FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- RJ45 Cat 5E supports structured network links.
- One-gang layout suits organized cabling.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- The clean faceplate suits modern interiors.
- Starry Black finish supports coordinated wall fittings.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
1 Gang RJ45 Cat 5E Data Outlet from the ABB Inora wiring-accessory range.
Model
BL331-885 identifies the starry black finish variant.
Configuration
1 Gang configuration is designed for ethernet network connections.
Connector Type
RJ45 Cat 5E provides the stated communication or signal interface.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 5733 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in Starry Black suit ethernet network connections in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
Starry Black
Quantity Unit
PCS
Model No
BL331-885
Brands
ABB
Item Type
Data Socket
Number of Gang
1 Gang
Connector Type
RJ45 Cat 5E
Dimension
86 x 38.8 x 86 mm
Height
86 mm
Width
38.8 mm
Depth
86 mm
Usage
Ethernet Network Connections
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 1 Gang CAT.5e Data Socket Starry Black BL331-885?
The ABB Inora BL331-885 is a single-gang Category 5e data socket designed to provide a fixed network connection point for Ethernet cabling. It combines ABB Inora styling with a Starry Black finish, making it suitable for modern offices, homes, hotels, retail units and other UAE construction or fit-out projects requiring one wired data outlet.
What network speeds can the ABB Inora CAT.5e data socket support?
When correctly terminated as part of a compliant Category 5e channel, the socket can support Ethernet applications up to 1 Gigabit per second, subject to the connected cable, patch panel, patch cords, network equipment and total channel length. Final performance depends on the entire structured cabling system rather than the outlet alone.
Which Ethernet cable should be used with the ABB Inora BL331-885 socket?
Use a genuine Category 5e or higher-rated four-pair copper data cable that matches the project specification. Solid-conductor cable is normally used for permanent building links, while stranded patch cords are used between the outlet and connected device. Cable conductor size, shielding arrangement and fire-performance rating should be confirmed against the socket termination requirements and UAE project documents.
How is the ABB Inora 1 Gang CAT.5e data socket installed?
Isolate nearby electrical circuits, install the compatible wall box or mounting enclosure, route the data cable without crushing or sharp bends, remove only the necessary outer sheath and terminate each conductor according to the outlet markings. Maintain the pair twists as close as possible to the termination, secure the cable without excessive pressure, fit the socket into the box and test the completed link before handover. Installation should be completed by a qualified ELV or structured-cabling technician.
Should T568A or T568B wiring be used for this CAT.5e socket?
Either T568A or T568B may be used if supported by the terminal colour code, but the same scheme must be maintained at both ends of the cable. T568B is common in many commercial installations, although the approved consultant specification and existing site standard should always take priority. Mixing T568A and T568B unintentionally creates a crossover configuration and may cause commissioning issues.
What installation practices help maintain Category 5e performance?
Keep data cables separated from mains power cables according to the approved project specification, avoid tight bends and over-tensioning, do not untwist conductor pairs more than necessary and keep the permanent link within the applicable structured-cabling length limits. Avoid running the cable close to transformers, motors, variable-frequency drives and other electromagnetic interference sources. Proper containment, labelling, termination and field testing are essential for reliable performance.
Can the ABB Inora CAT.5e socket be used for PoE devices?
It may form part of a Power over Ethernet link for devices such as IP phones, wireless access points and compatible cameras, provided the complete cabling channel, terminations and network equipment support the required IEEE PoE standard and power level. For higher-power PoE applications or large cable bundles, cable category, conductor size, temperature rise and project requirements should be reviewed by the network designer.
Is this ABB Inora data socket suitable for UAE homes and offices?
Yes, it is suitable for indoor structured-network installations in UAE villas, apartments, offices, hotels, shops and similar buildings where a single wired Ethernet point is required. The Starry Black finish can coordinate with dark interior accessories. For hot, humid, dusty or exposed locations, use a suitable rated enclosure and verify the environmental requirements, as a standard indoor data outlet should not be assumed to be weatherproof.
Can the socket be installed near an electrical power outlet?
It can be positioned in the same room or workstation area as a power outlet, but data and power wiring should remain correctly segregated. Where combined service boxes or shared trunking systems are used, approved partitions and separate compartments should be provided as required by the project specification and applicable electrical and ELV practices. This helps reduce interference and supports safer maintenance.
Is the ABB Inora BL331-885 suitable for commercial construction and fit-out projects?
Yes, the outlet is relevant to office fit-outs, hospitality projects, retail spaces, residential developments and other construction applications requiring a single CAT.5e data point. Before bulk procurement, contractors should confirm compatibility with the specified ABB Inora plates, mounting boxes, cable type, colour schedule, bill of quantities and consultant-approved structured cabling system.
Which standards should be considered when installing this CAT.5e data outlet in the UAE?
The completed structured cabling installation should follow the approved project specification and applicable standards such as ISO/IEC 11801 and ANSI/TIA-568, where specified. UAE authority requirements, the relevant emirate's building and electrical regulations, and UAE Fire and Life Safety Code requirements for cable fire performance and penetrations may also apply. Approval obligations vary by project, so contractors should verify them with the consultant and relevant authority.
How should the installed CAT.5e data point be tested?
At minimum, test wire map, continuity, pair arrangement and connection faults. For formal project handover, use a calibrated field cable certifier to verify the permanent link or channel against the specified Category 5e limit, including parameters such as insertion loss, return loss and crosstalk. Each outlet should be labelled and its test result linked to the corresponding patch-panel port.
What is the recommended maximum cable length for a CAT.5e network point?
A standards-based copper Ethernet channel is generally limited to 100 metres, typically comprising up to 90 metres of permanent horizontal cable plus patch cords and equipment cords within the remaining allowance. Design teams should account for routing, consolidation points and patch-cord lengths before installation rather than measuring only the direct distance between rooms.
Can this 1 Gang CAT.5e socket be used for telephone or IP phone connections?
It is primarily intended as an Ethernet data outlet and is well suited to compatible IP phones connected through an RJ45 network interface. Other low-voltage communication uses depend on the system design and pin assignment. Contractors should not connect incompatible analogue, proprietary or mains-voltage circuits to a data socket without confirming the equipment and cabling requirements.
How should the Starry Black data socket be cleaned and maintained?
Disconnect connected equipment if necessary and wipe the visible surface with a soft, dry or slightly damp cloth. Do not use abrasive pads, aggressive solvents or excessive water, as these may damage the finish or enter the contacts. During periodic network maintenance, inspect the socket for looseness, contamination or physical damage and retest the link if performance problems occur.
Frequently Asked Questions
The ABB Inora BL331-885 is a single-gang Category 5e data socket designed to provide a fixed network connection point for Ethernet cabling. It combines ABB Inora styling with a Starry Black finish, making it suitable for modern offices, homes, hotels, retail units and other UAE construction or fit-out projects requiring one wired data outlet.
When correctly terminated as part of a compliant Category 5e channel, the socket can support Ethernet applications up to 1 Gigabit per second, subject to the connected cable, patch panel, patch cords, network equipment and total channel length. Final performance depends on the entire structured cabling system rather than the outlet alone.
Use a genuine Category 5e or higher-rated four-pair copper data cable that matches the project specification. Solid-conductor cable is normally used for permanent building links, while stranded patch cords are used between the outlet and connected device. Cable conductor size, shielding arrangement and fire-performance rating should be confirmed against the socket termination requirements and UAE project documents.
Isolate nearby electrical circuits, install the compatible wall box or mounting enclosure, route the data cable without crushing or sharp bends, remove only the necessary outer sheath and terminate each conductor according to the outlet markings. Maintain the pair twists as close as possible to the termination, secure the cable without excessive pressure, fit the socket into the box and test the completed link before handover. Installation should be completed by a qualified ELV or structured-cabling technician.
Either T568A or T568B may be used if supported by the terminal colour code, but the same scheme must be maintained at both ends of the cable. T568B is common in many commercial installations, although the approved consultant specification and existing site standard should always take priority. Mixing T568A and T568B unintentionally creates a crossover configuration and may cause commissioning issues.
Keep data cables separated from mains power cables according to the approved project specification, avoid tight bends and over-tensioning, do not untwist conductor pairs more than necessary and keep the permanent link within the applicable structured-cabling length limits. Avoid running the cable close to transformers, motors, variable-frequency drives and other electromagnetic interference sources. Proper containment, labelling, termination and field testing are essential for reliable performance.
It may form part of a Power over Ethernet link for devices such as IP phones, wireless access points and compatible cameras, provided the complete cabling channel, terminations and network equipment support the required IEEE PoE standard and power level. For higher-power PoE applications or large cable bundles, cable category, conductor size, temperature rise and project requirements should be reviewed by the network designer.
Yes, it is suitable for indoor structured-network installations in UAE villas, apartments, offices, hotels, shops and similar buildings where a single wired Ethernet point is required. The Starry Black finish can coordinate with dark interior accessories. For hot, humid, dusty or exposed locations, use a suitable rated enclosure and verify the environmental requirements, as a standard indoor data outlet should not be assumed to be weatherproof.
It can be positioned in the same room or workstation area as a power outlet, but data and power wiring should remain correctly segregated. Where combined service boxes or shared trunking systems are used, approved partitions and separate compartments should be provided as required by the project specification and applicable electrical and ELV practices. This helps reduce interference and supports safer maintenance.
Yes, the outlet is relevant to office fit-outs, hospitality projects, retail spaces, residential developments and other construction applications requiring a single CAT.5e data point. Before bulk procurement, contractors should confirm compatibility with the specified ABB Inora plates, mounting boxes, cable type, colour schedule, bill of quantities and consultant-approved structured cabling system.
The completed structured cabling installation should follow the approved project specification and applicable standards such as ISO/IEC 11801 and ANSI/TIA-568, where specified. UAE authority requirements, the relevant emirate's building and electrical regulations, and UAE Fire and Life Safety Code requirements for cable fire performance and penetrations may also apply. Approval obligations vary by project, so contractors should verify them with the consultant and relevant authority.
At minimum, test wire map, continuity, pair arrangement and connection faults. For formal project handover, use a calibrated field cable certifier to verify the permanent link or channel against the specified Category 5e limit, including parameters such as insertion loss, return loss and crosstalk. Each outlet should be labelled and its test result linked to the corresponding patch-panel port.
A standards-based copper Ethernet channel is generally limited to 100 metres, typically comprising up to 90 metres of permanent horizontal cable plus patch cords and equipment cords within the remaining allowance. Design teams should account for routing, consolidation points and patch-cord lengths before installation rather than measuring only the direct distance between rooms.
It is primarily intended as an Ethernet data outlet and is well suited to compatible IP phones connected through an RJ45 network interface. Other low-voltage communication uses depend on the system design and pin assignment. Contractors should not connect incompatible analogue, proprietary or mains-voltage circuits to a data socket without confirming the equipment and cabling requirements.
Disconnect connected equipment if necessary and wipe the visible surface with a soft, dry or slightly damp cloth. Do not use abrasive pads, aggressive solvents or excessive water, as these may damage the finish or enter the contacts. During periodic network maintenance, inspect the socket for looseness, contamination or physical damage and retest the link if performance problems occur.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy