ABB

ABB Inora 1 Gang RJ45 Cat 6 Data Outlet White BL333

In Stock
33.62
EXCL.VAT
Incl. 5% VAT AED 35.30

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • RJ45 Cat 6 supports structured network links.
    • One-gang layout suits organized cabling.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • The clean faceplate suits modern interiors.
    • White finish supports coordinated wall fittings.

Features & Benefits

Product Type

1 Gang RJ45 Cat 6 Data Outlet from the ABB Inora wiring-accessory range.

Model

BL333 identifies the white finish variant.

Configuration

1 Gang configuration is designed for ethernet network connections.

Connector Type

RJ45 Cat 6 provides the stated communication or signal interface.

Installation

Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 5733 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in White suit ethernet network connections in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

White

Quantity Unit

PCS

Model No

BL333

Brands

ABB

Item Type

Data Socket

Number of Gang

1 Gang

Connector Type

RJ45 Cat 6

Dimension

86 x 38.8 x 86 mm

Height

86 mm

Width

38.8 mm

Depth

86 mm

Usage

Ethernet Network Connections

Installation Type

Flush Mounted

Frequently Asked Questions

Yes, it is suitable for structured cabling points in UAE residential and commercial interiors when installed as part of a compatible CAT6 system. Common uses include home networks, workstations, meeting rooms, smart-home hubs, Wi-Fi access points, IP phones and IP surveillance equipment. For major projects, confirm the approved brand, cabling category and submittal requirements with the consultant.

Keep the outlet dry and free from construction dust, paint and plaster. Clean the faceplate with a soft, lightly damp cloth after isolating connected equipment, and avoid solvents or abrasive cleaners. Inspect loose fittings or damaged ports during maintenance and retest the data link if connectivity becomes intermittent.

Common causes include incorrect T568A or T568B termination, excessive untwisting of conductor pairs, damaged cable, tight bends, poor-quality patch leads, excessive cable length, electrical interference, incompatible components or a fault in the router or switch. Recheck the wire map and certify the permanent link before replacing the socket.

At minimum, use a cable tester to check continuity, wire map, opens, shorts, reversals and split pairs. For commercial projects requiring CAT6 certification, use a calibrated field certification tester to measure parameters such as insertion loss, return loss, propagation delay and crosstalk. Retain test reports and outlet labels for handover documentation.

This type of white decorative data socket is generally intended for dry indoor locations. For balconies, gardens, construction-site cabins, plant areas or other locations exposed to dust, moisture, heat or sunlight, use an appropriately rated weatherproof enclosure and confirm the required IP rating and environmental suitability.

It can form part of a Power over Ethernet link for compatible equipment such as IP cameras, VoIP phones and wireless access points, provided the complete channel uses compliant CAT6 components and the cable, connectors, patch panel, patch leads and network switch support the required PoE standard and power level. Cable bundling, heat rise and installation conditions must also be considered.

The complete structured cabling installation should follow the consultant's specification and relevant standards such as ISO/IEC 11801 and ANSI/TIA-568.2-D, together with applicable UAE electrical, fire-safety, telecom and local authority requirements. Project-specific requirements from the relevant emirate, developer or service provider should also be checked before installation.

A data outlet may be positioned near a power outlet for user convenience, but the data and power cabling must be routed and segregated according to applicable electrical, structured cabling and project requirements. Separate containment or approved partitions may be required. Avoid parallel runs close to mains cables where electromagnetic interference could affect network performance.

Yes. The single-gang format is practical for new construction, renovation and fit-out works that require one dedicated network outlet. Contractors should coordinate outlet locations with architectural drawings, furniture layouts, IT requirements and MEP services before closing walls or ceilings.

The ABB Inora BL333 is a single-gang Category 6 data outlet designed to provide a dedicated wired network connection in residential, commercial and construction projects. Its white finish suits modern interiors, while the 1-gang configuration makes it suitable for individual data points in offices, villas, apartments, shops, hotels and other UAE properties.

The product is intended for a 1-gang installation, but back-box dimensions, mounting centres, depth and compatibility should be checked against the ABB Inora accessory system and the box used on the project. Adequate depth is important because CAT6 cable must not be sharply bent or compressed behind the outlet.

Maintain the cable manufacturer's minimum bend radius, do not over-tighten cable ties, avoid kinks and compression, and keep conductor pairs twisted up to the termination. Keep data cables separated from power circuits and sources of electromagnetic interference, use suitable containment, avoid exceeding pulling-tension limits, and do not create unnecessary joints. Each completed data point should be identified and tested.

Either T568A or T568B may be used if permitted by the project specification, but the same wiring scheme must be applied at both ends of the cable. T568B is widely encountered in commercial installations, while some projects specify T568A. Contractors should follow the consultant-approved structured cabling schedule and label every outlet consistently.

Route the CAT6 cable to a compatible concealed or surface-mounted back box, leaving enough cable for termination without excessive slack. Remove only the necessary outer sheath, preserve the pair twists as close as possible to the termination point, arrange conductors according to the selected T568A or T568B scheme, terminate them with the appropriate tool, secure the cable without crushing it, fit the socket and faceplate, and test the completed link with a suitable network cable tester.

Use genuine solid-conductor CAT6 installation cable of the appropriate type for the project, such as U/UTP or a screened construction where required by the design. Cable conductor size, screening arrangement and termination compatibility should be confirmed before installation. Avoid mixing lower-category cable or accessories because the link is only rated according to its lowest-performing component.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy