- 13A rating suits the specified electrical load.
- Switched control provides convenient local operation.
- An LED indicator shows the operating status.
- Flush mounting keeps fixed wiring concealed.
- Secure terminals support dependable connections.
- The matching frame completes the installed finish.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Local Power Control
The integrated control mechanism provides convenient switching or connection for the specified fixed electrical circuit.
Rated Current
13A is the documented current rating for the stated outlet or connection-unit configuration.
LED Status Indication
The integrated LED gives a clear visual indication of the switch or connected-circuit status.
Secure Cable Termination
The terminal arrangement supports dependable fixed-wiring connections when correctly installed.
Flush Installation
The concealed mounting arrangement keeps permanent wiring behind the finished wall surface.
Key Specifications
Custom Stock Status
In Stock
Weight
0.18 kg
Color
Antique Gold
Quantity Unit
PCS
Model No
AM50753-AG
Brands
ABB
Item Type
Fused Connection Unit
Number of Gang
1 Gang
Rated Current
13A
Rated Voltage
230V AC
Connector Type
Fused Connection Unit
Dimension
42 x 86 x 86 mm
Switch Type
Switched Fused Connection Unit
Height
86 mm
Width
86 mm
Depth
42 mm
Usage
Controlled and protected fixed appliance connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Millenium AM50753-AG 13A switched fused connection unit?
The ABB Millenium AM50753-AG is a 1-gang, flush-mounted fused connection unit designed to provide local switching and fused protection for a fixed electrical appliance or load. It is rated at 13A and 230V AC and includes a flex outlet, an LED status indicator and an Antique Gold finish. Its overall dimensions are approximately 42 x 86 x 86 mm.
Why choose the ABB Millenium AM50753-AG for UAE residential or commercial projects?
This model combines a 13A, 230V AC fused connection point with local switching, an appliance flex outlet, LED status indication and a coordinated Antique Gold finish. Its flush-mounted format supports concealed wiring and a neat architectural appearance, making it relevant to villas, apartments, hospitality interiors and selected commercial fit-outs where the electrical schedule calls for a 13A FCU.
How should the Antique Gold finish be protected during construction?
Keep the visible plate and frame covered until dusty work, painting and wet trades are complete. Avoid abrasive pads, solvents, cement residue and harsh chemical cleaners, as these may damage the decorative surface. For routine cleaning, isolate the supply and use a soft, dry or lightly damp cloth without allowing moisture to enter the unit.
Does this ABB fused connection unit provide circuit isolation?
The switch provides convenient local control of the connected load, but the installer must confirm its pole configuration and isolation capability against the appliance and project requirements. Where full double-pole isolation is required, a separately specified double-pole isolator may be necessary. Always isolate the upstream circuit and verify that it is dead before carrying out work.
Is the ABB Millenium Antique Gold fused connection unit suitable for kitchens, bathrooms or outdoor areas?
Use in kitchens or other indoor locations depends on the installation zone, environmental conditions and project requirements. Do not assume that the decorative faceplate provides water or dust protection, as no IP rating is stated in the supplied product data. Bathrooms, wet areas and outdoor installations may require a suitably IP-rated accessory, additional protection and compliance with location-specific electrical rules.
Can the ABB 13A switched fused spur be used for an air conditioner or water heater?
It may be suitable only where the appliance's rated current, starting characteristics and manufacturer instructions permit connection through a 13A fused connection unit. Many air conditioners and higher-power water heaters require a dedicated circuit, higher-rated isolator or double-pole switching arrangement. The MEP design and local authority requirements must therefore be checked before selection.
What electrical tests should be carried out after installation?
A qualified electrician should perform the tests required by the approved project specification and applicable UAE regulations. These normally include protective-conductor continuity, insulation resistance, polarity, earth-fault loop or protective-device verification where applicable, functional switching and confirmation of the LED indication. Test results should be recorded as part of commissioning and handover documentation.
Can this fused connection unit be installed in concrete, blockwork or drywall partitions?
Yes, it may be incorporated into common UAE construction wall systems when a suitable flush box and approved wiring method are used. For concrete or blockwork, the box and conduit positions should be coordinated before plastering or finishing. For drywall, a compatible cavity box and secure support are required. The finished box should be level, correctly recessed and free from plaster or debris.
What back box and wall preparation are required for installation?
The product is a 1-gang unit with an approximately 86 x 86 mm face size and a stated overall depth of about 42 mm. Before wall finishing, the contractor should confirm the compatible box type, fixing centres and minimum internal depth using the ABB installation information. Additional space may be needed for conductor bending, terminations and the outgoing flex, especially where larger cables are specified.
How is the ABB AM50753-AG installed?
This model is intended for flush mounting, with the wiring and mounting box concealed behind the finished wall surface. The electrician should isolate the supply, confirm the back-box compatibility and available depth, route the fixed cable and appliance flex correctly, terminate line, neutral and earth conductors at the identified terminals, secure the flex without damaging it, fit the unit and frame, and then complete the required electrical tests before energising.
What is the purpose of the LED indicator on the ABB Millenium fused spur?
The integrated LED provides a visible indication of the switch or connected-circuit status, helping users identify whether local power is enabled. It should not be treated as proof that the circuit is electrically safe or fully isolated; an approved voltage tester and proper safe-isolation procedure must be used before maintenance.
How should the fuse rating be selected for the connected appliance?
The fuse should be selected according to the appliance manufacturer's instructions, operating current, flex size and circuit design. The chosen fuse must not exceed the 13A rating of the connection unit. Using an oversized fuse can reduce protection for the appliance flex, while an undersized fuse may operate unnecessarily during normal use.
What does the 13A rating of this ABB fused connection unit mean?
The 13A rating is the maximum documented current rating of the connection-unit configuration. The connected appliance must not exceed this rating, and the circuit conductors, protective device and fuse must be selected to suit the actual design load. A 13A rating does not mean that every appliance should automatically use a 13A fuse.
Is the ABB AM50753-AG suitable for electrical installations in the UAE?
Its 230V AC rating is compatible with the nominal low-voltage supply commonly used in UAE buildings. Suitability must still be verified against the project's load schedule, wiring specifications and the requirements of the relevant local authority, such as DEWA, ADDC or the applicable emirate-level utility. Installation should be completed and tested by a qualified electrician.
What is a switched fused connection unit with a flex outlet used for?
A switched fused connection unit, commonly called an FCU or fused spur, connects a fixed appliance to the building's electrical circuit while providing local isolation and fuse protection. The flex outlet allows the appliance cable to exit neatly from the unit. Typical applications can include water heaters, extractor fans, kitchen equipment and other permanently connected loads, subject to the appliance rating and approved electrical design.
Frequently Asked Questions
The ABB Millenium AM50753-AG is a 1-gang, flush-mounted fused connection unit designed to provide local switching and fused protection for a fixed electrical appliance or load. It is rated at 13A and 230V AC and includes a flex outlet, an LED status indicator and an Antique Gold finish. Its overall dimensions are approximately 42 x 86 x 86 mm.
This model combines a 13A, 230V AC fused connection point with local switching, an appliance flex outlet, LED status indication and a coordinated Antique Gold finish. Its flush-mounted format supports concealed wiring and a neat architectural appearance, making it relevant to villas, apartments, hospitality interiors and selected commercial fit-outs where the electrical schedule calls for a 13A FCU.
Keep the visible plate and frame covered until dusty work, painting and wet trades are complete. Avoid abrasive pads, solvents, cement residue and harsh chemical cleaners, as these may damage the decorative surface. For routine cleaning, isolate the supply and use a soft, dry or lightly damp cloth without allowing moisture to enter the unit.
The switch provides convenient local control of the connected load, but the installer must confirm its pole configuration and isolation capability against the appliance and project requirements. Where full double-pole isolation is required, a separately specified double-pole isolator may be necessary. Always isolate the upstream circuit and verify that it is dead before carrying out work.
Use in kitchens or other indoor locations depends on the installation zone, environmental conditions and project requirements. Do not assume that the decorative faceplate provides water or dust protection, as no IP rating is stated in the supplied product data. Bathrooms, wet areas and outdoor installations may require a suitably IP-rated accessory, additional protection and compliance with location-specific electrical rules.
It may be suitable only where the appliance's rated current, starting characteristics and manufacturer instructions permit connection through a 13A fused connection unit. Many air conditioners and higher-power water heaters require a dedicated circuit, higher-rated isolator or double-pole switching arrangement. The MEP design and local authority requirements must therefore be checked before selection.
A qualified electrician should perform the tests required by the approved project specification and applicable UAE regulations. These normally include protective-conductor continuity, insulation resistance, polarity, earth-fault loop or protective-device verification where applicable, functional switching and confirmation of the LED indication. Test results should be recorded as part of commissioning and handover documentation.
Yes, it may be incorporated into common UAE construction wall systems when a suitable flush box and approved wiring method are used. For concrete or blockwork, the box and conduit positions should be coordinated before plastering or finishing. For drywall, a compatible cavity box and secure support are required. The finished box should be level, correctly recessed and free from plaster or debris.
The product is a 1-gang unit with an approximately 86 x 86 mm face size and a stated overall depth of about 42 mm. Before wall finishing, the contractor should confirm the compatible box type, fixing centres and minimum internal depth using the ABB installation information. Additional space may be needed for conductor bending, terminations and the outgoing flex, especially where larger cables are specified.
This model is intended for flush mounting, with the wiring and mounting box concealed behind the finished wall surface. The electrician should isolate the supply, confirm the back-box compatibility and available depth, route the fixed cable and appliance flex correctly, terminate line, neutral and earth conductors at the identified terminals, secure the flex without damaging it, fit the unit and frame, and then complete the required electrical tests before energising.
The integrated LED provides a visible indication of the switch or connected-circuit status, helping users identify whether local power is enabled. It should not be treated as proof that the circuit is electrically safe or fully isolated; an approved voltage tester and proper safe-isolation procedure must be used before maintenance.
The fuse should be selected according to the appliance manufacturer's instructions, operating current, flex size and circuit design. The chosen fuse must not exceed the 13A rating of the connection unit. Using an oversized fuse can reduce protection for the appliance flex, while an undersized fuse may operate unnecessarily during normal use.
The 13A rating is the maximum documented current rating of the connection-unit configuration. The connected appliance must not exceed this rating, and the circuit conductors, protective device and fuse must be selected to suit the actual design load. A 13A rating does not mean that every appliance should automatically use a 13A fuse.
Its 230V AC rating is compatible with the nominal low-voltage supply commonly used in UAE buildings. Suitability must still be verified against the project's load schedule, wiring specifications and the requirements of the relevant local authority, such as DEWA, ADDC or the applicable emirate-level utility. Installation should be completed and tested by a qualified electrician.
A switched fused connection unit, commonly called an FCU or fused spur, connects a fixed appliance to the building's electrical circuit while providing local isolation and fuse protection. The flex outlet allows the appliance cable to exit neatly from the unit. Typical applications can include water heaters, extractor fans, kitchen equipment and other permanently connected loads, subject to the appliance rating and approved electrical design.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy