ABB

ABB Millenium 13A Fused Connection Unit with Flex and LED Silk Black AM50853-SB

In Stock
135.19
EXCL.VAT
Incl. 5% VAT AED 141.95

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • 13A rating suits the specified electrical load.
    • Switched control provides convenient local operation.
    • An LED indicator shows the operating status.
    • Flush mounting keeps fixed wiring concealed.
    • Secure terminals support dependable connections.
    • The matching frame completes the installed finish.

Features & Benefits

Local Power Control

The integrated control mechanism provides convenient switching or connection for the specified fixed electrical circuit.

Rated Current

13A is the documented current rating for the stated outlet or connection-unit configuration.

LED Status Indication

The integrated LED gives a clear visual indication of the switch or connected-circuit status.

Secure Cable Termination

The terminal arrangement supports dependable fixed-wiring connections when correctly installed.

Flush Installation

The concealed mounting arrangement keeps permanent wiring behind the finished wall surface.

Key Specifications

Custom Stock Status

In Stock

Weight

0.18 kg

Color

Silk Black

Quantity Unit

PCS

Model No

AM50853-SB

Brands

ABB

Item Type

Fused Connection Unit

Number of Gang

1 Gang

Rated Current

13A

Rated Voltage

230V AC

Connector Type

Fused Connection Unit

Dimension

42 x 86 x 86 mm

Height

86 mm

Width

86 mm

Depth

42 mm

Usage

Protected fixed appliance connection with status indication

Installation Type

Flush Mounted

Frequently Asked Questions

It may be used for a fixed water heater, dishwasher, hood, refrigerator, or similar appliance only when the normal current, starting current, manufacturer instructions, cable size, and circuit design are within the unit's 13A and 230V AC ratings. It should not be selected solely by appliance type. A qualified electrician or project engineer must verify load calculations, fuse rating, isolation requirements, and local regulations.

The key specifications include a rated current of 13A, rated voltage of 230V AC, 1-gang configuration, flush-mounted installation, integrated flex outlet, LED status indication, and approximate dimensions of 42 x 86 x 86 mm. The unit incorporates secure terminals for permanent fixed-wiring connections and is supplied in the ABB Millenium Silk Black finish.

A 13A fused connection unit, commonly called an FCU or fused spur, connects a fixed appliance to the final electrical circuit while providing local isolation or switching and replaceable fuse protection. Typical construction and fit-out applications include water heaters, kitchen appliances, ventilation equipment, pumps, display equipment, and other fixed loads, subject to the appliance rating and approved electrical design.

The flex outlet provides a controlled exit point for the flexible cable supplying the connected appliance. It helps create a neat installation without routing the appliance flex through an unsuitable gap around the faceplate. The cable must be correctly sized, securely terminated, and provided with appropriate strain management in accordance with the appliance instructions and project electrical requirements.

The integrated LED offers a clear visual indication of the unit's operating or connected-circuit status. This is useful where users or maintenance teams need to identify whether power has been selected for a fixed appliance. The precise indication can depend on how the unit is wired, so the installer should follow the ABB wiring diagram supplied with the product.

Its 13A and 230V AC ratings are compatible with many low-voltage fixed-appliance applications found in the UAE. Suitability must still be confirmed against the approved project specification, connected load, circuit protection, local authority requirements, and relevant wiring regulations. Installation should be completed by a qualified electrician in accordance with applicable UAE regulations and the requirements of authorities such as DEWA, ADDC, SEWA, or the relevant local utility.

Isolate and verify the electrical supply before installation. Mount the unit in a compatible concealed wall box, prepare conductors without damaging them, and connect live, neutral, and earth conductors to the marked terminals according to the ABB wiring diagram. Fit the correctly rated fuse, route and terminate the appliance flex through the outlet, secure all terminal screws to the specified torque, attach the matching frame and faceplate, and then complete continuity, polarity, insulation-resistance, earthing, and functional tests before energising the circuit.

The AM50853-SB requires a compatible concealed mounting box and adequate internal depth for the device, conductors, terminations, and cable bend radius. The product dimensions are approximately 42 x 86 x 86 mm, but installers should verify the ABB mounting requirements and the selected Millenium frame before preparing blockwork, drywall, joinery, or wall finishes. The box should be level, firmly fixed, and positioned so the finished faceplate sits correctly against the wall.

A continuous and correctly terminated protective earth is essential for fault protection, particularly when the connected appliance has exposed conductive parts. The electrician should confirm earth continuity, correct conductor identification, secure termination, and required test results before commissioning. The earth conductor must not be omitted, cut back, or used for any other purpose.

Verify the model number AM50853-SB, 13A current rating, 230V AC supply, Silk Black finish, 1-gang format, flush-mounting requirement, flex-outlet configuration, LED function, matching ABB Millenium frame, and compatibility with the chosen back box. The project engineer should also confirm that the unit matches the electrical specification, appliance load, interior finish schedule, and applicable UAE authority requirements.

Keep the faceplate clean with a soft, dry or lightly damp cloth and avoid abrasive cleaners or solvents that could damage the Silk Black finish. If the LED is off or the appliance has no power, isolate the circuit and have a qualified electrician check the upstream supply, switch operation, fuse, terminals, flex, and appliance. Repeated fuse failure indicates an electrical fault or overload and must not be addressed by installing a higher-rated fuse.

Contractors should confirm the appliance location, mounting height, cable route, concealed box depth, wall finish, frame compatibility, and access for future fuse replacement before first-fix work. During second fix, the unit should be installed only after dusty or wet trades are complete, protected from paint and debris, and aligned with adjacent ABB Millenium accessories. Final circuit schedules and as-built drawings should identify the load controlled by the fused connection unit.

The fuse must protect the connected appliance and flexible cable and must never exceed the FCU's 13A rating. A lower-rated fuse may be required when specified by the appliance manufacturer or when needed to protect a smaller load or flex. Fuse selection should be based on operating current, inrush characteristics, cable capacity, and the manufacturer's instructions, using an approved fuse of the correct type and dimensions.

A fused connection unit can commonly supply a fixed load from a suitably designed ring or radial final circuit, with the fuse providing downstream protection appropriate to the appliance flex and load. The connection method, conductor size, protective device, fault-loop conditions, and permissible circuit loading must be checked against the approved electrical design and applicable wiring regulations.

The ABB Millenium AM50853-SB is a flush-mounted, 1-gang fused connection unit designed to provide local control and fused protection for a fixed electrical appliance or load. It is rated at 13A and 230V AC, includes a flex outlet for the appliance cable, and features an LED indicator that provides a visible indication of operating or connected-circuit status. Its Silk Black finish is suited to contemporary residential, commercial, hospitality, and fit-out interiors.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy