- 45A rating suits the specified electrical load.
- Switched control provides convenient local operation.
- Flush mounting keeps fixed wiring concealed.
- Secure terminals support dependable connections.
- The matching frame completes the installed finish.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Local Power Control
The integrated control mechanism provides convenient switching or connection for the specified fixed electrical circuit.
Rated Current
45A is the documented current rating for the stated outlet or connection-unit configuration.
Secure Cable Termination
The terminal arrangement supports dependable fixed-wiring connections when correctly installed.
Flush Installation
The concealed mounting arrangement keeps permanent wiring behind the finished wall surface.
Millenium System Coordination
The mechanism and decorative finish coordinate with compatible ABB Millenium frames and accessories.
Key Specifications
Custom Stock Status
In Stock
Weight
0.36 kg
Color
Mocha Brown
Quantity Unit
PCS
Model No
AM118147-MO
Brands
ABB
Item Type
Cooker Switch
Number of Gang
2 Gang
Pole
2 Pole
Rated Current
45A
Rated Voltage
250V AC
Connector Type
BS 13A Switched Socket Outlet
Dimension
42 x 147 x 86 mm
Switch Type
Cooker Control Switch and Switched Socket
Height
86 mm
Width
147 mm
Depth
42 mm
Usage
Cooker isolation with auxiliary 13A socket
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Millenium 45A Cooker Control Unit with 13A Switched Socket AM118147-MO?
The ABB Millenium AM118147-MO is a flush-mounted, 2-gang cooker control unit combining a 45A cooker switch with a BS-type 13A switched socket outlet. It provides local isolation for a fixed cooking appliance while offering a separate socket for a suitable portable appliance. The mocha brown finish coordinates with compatible ABB Millenium frames and accessories.
Why choose the mocha brown ABB Millenium cooker control unit for interior projects?
The mocha brown finish offers a coordinated appearance for kitchens using dark timber, stone, bronze or earth-toned finishes. Its flush-mounted format conceals fixed wiring and creates a neat final installation. For visual consistency across a UAE fit-out project, confirm the availability of matching ABB Millenium switches, sockets, frames and accessories before procurement.
What should be checked during testing and handover?
The contractor should verify terminal tightness, protective-conductor continuity, insulation resistance, polarity, circuit protection, earth-fault-loop performance and correct operation of both switches. Labels, circuit schedules and test records should be updated as required. The ABB Millenium frame should sit evenly against the finished surface, and there should be no exposed conductors, damaged insulation, overheating or loose movement.
Can this cooker control unit be used in villas, apartments and commercial kitchens?
It is suitable for consideration in villas, apartments, staff accommodation and similar fitted-kitchen projects where a 45A local cooker control and BS 13A switched socket are specified. Commercial kitchen suitability depends on the equipment load, duty cycle, environmental conditions and consultant-approved design. Heavy-duty catering equipment may require industrial isolators, contactors or higher-rated connection systems.
Which standards should be checked for a UAE construction project?
The complete installation should follow the current regulations of the relevant UAE authority, such as DEWA, ADDC or the applicable emirate utility, together with project specifications and recognised wiring standards. For product approval, verify the markings and manufacturer documentation for the cooker control unit and BS-pattern 13A socket, including any applicable BS or IEC standards. Do not infer certification solely from the product description.
Is the ABB AM118147-MO suitable for outdoor or wet-area installation?
The listed specifications identify a flush-mounted indoor wiring accessory but do not state an ingress-protection rating. It should not be installed outdoors, in exposed locations or where it may be affected by water, condensation, excessive heat or dust unless the complete enclosure is specifically rated for those conditions. For demanding locations, consult the electrical designer and verify the manufacturer's IP and environmental data.
Where should a cooker control switch be positioned in a kitchen?
It should be readily accessible for normal switching and emergency isolation without requiring a user to reach directly over a hot hob or cooking surface. Positioning must also account for heat, steam, water sources, cabinet layouts and appliance-manufacturer instructions. Final mounting height and location should follow the approved project drawings, accessibility requirements and applicable UAE electrical regulations.
Does the cooker control unit provide overload or earth-leakage protection?
No. A cooker control unit is a local switching and isolation accessory; it does not replace the distribution-board circuit breaker, fuse, RCD or RCBO. Appropriate overcurrent and additional protection must be provided as required by the circuit design, appliance instructions and UAE authority regulations.
What cable and circuit breaker should be used with this 45A cooker switch?
Cable and protective-device selection cannot be determined from the 45A accessory rating alone. The electrician must consider the cooker's connected load, allowable diversity, cable material, conductor size, route length, installation method, ambient temperature, grouping, voltage drop and earth-fault conditions. The circuit breaker and any RCD or RCBO protection should comply with the applicable UAE electrical regulations and the requirements of the relevant local authority.
What flush box and wall space are required for installation?
The control unit is approximately 147 mm wide, 86 mm high and 42 mm deep, so the selected back box must provide adequate depth, fixing compatibility and cable-bending space. Allow additional room for 45A circuit conductors, which can be relatively stiff. Confirm the required ABB Millenium frame and box configuration before cutting blockwork, gypsum board, joinery or kitchen backsplash finishes.
How is the ABB Millenium cooker control unit installed?
Installation should be completed with the electrical supply isolated and proven dead. A qualified electrician should confirm the compatible flush box and ABB Millenium frame, route the dedicated circuit conductors, terminate line, neutral and protective earth connections according to the marked terminals and wiring diagram, tighten terminals to the manufacturer's specified torque, fit the mechanism and frame, and then complete continuity, insulation-resistance, polarity, earth-fault-loop and functional tests before energising.
Can the integrated 13A switched socket power the cooker?
The 13A socket is normally intended for a separate portable appliance with a compatible fused BS plug, not for a cooker requiring a dedicated high-current connection. The 45A switch controls the fixed cooker circuit, while the socket is a separate outlet. Circuit arrangement and load distribution should be confirmed from the product wiring diagram and by the installing electrician.
What cooking appliances can be connected to the 45A cooker control switch?
The switch is intended for a dedicated fixed cooking-appliance circuit, such as an electric cooker, built-in oven, hob or range, provided the appliance demand and circuit design do not exceed the unit's 45A rating. The appliance nameplate, manufacturer instructions and calculated connected load must be reviewed before selection. High-load appliances should never be connected based only on the switch rating.
Is this 45A cooker switch suitable for UAE kitchens?
It is relevant to UAE residential and commercial kitchen projects because UAE low-voltage installations commonly operate at 230V, 50Hz and frequently use British-pattern 13A socket outlets. Its 250V AC rating is compatible with this nominal supply, subject to correct circuit design. The appliance load, cable size, breaker rating, installation method and local authority requirements must be checked by a UAE-licensed electrical contractor before installation.
What are the main technical specifications of this ABB cooker control unit?
The unit has a rated current of 45A for the cooker control switch, a rated voltage of 250V AC, and an integrated BS 13A switched socket outlet. It is designed for flush mounting and measures approximately 42 x 147 x 86 mm. Secure terminals support fixed-wiring connections when the product is installed with correctly sized conductors and suitable protective devices.
Frequently Asked Questions
The ABB Millenium AM118147-MO is a flush-mounted, 2-gang cooker control unit combining a 45A cooker switch with a BS-type 13A switched socket outlet. It provides local isolation for a fixed cooking appliance while offering a separate socket for a suitable portable appliance. The mocha brown finish coordinates with compatible ABB Millenium frames and accessories.
The mocha brown finish offers a coordinated appearance for kitchens using dark timber, stone, bronze or earth-toned finishes. Its flush-mounted format conceals fixed wiring and creates a neat final installation. For visual consistency across a UAE fit-out project, confirm the availability of matching ABB Millenium switches, sockets, frames and accessories before procurement.
The contractor should verify terminal tightness, protective-conductor continuity, insulation resistance, polarity, circuit protection, earth-fault-loop performance and correct operation of both switches. Labels, circuit schedules and test records should be updated as required. The ABB Millenium frame should sit evenly against the finished surface, and there should be no exposed conductors, damaged insulation, overheating or loose movement.
It is suitable for consideration in villas, apartments, staff accommodation and similar fitted-kitchen projects where a 45A local cooker control and BS 13A switched socket are specified. Commercial kitchen suitability depends on the equipment load, duty cycle, environmental conditions and consultant-approved design. Heavy-duty catering equipment may require industrial isolators, contactors or higher-rated connection systems.
The complete installation should follow the current regulations of the relevant UAE authority, such as DEWA, ADDC or the applicable emirate utility, together with project specifications and recognised wiring standards. For product approval, verify the markings and manufacturer documentation for the cooker control unit and BS-pattern 13A socket, including any applicable BS or IEC standards. Do not infer certification solely from the product description.
The listed specifications identify a flush-mounted indoor wiring accessory but do not state an ingress-protection rating. It should not be installed outdoors, in exposed locations or where it may be affected by water, condensation, excessive heat or dust unless the complete enclosure is specifically rated for those conditions. For demanding locations, consult the electrical designer and verify the manufacturer's IP and environmental data.
It should be readily accessible for normal switching and emergency isolation without requiring a user to reach directly over a hot hob or cooking surface. Positioning must also account for heat, steam, water sources, cabinet layouts and appliance-manufacturer instructions. Final mounting height and location should follow the approved project drawings, accessibility requirements and applicable UAE electrical regulations.
No. A cooker control unit is a local switching and isolation accessory; it does not replace the distribution-board circuit breaker, fuse, RCD or RCBO. Appropriate overcurrent and additional protection must be provided as required by the circuit design, appliance instructions and UAE authority regulations.
Cable and protective-device selection cannot be determined from the 45A accessory rating alone. The electrician must consider the cooker's connected load, allowable diversity, cable material, conductor size, route length, installation method, ambient temperature, grouping, voltage drop and earth-fault conditions. The circuit breaker and any RCD or RCBO protection should comply with the applicable UAE electrical regulations and the requirements of the relevant local authority.
The control unit is approximately 147 mm wide, 86 mm high and 42 mm deep, so the selected back box must provide adequate depth, fixing compatibility and cable-bending space. Allow additional room for 45A circuit conductors, which can be relatively stiff. Confirm the required ABB Millenium frame and box configuration before cutting blockwork, gypsum board, joinery or kitchen backsplash finishes.
Installation should be completed with the electrical supply isolated and proven dead. A qualified electrician should confirm the compatible flush box and ABB Millenium frame, route the dedicated circuit conductors, terminate line, neutral and protective earth connections according to the marked terminals and wiring diagram, tighten terminals to the manufacturer's specified torque, fit the mechanism and frame, and then complete continuity, insulation-resistance, polarity, earth-fault-loop and functional tests before energising.
The 13A socket is normally intended for a separate portable appliance with a compatible fused BS plug, not for a cooker requiring a dedicated high-current connection. The 45A switch controls the fixed cooker circuit, while the socket is a separate outlet. Circuit arrangement and load distribution should be confirmed from the product wiring diagram and by the installing electrician.
The switch is intended for a dedicated fixed cooking-appliance circuit, such as an electric cooker, built-in oven, hob or range, provided the appliance demand and circuit design do not exceed the unit's 45A rating. The appliance nameplate, manufacturer instructions and calculated connected load must be reviewed before selection. High-load appliances should never be connected based only on the switch rating.
It is relevant to UAE residential and commercial kitchen projects because UAE low-voltage installations commonly operate at 230V, 50Hz and frequently use British-pattern 13A socket outlets. Its 250V AC rating is compatible with this nominal supply, subject to correct circuit design. The appliance load, cable size, breaker rating, installation method and local authority requirements must be checked by a UAE-licensed electrical contractor before installation.
The unit has a rated current of 45A for the cooker control switch, a rated voltage of 250V AC, and an integrated BS 13A switched socket outlet. It is designed for flush mounting and measures approximately 42 x 147 x 86 mm. Secure terminals support fixed-wiring connections when the product is installed with correctly sized conductors and suitable protective devices.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy