ABB

ABB Metal Clad 1 Gang 13A Switched Fused Connection Unit with Neon BM577

In Stock
61.85
EXCL.VAT
Incl. 5% VAT AED 64.94

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • Rated at 13A for fused electrical connections.
    • Metal-clad body withstands demanding environments.
    • Neon indicator provides clear power status.
    • Single-gang design suits standard surface boxes.
    • Replaceable fuse protects connected appliances.
    • Model BM577 is designed for fixed wiring circuits.

Features & Benefits

13 A Fused Connection Unit

Provides a dedicated fused connection point for fixed electrical equipment, helping protect the connected appliance and its supply cable against overcurrent when fitted with the correctly rated fuse. The 13 A maximum rating makes it suitable for many common domestic, commercial and light-industrial applications, subject to circuit design and appliance requirements.

Integrated Neon Indicator

The built-in neon indicator provides a clear visual indication of the connection unit’s electrical status, allowing users and maintenance personnel to identify when the supply is energised more easily. This is particularly useful for fixed appliances installed away from their main operating controls.

Metal-Clad Construction

The durable metal-clad exterior is designed for locations where greater mechanical strength is preferred over standard plastic wiring accessories. It is well suited to workshops, utility rooms, garages, plant areas and commercial environments, provided the installation conditions comply with the product’s specified environmental protection rating.

1-Gang Configuration

The compact single-gang format provides one fused connection point while keeping the installation neat and space-efficient. It can be incorporated into compatible metal-clad wiring systems for a coordinated appearance and practical surface-mounted electrical installation.

Fixed-Appliance Connection

Designed to provide a controlled fused supply for equipment such as water heaters, ventilation units, pumps, kitchen appliances and other permanently connected loads. The final fuse rating, cable size and circuit protection must be selected according to the connected equipment and applicable UAE electrical installation requirements.

ABB BM577

Manufactured by ABB under model BM577, this connection unit is intended for use as part of a professional low-voltage wiring installation. Compatibility with associated mounting boxes, cable-entry accessories and other metal-clad components should be confirmed before installation.

UAE Installation Considerations

Suitable for consideration in UAE low-voltage installations operating on the standard 230 V, 50 Hz supply, subject to verification against the manufacturer’s declared voltage rating. Installation should be completed by a qualified electrician in accordance with applicable local authority regulations, including DEWA or the relevant emirate utility requirements.

Key Specifications

Custom Stock Status

In Stock

Weight

0.31 kg

Quantity Unit

PCS

Model No

BM577

Brands

ABB

Item Type

Fused Connection Unit

Number of Gang

1 Gang

Rated Current

13A

Rated Voltage

250V AC

Connector Type

Fused Connection Unit

Switch Type

Unswitched

Height

82.5 mm

Width

82.5 mm

Depth

49 mm

Usage

Protected connection of fixed appliances

Installation Type

Surface Mounted

Frequently Asked Questions

The ABB BM577 is a metal-clad, single-gang fused connection unit rated at 13A and fitted with a neon indicator. Commonly known as a fused spur or FCU, it provides local fused protection for a fixed electrical appliance or a spur connection from a suitable final circuit. Its metal construction is suited to demanding commercial, workshop, plant-room and construction-related installations where greater mechanical protection is preferred.

A 13A fused connection unit is used to connect and protect fixed electrical equipment that requires a fused supply. Typical applications may include water heaters, ventilation equipment, pumps, hand dryers, signage, control panels and other appliances, subject to the equipment load and manufacturer’s instructions. The fitted fuse must be correctly selected and must not exceed the FCU’s 13A rating.

The neon provides a visible electrical status indication. Depending on the product’s terminal arrangement and specified wiring configuration, it may indicate that power is available or that the connected load is energised. The electrician should follow the terminal markings and ABB installation information rather than assuming the indicator function from appearance alone.

The BM577 is relevant to UAE workshops, warehouses, service areas, plant rooms, commercial facilities and building maintenance projects where a robust metal-clad fused connection point is required. Product selection and installation should comply with the applicable UAE electrical regulations, project specifications and the requirements of the relevant authority, such as DEWA, ADDC or the local electricity distribution authority.

It should not be treated as weatherproof unless ABB documentation confirms an appropriate IP rating or it is installed inside a correctly rated weatherproof enclosure. For exposed UAE outdoor locations, consider dust, rain, irrigation spray, condensation, UV exposure and high ambient temperatures. The complete installation, including enclosure, glands and seals, must have a suitable environmental rating.

Installation should be completed by a qualified electrician with the circuit isolated, locked out where required and proven dead. The unit must be mounted to a compatible metal-clad box, with supply and load conductors connected to the clearly identified terminals. The protective earth conductor must be securely terminated, the metal enclosure must be earthed, cable entries should use suitable bushes or glands, and terminal screws must be tightened to the manufacturer’s specified torque. Testing is required before energising.

Because the front plate and enclosure are conductive, effective protective earthing is essential. A secure earth connection helps ensure that a fault to the metalwork causes the protective device to operate quickly, reducing electric-shock risk. Earth continuity should be verified after installation, and any required earth link between the box and accessory must be fitted in accordance with ABB instructions and local wiring regulations.

The fuse rating should be selected to protect the connected appliance and its flexible cable, and it must not exceed 13A. A lower-rated fuse may be required for equipment with a lower current demand or smaller supply lead. The appliance manufacturer’s instructions, design current, cable capacity and starting current should all be considered by the electrical designer or installer.

A fused connection unit is commonly used to supply a fused spur from an appropriate final circuit, but the connection method depends on the circuit design, conductor size, protective device and applicable wiring rules. The installer must confirm that the existing circuit has adequate capacity and fault protection. It should not be used to conceal overloading, extend an unsuitable circuit or bypass required isolation arrangements.

Only when the equipment’s normal and starting current remain within the FCU, fuse, cable and circuit ratings. A 13A supply at approximately 230V represents a theoretical maximum near 3kW, but continuous-load conditions, ambient temperature, cable derating and manufacturer requirements must be assessed. Larger heaters, air-conditioning equipment and motors may require a dedicated circuit, higher-rated isolator or contactor arrangement.

One gang means the accessory occupies a single electrical accessory position. It does not by itself confirm the exact faceplate dimensions, fixing centres or back-box depth. Before ordering for a UAE fit-out or replacement project, check compatibility with the intended ABB metal-clad mounting box, cable entries and available installation depth.

The electrician should inspect conductor terminations, polarity, fuse rating, earth continuity, insulation resistance and the security of the metal enclosure. Relevant circuit protective-device and RCD tests should also be completed where applicable. The neon indicator and connected appliance should be function-tested, and test results should be recorded as required by the project specification and local authority regulations.

It may be suitable for fixed indoor site facilities, workshops or protected service areas when incorporated into a properly designed electrical installation. Temporary construction-site supplies can involve stricter requirements for reduced voltages, RCD protection, impact resistance, dust and water ingress. The site electrical engineer should confirm suitability for the specific location and risk assessment before installation.

Verify the model number BM577, 13A rating, neon-indicator requirement, mounting-box compatibility, circuit voltage and frequency, intended fuse rating, cable size, terminal capacity and installation environment. Also confirm any required IP rating, applicable conformity documentation and project-approved brand or accessory schedule. Where specifications are critical, refer to the latest ABB technical datasheet before purchase and installation.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy