ABB

ABB Millenium 13A Single Pole Switched Socket Black Glass AM23386-BG

In Stock
176.28
EXCL.VAT
Incl. 5% VAT AED 185.09

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • 13A rating suits the specified electrical load.
    • Single-pole switching controls the live conductor.
    • Flush mounting keeps fixed wiring concealed.
    • Secure terminals support dependable connections.
    • The matching frame completes the installed finish.

Features & Benefits

Local Power Control

The integrated control mechanism provides convenient switching or connection for the specified fixed electrical circuit.

Rated Current

13A is the documented current rating for the stated outlet or connection-unit configuration.

Single-Pole Switching

The live conductor is switched to provide local control of the compatible connected load.

Secure Cable Termination

The terminal arrangement supports dependable fixed-wiring connections when correctly installed.

Flush Installation

The concealed mounting arrangement keeps permanent wiring behind the finished wall surface.

Key Specifications

Custom Stock Status

In Stock

Weight

0.08 kg

Color

Black Glass

Quantity Unit

PCS

Model No

AM23386-BG

Brands

ABB

Item Type

Single Socket

Number of Gang

1 Gang

Pole

1 Pole

Rated Current

13A

Rated Voltage

250V AC

Connector Type

BS 13A Socket Outlet

Dimension

35 x 86 x 86 mm

Switch Type

Switched Socket

Height

86 mm

Width

86 mm

Depth

35 mm

Usage

General-purpose appliance connection

Installation Type

Flush Mounted

Frequently Asked Questions

This product should be treated as an indoor flush-mounted wiring accessory unless the project documentation confirms a suitable environmental or ingress-protection rating. In kitchens, bathrooms, outdoor spaces or other damp locations, socket positioning and protection must comply with the applicable electrical zones and local regulations. Use an appropriately rated weatherproof or moisture-resistant outlet where exposure is expected.

Before handover, a qualified electrician should complete the tests required by the project and local electrical rules. These generally include protective-conductor continuity, insulation resistance, polarity, earth-fault protection and functional switching checks. The socket should also be inspected for secure mounting, correct frame alignment and signs of damaged terminals or conductors.

The socket combines a contemporary black glass finish with concealed flush mounting and local switched control. This makes it relevant to modern UAE villas, hospitality spaces, executive offices and upscale fit-outs where electrical accessories must coordinate with dark joinery, stone surfaces, feature walls and other premium finishes.

It may replace an existing compatible 1-gang flush socket if the circuit rating, wiring condition, conductor arrangement, back-box dimensions and mounting points are suitable. Because the product has an 86 x 86 mm face and approximately 35 mm depth, the electrician should inspect the existing box and confirm adequate space before replacement.

Terminals must be tightened securely to the manufacturer's specified torque where provided. Undertightening can cause loose connections, overheating and unreliable operation, while overtightening may damage the conductor or terminal assembly. Conductors should be correctly stripped, fully inserted and checked before the faceplate is fitted.

Switch off or isolate the circuit before cleaning. Wipe the glass surface gently with a soft, dry or slightly damp microfiber cloth, then dry it to prevent streaks. Do not spray liquid directly onto the socket or use abrasive pads, blades, solvents or aggressive chemicals, as these may damage the glass finish or allow moisture to reach the electrical mechanism.

RCD or RCBO protection may be required depending on the circuit, installation location, local authority regulations and project design. The ABB socket itself does not replace protective devices at the distribution board. The electrical consultant or licensed contractor should select the required residual-current and overcurrent protection for the installation.

A 13A socket may be used on a correctly designed ring or radial final circuit where permitted by the applicable wiring rules and project specification. Circuit topology, conductor size, protective device rating, fault protection and the number of outlets must be assessed by the electrical designer or licensed electrician rather than determined from the socket rating alone.

Yes. The protective earth conductor must be correctly terminated in accordance with the terminal markings and the building's earthing arrangement. Earth continuity, polarity and circuit protection should be verified during commissioning by a qualified electrician before the socket is put into service.

The ABB Millenium AM23386-BG is a 1-gang, flush-mounted BS 13A socket outlet with an integrated single-pole switch and a premium black glass finish. Rated at 13A and 250V AC, it provides local control of a compatible connected appliance while keeping the fixed wiring concealed behind the finished wall.

Contractors should confirm the 13A load requirement, 250V AC circuit, single-pole switching arrangement, BS 13A plug compatibility, 1-gang layout, 86 x 86 mm face dimensions, back-box depth, earthing provision and coordination with ABB Millenium frames and adjacent accessories. Samples and approved finishes should also be checked against architectural schedules before procurement.

Use a compatible 1-gang concealed back box that accommodates the socket mechanism, cable bend radius and approximately 35 mm product depth. The required box depth can vary with cable size, terminal space and wall construction, so the electrician should verify compatibility before blockwork chasing, drywall closure or final finishing.

The socket is designed for flush mounting into a compatible concealed wall box. A qualified electrician should isolate and verify the circuit as dead, confirm the back-box depth and cable condition, terminate the live, neutral and earth conductors at the marked terminals, secure the mechanism without overtightening, fit the matching frame and glass finish, and then complete continuity, polarity, insulation and functional tests before energising the circuit.

Yes. Its premium black glass appearance is suitable for contemporary villas, apartments, offices, hotels, reception areas, meeting rooms and high-end interior fit-out projects. The 86 x 86 mm format and concealed installation help create a neat wall finish, subject to compatibility with the selected back box, frame and surrounding wiring accessories.

It can supply compatible appliances fitted with a BS-type 13A plug, provided the connected load remains within the socket rating and the circuit design. Typical uses include televisions, computers, lamps, chargers and suitable household or office equipment. High-load appliances should only be connected after confirming their current demand, plug fuse, cable size and circuit protection.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy