ABB Inora 2 Gang 13A Double Pole Switched Socket Outlet with Illumination Classic Grey BL240-G
FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- The 13A rating suits appliance power loads.
- Two-gang double pole switching controls supply.
- Safety shutters help guard live socket contacts.
- Illumination helps locate the socket at night.
- Polycarbonate parts support durable daily use.
- Classic Grey finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
2 Gang Switched Socket Double Pole with Illumination from the ABB Inora wiring-accessory range.
Model
BL240-G identifies the classic grey finish variant.
Configuration
2 Gang Double Pole configuration is designed for switched appliance power connection.
Electrical Rating
13A at 250V AC supports the stated fixed-wiring application.
Indicator
Illuminated provides visible identification or easier location in low light.
Installation
Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Socket Safety
The Inora socket design uses safety shutters to help protect users from accidental access to live contacts.
Standard Compliance
BS 1363-2; SS 145-2; SASO 2203; MS 589-2 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in Classic Grey suit switched appliance power connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
Classic Grey
Quantity Unit
PCS
Model No
BL240-G
Brands
ABB
Item Type
Double Socket
Number of Gang
2 Gang
Pole
2 Pole
Rated Current
13A
Rated Voltage
250V AC
Dimension
86 x 30.8 x 146 mm
Switch Type
Switched Socket
Height
146 mm
Width
30.8 mm
Depth
86 mm
Usage
Switched appliance power connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 13A DP Double Switched Socket with Neon BL240-G?
The ABB Inora BL240-G is a double 13A switched wall socket from the Inora range, finished in Classic Grey. It provides two outlets for compatible 13A plugs, individual switching, double-pole isolation and neon indicators that provide a visible indication of switch status. It is suitable for residential, commercial and general construction electrical installations.
What does DP mean on this ABB Inora 13A socket?
DP means double pole. Each double-pole switch is designed to disconnect both the live and neutral conductors when switched off, providing more complete isolation than a single-pole switch. Correct earthing and circuit isolation are still essential, and installation should be completed by a qualified electrician.
What is the purpose of the neon indicators on the BL240-G socket?
The neon indicators provide a convenient visual indication of the socket switch status. This can be useful in homes, offices, workshops, utility rooms and commercial spaces where users need to identify whether an outlet has been switched on. Indicator operation depends on correct wiring in accordance with the manufacturer's instructions.
Where can the ABB Inora BL240-G double socket be used?
This socket is intended for suitable indoor electrical installations, including villas, apartments, offices, retail units, staff accommodation, workshops and other construction projects. It can supply compatible appliances and equipment within the circuit and socket ratings. It should not be installed outdoors, in wet areas or in exposed locations unless it is housed within an appropriately rated weatherproof enclosure.
Is the ABB Inora BL240-G suitable for UAE construction projects?
The 13A switched-socket format is widely used in UAE residential and commercial buildings. Project engineers should confirm that the product markings, technical documentation and installation method satisfy the applicable UAE electrical regulations, project specifications and requirements of the relevant local authority, such as DEWA, ADDC, SEWA or the authority having jurisdiction.
How is the ABB Inora 13A DP double switched socket installed?
Before installation, isolate the circuit at the distribution board and verify that it is de-energised. A qualified electrician should connect the live, neutral and earth conductors to the clearly identified terminals, secure the conductors to the manufacturer's specified torque, fit the socket to a compatible back box and check that no wires are trapped. The circuit should then undergo continuity, insulation resistance, polarity, earthing and functional tests before energisation.
What back box is required for the ABB Inora BL240-G?
Use a back box that matches the socket's mounting pattern, overall dimensions and required wiring depth. The box must provide adequate space for cable bends, terminals and earth continuity without crushing or sharply bending conductors. Confirm the exact box dimensions and minimum depth from the ABB Inora technical data or approved project submittal before installation.
Can both outlets on this ABB double socket be used simultaneously?
Both outlets may be used at the same time, provided the connected loads remain within the socket rating, circuit design capacity and protective-device limits. The 13A marking must not be interpreted as permission to overload the final circuit. High-load appliances, extension leads and multi-plug adaptors should be assessed carefully by a qualified electrician.
Can the BL240-G socket be used for air conditioners, water heaters or other fixed equipment?
Do not select this socket solely because an appliance plug fits it. Air conditioners, water heaters, cookers and other high-load or fixed appliances may require a dedicated circuit, local isolator, fused connection unit or higher-rated accessory. The appliance manufacturer's instructions, calculated load, cable size and UAE project requirements should determine the correct connection method.
What electrical protection should be provided for this 13A switched socket?
The socket circuit should have correctly selected overcurrent and earth-leakage protection based on the circuit type, cable size, installation method and applicable regulations. Proper earthing is mandatory. RCD or RCBO protection may be required depending on the location and governing electrical rules, so circuit design and testing should be handled by a qualified electrical professional.
Is the ABB Inora Classic Grey socket suitable for kitchens, bathrooms or outdoor areas?
Suitability depends on the installation zone and exposure to moisture, dust and heat. A standard indoor socket should not be exposed directly to water, condensation or outdoor weather. Kitchens, bathrooms, balconies, landscaping areas and construction-site locations may require additional separation, RCD protection or an accessory with a suitable IP rating. Always follow local regulations and project specifications.
What should contractors check before specifying the ABB Inora BL240-G?
Contractors should verify the model number BL240-G, Classic Grey finish, socket configuration, rated current, voltage and frequency markings, terminal capacity, back-box compatibility, applicable conformity markings and availability of technical documentation. The selected accessory should also match the project's wiring system, interior finish schedule and approved electrical material submittal.
How should the ABB Inora 13A double switched socket be maintained?
Keep the faceplate clean and dry, using a soft cloth without abrasive or solvent-based cleaners. Periodically check for discoloration, cracking, unusual heat, buzzing, loose operation or damaged switches. If any defect is found, isolate the circuit and arrange inspection by a qualified electrician. Internal terminals should not be accessed while the circuit is energised.
Why choose an ABB Inora double switched socket for a building project?
The ABB Inora BL240-G combines two individually switched 13A outlets, double-pole switching, visible neon indication and a Classic Grey finish in one wall accessory. This configuration supports practical power access and coordinated interior design in UAE homes, offices and commercial developments, subject to correct specification, installation and regulatory approval.
Frequently Asked Questions
The ABB Inora BL240-G is a double 13A switched wall socket from the Inora range, finished in Classic Grey. It provides two outlets for compatible 13A plugs, individual switching, double-pole isolation and neon indicators that provide a visible indication of switch status. It is suitable for residential, commercial and general construction electrical installations.
DP means double pole. Each double-pole switch is designed to disconnect both the live and neutral conductors when switched off, providing more complete isolation than a single-pole switch. Correct earthing and circuit isolation are still essential, and installation should be completed by a qualified electrician.
The neon indicators provide a convenient visual indication of the socket switch status. This can be useful in homes, offices, workshops, utility rooms and commercial spaces where users need to identify whether an outlet has been switched on. Indicator operation depends on correct wiring in accordance with the manufacturer's instructions.
This socket is intended for suitable indoor electrical installations, including villas, apartments, offices, retail units, staff accommodation, workshops and other construction projects. It can supply compatible appliances and equipment within the circuit and socket ratings. It should not be installed outdoors, in wet areas or in exposed locations unless it is housed within an appropriately rated weatherproof enclosure.
The 13A switched-socket format is widely used in UAE residential and commercial buildings. Project engineers should confirm that the product markings, technical documentation and installation method satisfy the applicable UAE electrical regulations, project specifications and requirements of the relevant local authority, such as DEWA, ADDC, SEWA or the authority having jurisdiction.
Before installation, isolate the circuit at the distribution board and verify that it is de-energised. A qualified electrician should connect the live, neutral and earth conductors to the clearly identified terminals, secure the conductors to the manufacturer's specified torque, fit the socket to a compatible back box and check that no wires are trapped. The circuit should then undergo continuity, insulation resistance, polarity, earthing and functional tests before energisation.
Use a back box that matches the socket's mounting pattern, overall dimensions and required wiring depth. The box must provide adequate space for cable bends, terminals and earth continuity without crushing or sharply bending conductors. Confirm the exact box dimensions and minimum depth from the ABB Inora technical data or approved project submittal before installation.
Both outlets may be used at the same time, provided the connected loads remain within the socket rating, circuit design capacity and protective-device limits. The 13A marking must not be interpreted as permission to overload the final circuit. High-load appliances, extension leads and multi-plug adaptors should be assessed carefully by a qualified electrician.
Do not select this socket solely because an appliance plug fits it. Air conditioners, water heaters, cookers and other high-load or fixed appliances may require a dedicated circuit, local isolator, fused connection unit or higher-rated accessory. The appliance manufacturer's instructions, calculated load, cable size and UAE project requirements should determine the correct connection method.
The socket circuit should have correctly selected overcurrent and earth-leakage protection based on the circuit type, cable size, installation method and applicable regulations. Proper earthing is mandatory. RCD or RCBO protection may be required depending on the location and governing electrical rules, so circuit design and testing should be handled by a qualified electrical professional.
Suitability depends on the installation zone and exposure to moisture, dust and heat. A standard indoor socket should not be exposed directly to water, condensation or outdoor weather. Kitchens, bathrooms, balconies, landscaping areas and construction-site locations may require additional separation, RCD protection or an accessory with a suitable IP rating. Always follow local regulations and project specifications.
Contractors should verify the model number BL240-G, Classic Grey finish, socket configuration, rated current, voltage and frequency markings, terminal capacity, back-box compatibility, applicable conformity markings and availability of technical documentation. The selected accessory should also match the project's wiring system, interior finish schedule and approved electrical material submittal.
Keep the faceplate clean and dry, using a soft cloth without abrasive or solvent-based cleaners. Periodically check for discoloration, cracking, unusual heat, buzzing, loose operation or damaged switches. If any defect is found, isolate the circuit and arrange inspection by a qualified electrician. Internal terminals should not be accessed while the circuit is energised.
The ABB Inora BL240-G combines two individually switched 13A outlets, double-pole switching, visible neon indication and a Classic Grey finish in one wall accessory. This configuration supports practical power access and coordinated interior design in UAE homes, offices and commercial developments, subject to correct specification, installation and regulatory approval.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy