FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- 13A rating suits the specified electrical load.
- Double-pole switching isolates live and neutral.
- An LED indicator shows the operating status.
- Flush mounting keeps fixed wiring concealed.
- Secure terminals support dependable connections.
- The matching frame completes the installed finish.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Local Power Control
The integrated control mechanism provides convenient switching or connection for the specified fixed electrical circuit.
Rated Current
13A is the documented current rating for the stated outlet or connection-unit configuration.
Double-Pole Isolation
Both live and neutral conductors are switched together to provide more complete isolation for compatible loads.
LED Status Indication
The integrated LED gives a clear visual indication of the switch or connected-circuit status.
Secure Cable Termination
The terminal arrangement supports dependable fixed-wiring connections when correctly installed.
Flush Installation
The concealed mounting arrangement keeps permanent wiring behind the finished wall surface.
Key Specifications
Custom Stock Status
In Stock
Weight
0.20 kg
Color
Matt Gold
Quantity Unit
PCS
Model No
AM23886-MG
Brands
ABB
Item Type
Switched Socket
Number of Gang
1 Gang
Pole
2 Pole
Rated Current
13A
Rated Voltage
250V AC
Connector Type
BS 13A Socket Outlet
Dimension
35 x 86 x 86 mm
Switch Type
Switched Socket
Height
86 mm
Width
86 mm
Depth
35 mm
Usage
General-purpose appliance connection with status indication
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Millenium AM23886-MG 13A switched socket?
The ABB Millenium AM23886-MG is a one-gang BS 13A socket outlet with double-pole switching, an integrated LED status indicator and a matt gold finish. It is rated at 13A and 250V AC and is designed for flush-mounted fixed-wiring installations in homes, offices, hotels and other suitable UAE building interiors.
What does double-pole switching mean on this ABB 13A socket?
Double-pole switching means that the switch disconnects both the live and neutral conductors at the same time. This provides more complete local isolation than a single-pole socket, subject to correct wiring and circuit design. The protective earth connection remains continuous and must not be switched.
Is the ABB Millenium AM23886-MG suitable for UAE electrical systems?
The socket is rated at 250V AC and uses a BS 13A socket configuration, making it relevant to the 230V, 50Hz supply and British-style 13A plugs commonly used in the UAE. Final selection and installation must comply with the applicable UAE electrical regulations, project specifications and requirements of the relevant local authority.
Is this a single or double socket outlet?
This model is a one-gang socket outlet intended for one BS 13A plug. The term double pole describes the switching of both live and neutral; it does not mean that the product has two plug outlets.
What is the purpose of the LED indicator?
The integrated LED provides a convenient visual indication of the socket or switch status. This is useful in bedrooms, kitchens, offices, hotel rooms and facilities-management applications where users need to identify whether the outlet is switched on. The exact indication depends on the manufacturer's terminal configuration and correct installation.
Which appliances can be connected to this 13A switched socket?
It can supply compatible appliances fitted with a BS-style fused 13A plug, provided the connected load does not exceed the socket rating or the capacity of the circuit. Typical applications include televisions, computers, lamps and small household or office appliances. High-load equipment must be checked against its nameplate current, starting current and manufacturer instructions before connection.
Can the ABB AM23886-MG be used for air conditioners, water heaters or other fixed loads?
Do not select the socket solely because it carries a 13A rating. Air conditioners, water heaters, pumps and similar construction-services equipment may require a dedicated circuit, suitable protective device, local isolator or fused connection unit. A qualified electrical engineer or electrician should confirm the equipment load, cable size, starting current and UAE project requirements.
How is the ABB Millenium 13A socket installed?
The unit is designed for flush mounting with concealed fixed wiring. Installation generally involves isolating and proving the circuit dead, confirming the mounting box and cable arrangement, terminating live, neutral and earth conductors at the marked terminals, securing the mechanism without trapping cables, fitting the matching frame and completing electrical tests before energising. Installation should only be performed by a qualified electrician.
What mounting box and wall preparation are required?
The listed product dimensions are approximately 35 x 86 x 86 mm. Before wall finishing, the contractor should verify that the selected concealed box, screw centres, internal depth and cable-entry positions are compatible with the ABB Millenium mechanism and frame. Additional space may be needed for safe conductor bending and termination, particularly with larger cables or multiple conductors.
What electrical tests should be completed after installation?
The electrician should perform the tests required by the applicable installation rules and project specifications. These may include protective-conductor continuity, polarity, insulation resistance, earth-fault loop or protective-device verification, RCD operation where applicable, terminal security and functional checks of the double-pole switch and LED indicator.
Is this matt gold socket suitable for bathrooms or outdoor areas?
No weatherproof or ingress-protection rating is stated in the supplied product data, so it should be treated as an indoor flush-mounted accessory for dry locations unless ABB documentation confirms otherwise. Bathrooms, balconies, gardens, wash areas and other damp or exposed locations require correctly rated accessories, suitable zoning and appropriate RCD protection under applicable UAE requirements.
Where is the matt gold finish commonly specified in UAE construction projects?
The matt gold finish is suited to premium villas, apartments, hotels, executive offices, retail interiors and hospitality fit-outs where electrical accessories must coordinate with warm metallic hardware, lighting trims or interior finishes. Contractors should confirm the approved finish sample and matching ABB Millenium frame before bulk procurement.
Does the socket include a matching frame?
The product information states that a matching frame completes the installed finish. Contractors should nevertheless verify the exact package contents and frame compatibility before ordering, especially for project quantities, because mechanisms, frames and mounting accessories may be supplied or scheduled separately depending on the configuration.
How should this ABB Millenium switched socket be maintained?
Keep the faceplate dry and clean it with a soft cloth; avoid abrasive products, solvents and excessive moisture that could damage the matt gold finish. Periodically inspect for heat discolouration, looseness, cracking, unusual LED behaviour or plug damage. If any defect is found, isolate the circuit and have the socket checked by a qualified electrician rather than opening it while energised.
Frequently Asked Questions
The ABB Millenium AM23886-MG is a one-gang BS 13A socket outlet with double-pole switching, an integrated LED status indicator and a matt gold finish. It is rated at 13A and 250V AC and is designed for flush-mounted fixed-wiring installations in homes, offices, hotels and other suitable UAE building interiors.
Double-pole switching means that the switch disconnects both the live and neutral conductors at the same time. This provides more complete local isolation than a single-pole socket, subject to correct wiring and circuit design. The protective earth connection remains continuous and must not be switched.
The socket is rated at 250V AC and uses a BS 13A socket configuration, making it relevant to the 230V, 50Hz supply and British-style 13A plugs commonly used in the UAE. Final selection and installation must comply with the applicable UAE electrical regulations, project specifications and requirements of the relevant local authority.
This model is a one-gang socket outlet intended for one BS 13A plug. The term double pole describes the switching of both live and neutral; it does not mean that the product has two plug outlets.
The integrated LED provides a convenient visual indication of the socket or switch status. This is useful in bedrooms, kitchens, offices, hotel rooms and facilities-management applications where users need to identify whether the outlet is switched on. The exact indication depends on the manufacturer's terminal configuration and correct installation.
It can supply compatible appliances fitted with a BS-style fused 13A plug, provided the connected load does not exceed the socket rating or the capacity of the circuit. Typical applications include televisions, computers, lamps and small household or office appliances. High-load equipment must be checked against its nameplate current, starting current and manufacturer instructions before connection.
Do not select the socket solely because it carries a 13A rating. Air conditioners, water heaters, pumps and similar construction-services equipment may require a dedicated circuit, suitable protective device, local isolator or fused connection unit. A qualified electrical engineer or electrician should confirm the equipment load, cable size, starting current and UAE project requirements.
The unit is designed for flush mounting with concealed fixed wiring. Installation generally involves isolating and proving the circuit dead, confirming the mounting box and cable arrangement, terminating live, neutral and earth conductors at the marked terminals, securing the mechanism without trapping cables, fitting the matching frame and completing electrical tests before energising. Installation should only be performed by a qualified electrician.
The listed product dimensions are approximately 35 x 86 x 86 mm. Before wall finishing, the contractor should verify that the selected concealed box, screw centres, internal depth and cable-entry positions are compatible with the ABB Millenium mechanism and frame. Additional space may be needed for safe conductor bending and termination, particularly with larger cables or multiple conductors.
The electrician should perform the tests required by the applicable installation rules and project specifications. These may include protective-conductor continuity, polarity, insulation resistance, earth-fault loop or protective-device verification, RCD operation where applicable, terminal security and functional checks of the double-pole switch and LED indicator.
No weatherproof or ingress-protection rating is stated in the supplied product data, so it should be treated as an indoor flush-mounted accessory for dry locations unless ABB documentation confirms otherwise. Bathrooms, balconies, gardens, wash areas and other damp or exposed locations require correctly rated accessories, suitable zoning and appropriate RCD protection under applicable UAE requirements.
The matt gold finish is suited to premium villas, apartments, hotels, executive offices, retail interiors and hospitality fit-outs where electrical accessories must coordinate with warm metallic hardware, lighting trims or interior finishes. Contractors should confirm the approved finish sample and matching ABB Millenium frame before bulk procurement.
The product information states that a matching frame completes the installed finish. Contractors should nevertheless verify the exact package contents and frame compatibility before ordering, especially for project quantities, because mechanisms, frames and mounting accessories may be supplied or scheduled separately depending on the configuration.
Keep the faceplate dry and clean it with a soft cloth; avoid abrasive products, solvents and excessive moisture that could damage the matt gold finish. Periodically inspect for heat discolouration, looseness, cracking, unusual LED behaviour or plug damage. If any defect is found, isolate the circuit and have the socket checked by a qualified electrician rather than opening it while energised.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy