrical Rating

45A switch and 13A socket at 250V AC supports the stated fixed-wiring application.

Indicator

Illuminated provides visible identification or easier location in low light.

Installation

Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Socket Safety

The Inora socket design uses safety shutters to help protect users from accidental access to live contacts.

Standard Compliance

BS 4177; IEC 60669-1; BS 1363-2; SASO 2203 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in White suit cooker supply isolation with auxiliary socket in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

White

Quantity Unit

PCS

Model No

BL118

Brands

ABB

Item Type

Cooker Switch

Number of Gang

2 Gang

Pole

2 Pole

Rated Current

45A

Rated Voltage

250V AC

Switch Type

Cooker Control Unit

Usage

Cooker supply isolation with auxiliary socket

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL118 is a white cooker control unit designed for residential and light-commercial kitchens. It combines a high-current 45A cooker control switch with a separate 13A socket outlet, allowing convenient local isolation of an electric cooker, oven or hob while providing a standard socket for a suitable small appliance.

The 45A rating applies to the cooker control section, while the 13A rating applies to the socket outlet. These are separate functions and must be connected according to the product terminal markings and the approved electrical design. The cooker appliance load, cable size, protective device and installation method must all be checked rather than selecting the circuit solely from the switch rating.

It may be used as a local control and isolation point for compatible electric cookers, built-in ovens and induction or ceramic hobs, provided the appliance demand and circuit design do not exceed the unit's applicable rating. High-power appliances can require dedicated circuits or different control arrangements, so the appliance nameplate and manufacturer instructions must be reviewed by a qualified electrician.

The exact internal and terminal arrangement must be verified from the BL118 markings and ABB installation instructions. A competent electrician should identify the designated supply, load, neutral and earth terminals and confirm how the socket is fed and protected. The 13A outlet must never be treated as a 45A outlet or used to connect the cooker through a standard plug unless the appliance is specifically designed for a 13A plug connection.

Installation should be completed with the supply isolated and proven dead. The electrician should use a compatible mounting box, route the cooker circuit without damaging the conductors, terminate line, neutral and protective earth according to the marked terminals, tighten connections to the manufacturer's specified torque, fit the faceplate securely and complete electrical testing before energising. The circuit must not be worked on while live.

Cable size and protective-device rating cannot be determined from the 45A switch rating alone. They depend on the cooker's connected load and diversity calculation, supply arrangement, cable length, conductor material, installation method, grouping, ambient temperature, thermal insulation and voltage-drop limits. A qualified electrical engineer or electrician should calculate the circuit and select the MCB or RCBO and cable in accordance with the applicable UAE authority requirements and project specification.

Protective earthing is essential for the control unit, socket and connected Class I cooking appliance. RCD or RCBO protection should be provided where required by the applicable wiring regulations, local authority rules and installation design, particularly for socket-outlet circuits. Earth continuity, insulation resistance, polarity and protective-device operation should be tested before the unit is put into service.

The control should be readily accessible and normally positioned so the cooker can be isolated without reaching over a hot cooking surface. It should be kept away from sinks, direct water spray, steam, excessive heat and combustible hazards. Mounting height and separation must follow the approved kitchen layout, appliance instructions, accessibility requirements and local electrical regulations.

The BL118 is relevant to UAE villas, apartments, staff accommodation and suitable commercial fit-outs where a 45A cooker control point with a 13A socket is specified. Before procurement, contractors should confirm compatibility with the project's approved material schedule, consultant requirements, appliance load and the rules of the relevant authority, such as DEWA, ADDC or the applicable local electricity provider.

Installation should comply with the current regulations of the relevant UAE electricity authority, the approved project drawings and applicable standards used by the consultant. UAE projects commonly reference requirements aligned with BS 7671 for low-voltage electrical installations and relevant BS or IEC product standards. The contractor must verify the latest authority-specific rules before installation and inspection.

This unit should not be assumed to be weatherproof because no outdoor IP rating is stated in the supplied product data. It is primarily suited to dry indoor locations. For outdoor kitchens, wash areas or locations exposed to moisture, dust or condensation, use an appropriately IP-rated enclosure or a purpose-designed weather-resistant control unit approved for the environmental conditions.

The socket may be used for an appropriate appliance only when the completed circuit design permits it and the connected load remains within the socket and circuit limits. Avoid using high-load portable appliances or extension adaptors without checking the available circuit capacity. If the cooker and socket operate simultaneously, the electrician must account for the resulting demand and protective-device coordination.

Use a mounting box that matches the BL118 faceplate format, fixing centres and required wiring depth. High-current cooker cables are relatively stiff and need sufficient space to bend without placing stress on terminals. Contractors should verify the product dimensions and ABB installation data before selecting a flush or surface box, rather than relying only on a generic accessory box.

The electrician should inspect terminal tightness and conductor identification, confirm protective-earth continuity and polarity, test insulation resistance, verify circuit and RCD or RCBO performance where applicable, and conduct functional checks of the cooker switch and 13A socket. The cooker circuit should then be labelled correctly at the distribution board and included in the project's electrical test documentation.

Isolate the electrical supply before cleaning or inspection. Wipe the faceplate with a soft, slightly damp cloth and avoid solvents, abrasive cleaners and direct water spray. Arrange inspection by a qualified electrician if the switch becomes unusually warm, produces an odour or crackling sound, feels loose, shows discoloration, or fails to operate smoothly, as these signs may indicate a loose connection, overload or component damage.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy