ABB Inora 2 Gang 45A Double Pole Cooker Control Unit with 13A Switched Socket and Illumination White BL118
FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- A 45A double-pole switch controls cooker supply.
- The 13A socket powers a nearby appliance.
- Illumination helps locate the unit at night.
- A 35 mm flush box supports concealed fitting.
- Safety shutters help guard live socket contacts.
- White finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
Cooker Control Unit with Switched Socket from the ABB Inora wiring-accessory range.
Model
BL118 identifies the white finish variant.
Configuration
2 Gang 1 Way Double Pole configuration is designed for cooker supply isolation with auxiliary socket.
Electrical Rating
45A switch and 13A socket at 250V AC supports the stated fixed-wiring application.
Indicator
Illuminated provides visible identification or easier location in low light.
Installation
Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Socket Safety
The Inora socket design uses safety shutters to help protect users from accidental access to live contacts.
Standard Compliance
BS 4177; IEC 60669-1; BS 1363-2; SASO 2203 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit cooker supply isolation with auxiliary socket in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL118
Brands
ABB
Item Type
Cooker Switch
Number of Gang
2 Gang
Pole
2 Pole
Rated Current
45A
Rated Voltage
250V AC
Switch Type
Cooker Control Unit
Usage
Cooker supply isolation with auxiliary socket
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora BL118 45A/13A cooker control unit socket?
The ABB Inora BL118 is a white cooker control unit designed for residential and light-commercial kitchens. It combines a high-current 45A cooker control switch with a separate 13A socket outlet, allowing convenient local isolation of an electric cooker, oven or hob while providing a standard socket for a suitable small appliance.
What do the 45A and 13A ratings of the ABB Inora BL118 mean?
The 45A rating applies to the cooker control section, while the 13A rating applies to the socket outlet. These are separate functions and must be connected according to the product terminal markings and the approved electrical design. The cooker appliance load, cable size, protective device and installation method must all be checked rather than selecting the circuit solely from the switch rating.
Can the ABB Inora BL118 be used for an electric cooker, oven or induction hob?
It may be used as a local control and isolation point for compatible electric cookers, built-in ovens and induction or ceramic hobs, provided the appliance demand and circuit design do not exceed the unit's applicable rating. High-power appliances can require dedicated circuits or different control arrangements, so the appliance nameplate and manufacturer instructions must be reviewed by a qualified electrician.
Is the 13A socket powered by the 45A cooker circuit?
The exact internal and terminal arrangement must be verified from the BL118 markings and ABB installation instructions. A competent electrician should identify the designated supply, load, neutral and earth terminals and confirm how the socket is fed and protected. The 13A outlet must never be treated as a 45A outlet or used to connect the cooker through a standard plug unless the appliance is specifically designed for a 13A plug connection.
How should the ABB Inora BL118 cooker control unit be installed?
Installation should be completed with the supply isolated and proven dead. The electrician should use a compatible mounting box, route the cooker circuit without damaging the conductors, terminate line, neutral and protective earth according to the marked terminals, tighten connections to the manufacturer's specified torque, fit the faceplate securely and complete electrical testing before energising. The circuit must not be worked on while live.
What cable size and circuit breaker are required for this 45A cooker control unit?
Cable size and protective-device rating cannot be determined from the 45A switch rating alone. They depend on the cooker's connected load and diversity calculation, supply arrangement, cable length, conductor material, installation method, grouping, ambient temperature, thermal insulation and voltage-drop limits. A qualified electrical engineer or electrician should calculate the circuit and select the MCB or RCBO and cable in accordance with the applicable UAE authority requirements and project specification.
Does the ABB Inora BL118 require earthing and RCD protection?
Protective earthing is essential for the control unit, socket and connected Class I cooking appliance. RCD or RCBO protection should be provided where required by the applicable wiring regulations, local authority rules and installation design, particularly for socket-outlet circuits. Earth continuity, insulation resistance, polarity and protective-device operation should be tested before the unit is put into service.
Where should a cooker control unit be positioned in a kitchen?
The control should be readily accessible and normally positioned so the cooker can be isolated without reaching over a hot cooking surface. It should be kept away from sinks, direct water spray, steam, excessive heat and combustible hazards. Mounting height and separation must follow the approved kitchen layout, appliance instructions, accessibility requirements and local electrical regulations.
Is the ABB Inora BL118 suitable for UAE residential and construction projects?
The BL118 is relevant to UAE villas, apartments, staff accommodation and suitable commercial fit-outs where a 45A cooker control point with a 13A socket is specified. Before procurement, contractors should confirm compatibility with the project's approved material schedule, consultant requirements, appliance load and the rules of the relevant authority, such as DEWA, ADDC or the applicable local electricity provider.
Which electrical standards should be considered when installing this cooker switch in the UAE?
Installation should comply with the current regulations of the relevant UAE electricity authority, the approved project drawings and applicable standards used by the consultant. UAE projects commonly reference requirements aligned with BS 7671 for low-voltage electrical installations and relevant BS or IEC product standards. The contractor must verify the latest authority-specific rules before installation and inspection.
Can the ABB Inora BL118 be installed outdoors or in a wet location?
This unit should not be assumed to be weatherproof because no outdoor IP rating is stated in the supplied product data. It is primarily suited to dry indoor locations. For outdoor kitchens, wash areas or locations exposed to moisture, dust or condensation, use an appropriately IP-rated enclosure or a purpose-designed weather-resistant control unit approved for the environmental conditions.
Can the 13A socket be used while the cooker is operating?
The socket may be used for an appropriate appliance only when the completed circuit design permits it and the connected load remains within the socket and circuit limits. Avoid using high-load portable appliances or extension adaptors without checking the available circuit capacity. If the cooker and socket operate simultaneously, the electrician must account for the resulting demand and protective-device coordination.
What mounting box is needed for the ABB Inora BL118?
Use a mounting box that matches the BL118 faceplate format, fixing centres and required wiring depth. High-current cooker cables are relatively stiff and need sufficient space to bend without placing stress on terminals. Contractors should verify the product dimensions and ABB installation data before selecting a flush or surface box, rather than relying only on a generic accessory box.
What checks should be completed after installing the ABB cooker control unit?
The electrician should inspect terminal tightness and conductor identification, confirm protective-earth continuity and polarity, test insulation resistance, verify circuit and RCD or RCBO performance where applicable, and conduct functional checks of the cooker switch and 13A socket. The cooker circuit should then be labelled correctly at the distribution board and included in the project's electrical test documentation.
How should the ABB Inora white cooker control unit be cleaned and maintained?
Isolate the electrical supply before cleaning or inspection. Wipe the faceplate with a soft, slightly damp cloth and avoid solvents, abrasive cleaners and direct water spray. Arrange inspection by a qualified electrician if the switch becomes unusually warm, produces an odour or crackling sound, feels loose, shows discoloration, or fails to operate smoothly, as these signs may indicate a loose connection, overload or component damage.
Frequently Asked Questions
The ABB Inora BL118 is a white cooker control unit designed for residential and light-commercial kitchens. It combines a high-current 45A cooker control switch with a separate 13A socket outlet, allowing convenient local isolation of an electric cooker, oven or hob while providing a standard socket for a suitable small appliance.
The 45A rating applies to the cooker control section, while the 13A rating applies to the socket outlet. These are separate functions and must be connected according to the product terminal markings and the approved electrical design. The cooker appliance load, cable size, protective device and installation method must all be checked rather than selecting the circuit solely from the switch rating.
It may be used as a local control and isolation point for compatible electric cookers, built-in ovens and induction or ceramic hobs, provided the appliance demand and circuit design do not exceed the unit's applicable rating. High-power appliances can require dedicated circuits or different control arrangements, so the appliance nameplate and manufacturer instructions must be reviewed by a qualified electrician.
The exact internal and terminal arrangement must be verified from the BL118 markings and ABB installation instructions. A competent electrician should identify the designated supply, load, neutral and earth terminals and confirm how the socket is fed and protected. The 13A outlet must never be treated as a 45A outlet or used to connect the cooker through a standard plug unless the appliance is specifically designed for a 13A plug connection.
Installation should be completed with the supply isolated and proven dead. The electrician should use a compatible mounting box, route the cooker circuit without damaging the conductors, terminate line, neutral and protective earth according to the marked terminals, tighten connections to the manufacturer's specified torque, fit the faceplate securely and complete electrical testing before energising. The circuit must not be worked on while live.
Cable size and protective-device rating cannot be determined from the 45A switch rating alone. They depend on the cooker's connected load and diversity calculation, supply arrangement, cable length, conductor material, installation method, grouping, ambient temperature, thermal insulation and voltage-drop limits. A qualified electrical engineer or electrician should calculate the circuit and select the MCB or RCBO and cable in accordance with the applicable UAE authority requirements and project specification.
Protective earthing is essential for the control unit, socket and connected Class I cooking appliance. RCD or RCBO protection should be provided where required by the applicable wiring regulations, local authority rules and installation design, particularly for socket-outlet circuits. Earth continuity, insulation resistance, polarity and protective-device operation should be tested before the unit is put into service.
The control should be readily accessible and normally positioned so the cooker can be isolated without reaching over a hot cooking surface. It should be kept away from sinks, direct water spray, steam, excessive heat and combustible hazards. Mounting height and separation must follow the approved kitchen layout, appliance instructions, accessibility requirements and local electrical regulations.
The BL118 is relevant to UAE villas, apartments, staff accommodation and suitable commercial fit-outs where a 45A cooker control point with a 13A socket is specified. Before procurement, contractors should confirm compatibility with the project's approved material schedule, consultant requirements, appliance load and the rules of the relevant authority, such as DEWA, ADDC or the applicable local electricity provider.
Installation should comply with the current regulations of the relevant UAE electricity authority, the approved project drawings and applicable standards used by the consultant. UAE projects commonly reference requirements aligned with BS 7671 for low-voltage electrical installations and relevant BS or IEC product standards. The contractor must verify the latest authority-specific rules before installation and inspection.
This unit should not be assumed to be weatherproof because no outdoor IP rating is stated in the supplied product data. It is primarily suited to dry indoor locations. For outdoor kitchens, wash areas or locations exposed to moisture, dust or condensation, use an appropriately IP-rated enclosure or a purpose-designed weather-resistant control unit approved for the environmental conditions.
The socket may be used for an appropriate appliance only when the completed circuit design permits it and the connected load remains within the socket and circuit limits. Avoid using high-load portable appliances or extension adaptors without checking the available circuit capacity. If the cooker and socket operate simultaneously, the electrician must account for the resulting demand and protective-device coordination.
Use a mounting box that matches the BL118 faceplate format, fixing centres and required wiring depth. High-current cooker cables are relatively stiff and need sufficient space to bend without placing stress on terminals. Contractors should verify the product dimensions and ABB installation data before selecting a flush or surface box, rather than relying only on a generic accessory box.
The electrician should inspect terminal tightness and conductor identification, confirm protective-earth continuity and polarity, test insulation resistance, verify circuit and RCD or RCBO performance where applicable, and conduct functional checks of the cooker switch and 13A socket. The cooker circuit should then be labelled correctly at the distribution board and included in the project's electrical test documentation.
Isolate the electrical supply before cleaning or inspection. Wipe the faceplate with a soft, slightly damp cloth and avoid solvents, abrasive cleaners and direct water spray. Arrange inspection by a qualified electrician if the switch becomes unusually warm, produces an odour or crackling sound, feels loose, shows discoloration, or fails to operate smoothly, as these signs may indicate a loose connection, overload or component damage.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy