ABB

ABB Millenium 13A Fused Connection Unit with Flex White Glass AM50653-WG

In Stock
176.28
EXCL.VAT
Incl. 5% VAT AED 185.09

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • 13A rating suits the specified electrical load.
    • Switched control provides convenient local operation.
    • Flush mounting keeps fixed wiring concealed.
    • Secure terminals support dependable connections.
    • The matching frame completes the installed finish.

Features & Benefits

Local Power Control

The integrated control mechanism provides convenient switching or connection for the specified fixed electrical circuit.

Rated Current

13A is the documented current rating for the stated outlet or connection-unit configuration.

Secure Cable Termination

The terminal arrangement supports dependable fixed-wiring connections when correctly installed.

Flush Installation

The concealed mounting arrangement keeps permanent wiring behind the finished wall surface.

Millenium System Coordination

The mechanism and decorative finish coordinate with compatible ABB Millenium frames and accessories.

Key Specifications

Custom Stock Status

In Stock

Weight

0.08 kg

Color

White Glass

Quantity Unit

PCS

Model No

AM50653-WG

Brands

ABB

Item Type

Fused Connection Unit

Number of Gang

1 Gang

Rated Current

13A

Rated Voltage

230V AC

Connector Type

Fused Connection Unit

Dimension

42 x 86 x 86 mm

Height

86 mm

Width

86 mm

Depth

42 mm

Usage

Protected fixed appliance connection

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Millenium AM50653-WG is a 1-gang, flush-mounted fused connection unit designed to provide local control and fused protection for a fixed electrical appliance or load. It has a 13A rated current, operates at 230V AC, includes a flex outlet for the appliance cable, and features a white glass finish that coordinates with compatible ABB Millenium frames and accessories.

Routine maintenance is limited but should include checking for overheating, discoloration, cracked glass, loose mounting, damaged flex, unusual noise, or repeated fuse operation. Isolate the circuit before inspection or fuse replacement. A fuse that repeatedly fails indicates a possible appliance, cable, or circuit fault and should be investigated rather than replaced with a higher rating.

After installation, a qualified electrician should inspect terminal tightness, conductor identification, earthing, polarity, insulation resistance, protective-device coordination, switching operation, and the suitability of the fitted fuse. Functional testing should then confirm that the connected appliance operates correctly and that the installation meets the project's testing and handover requirements.

The listed product dimensions are approximately 42 x 86 x 86 mm. The installer should verify the compatible flush box, usable internal depth, terminal clearance, cable bending radius, and ABB Millenium frame requirements before ordering or cutting the wall. Adequate space is important to avoid cable damage and pressure on the terminals.

Not as a direct functional substitute in every application. A fused connection unit is intended primarily for a fixed or semi-fixed appliance connection through its flex outlet, whereas a socket outlet is intended for a removable plug. Any conversion must be assessed for circuit configuration, load, accessibility, isolation, cable protection, and compliance with the approved electrical design.

Yes. Its white glass finish and concealed flush-mounting format suit villas, apartments, hotels, offices, retail spaces, and other projects where electrical accessories must coordinate with modern interior finishes. For a consistent appearance, use compatible ABB Millenium frames and accessories from the same coordinated range.

It may be used in suitable dry indoor locations, including kitchens, when installed in accordance with the circuit design and appliance requirements. For bathrooms, wet areas, outdoor locations, or dusty construction environments, confirm the required ingress protection, installation zone, enclosure, and local authority rules. No specific IP rating is stated in the supplied product data, so it should not be assumed to be weatherproof or splashproof.

The fuse rating should be selected to protect the connected appliance and its flexible cable and must never exceed the FCU's 13A rating. A lower-rated fuse may be required depending on the equipment manufacturer's instructions and cable capacity. Use only a compatible approved fuse type, and have fuse selection confirmed by a qualified electrician.

Before installation, confirm the approved electrical drawings, load schedule, circuit rating, conductor size, earthing continuity, back-box dimensions, mounting depth, appliance instructions, and compatibility with the selected ABB Millenium frame. Contractors should also check coordination with wall finishes, tiles, joinery, and MEP access requirements before final fixing.

The unit is designed for flush mounting in a compatible wall box so that the permanent wiring remains concealed. Installation generally involves isolating and verifying the circuit as dead, preparing the back box, connecting the supply and load conductors to the identified terminals, fitting the correctly rated fuse, securing the flex with appropriate cable management, and attaching the compatible ABB Millenium frame. Installation should only be completed and tested by a qualified electrician.

Yes, the integrated switched control provides convenient local operation for the connected load. However, the installer must confirm whether the switching arrangement provides the type of isolation required by the appliance manufacturer, project specification, and applicable electrical regulations. The upstream circuit must still be safely isolated before maintenance.

The documented rated current is 13A, but suitability depends on the actual appliance load, cable type, ambient conditions, circuit protection, and installation method. The connected equipment must not exceed the unit or fuse rating. Continuous or high-load equipment should be checked by a qualified electrical engineer or electrician before installation.

Yes, its 230V AC rating is suitable for the nominal low-voltage supply commonly used in UAE buildings. The complete circuit, cable size, protective device, earthing arrangement, and installation method must comply with the applicable UAE authority requirements, approved project specifications, and relevant electrical installation standards.

A 13A fused connection unit, commonly called an FCU or fused spur, is used to connect and locally isolate compatible fixed appliances while providing fuse protection to the outgoing flexible cable. Typical applications may include ventilation equipment, small water heaters, kitchen appliances, pumps, signage, and other fixed loads, subject to the appliance rating, circuit design, and manufacturer instructions.

This fused connection unit is rated at 13A and 230V AC. It uses a flush-mounted installation format, has a 1-gang configuration, and measures approximately 42 x 86 x 86 mm. Secure terminals support fixed-wiring connections, while the integrated flex outlet allows a suitable appliance cable to exit neatly from the unit.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy