FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- The 13A rating suits appliance power loads.
- One-gang double pole switching controls supply.
- Safety shutters help guard live socket contacts.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- White finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
1 Gang Switched Socket Double Pole from the ABB Inora wiring-accessory range.
Model
BL237 identifies the white finish variant.
Configuration
1 Gang Double Pole configuration is designed for switched appliance power connection.
Electrical Rating
13A at 250V AC supports the stated fixed-wiring application.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Socket Safety
The Inora socket design uses safety shutters to help protect users from accidental access to live contacts.
Standard Compliance
BS 1363-2; SS 145-2; SASO 2203; MS 589-2 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit switched appliance power connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL237
Brands
ABB
Item Type
Single Socket
Number of Gang
1 Gang
Pole
2 Pole
Rated Current
13A
Rated Voltage
250V AC
Dimension
86 x 30.3 x 86 mm
Switch Type
Switched Socket
Height
86 mm
Width
30.3 mm
Depth
86 mm
Usage
Switched appliance power connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 13A DP Single Switched Socket White BL237?
The ABB Inora BL237 is a white, single-gang 13A switched socket outlet designed for connecting one compatible appliance or electrical device. Its double-pole switching mechanism isolates both the live and neutral conductors when switched off, providing more complete isolation than a single-pole switch. It is suitable for residential, commercial and construction fit-out applications where a standard UK-style 13A socket is specified.
What does DP mean on the ABB Inora BL237 socket?
DP means double pole. When the socket switch is turned off, it disconnects both the live and neutral conductors. This feature is useful in UAE electrical installations because it provides enhanced isolation for connected equipment, particularly during cleaning, servicing or periods when an appliance is not being used.
Is the ABB Inora BL237 suitable for UAE electrical installations?
The BL237 is designed for 13A socket applications commonly used with the UAE's nominal 230V, 50Hz electrical supply. Project consultants and contractors should verify the socket specification against the approved electrical drawings, applicable BS 1363 requirements and the regulations of the relevant UAE authority, such as DEWA, ADDC or another local utility. Final suitability depends on the complete circuit design and project approval.
What appliances can be connected to this ABB 13A switched socket?
It can be used for compatible plug-in equipment with a current demand within the socket and circuit rating, including computers, televisions, chargers, small kitchen appliances and general office equipment. High-load appliances must be checked using their nameplate wattage and current. Equipment that requires a dedicated circuit, fused connection unit or isolator should not be connected merely because it has a compatible plug.
Can the ABB Inora BL237 be used in residential and commercial construction projects?
Yes. The socket is suitable for common indoor fit-out requirements in villas, apartments, offices, retail spaces, hotels and other commercial properties, subject to consultant approval. Its white finish works well with many standard interior schemes, while the single-socket format is useful where only one controlled outlet is required.
How is the ABB Inora 13A DP single switched socket installed?
Installation should be completed by a licensed electrician. The circuit must first be isolated, locked out where required and tested to confirm it is dead. The live, neutral and earth conductors should then be identified, terminated at the correctly marked terminals and tightened to the manufacturer's specified torque. The socket should be secured to a compatible wall box without trapping conductors, after which continuity, polarity, insulation resistance, earth-fault protection and functional operation should be tested.
What wall box and wiring accessories are required for installing the BL237?
A compatible single-gang flush or surface mounting box with suitable fixing centres and adequate depth is required. Box depth should allow safe conductor bending and terminal clearance. Cable size, protective device rating, earthing arrangement and RCD or RCBO protection must follow the approved circuit design and applicable UAE electrical regulations. Compatibility should be checked before bulk procurement for a project.
Does the ABB Inora BL237 require earthing?
Yes. The protective earth conductor must be connected to the designated earth terminal, and any metal back box should also be correctly bonded where required. Effective earthing is essential for fault protection. The electrician must test earth continuity and confirm that the circuit's protective device will disconnect within the required time under fault conditions.
Can this 13A switched socket be installed in kitchens, bathrooms or outdoor areas?
Its use depends on the installation zone, enclosure protection and local regulations. Because no specific IP rating is provided in the product data, the BL237 should not be assumed to be weatherproof or suitable for direct exposure to water, dust, humidity or outdoor conditions. Wet areas, balconies, gardens and construction sites generally require appropriately rated enclosures, suitable RCD protection and accessories selected for the environmental conditions.
Can the ABB Inora BL237 be used as a replacement for an existing 13A socket?
It may be used as a replacement when the wall box, fixing arrangement, wiring condition, circuit rating and applicable standard are compatible. Before replacement, an electrician should inspect the conductors for heat damage, loose terminations, inadequate earth continuity or insufficient box depth. The circuit must be tested after installation rather than treating the work as a simple faceplate change.
Why is double-pole switching useful for UAE homes and offices?
Double-pole switching isolates both live and neutral at the socket, offering a clear local means of disconnecting connected equipment. This is beneficial for everyday appliance control and maintenance in homes, offices, shops and hospitality properties. It does not replace circuit isolation, however; electricians must still isolate and verify the supply before carrying out electrical work.
Is the ABB Inora 13A socket suitable for construction-site temporary power?
A standard indoor socket should not automatically be used as an exposed temporary site outlet. UAE construction sites can involve dust, moisture, impact and harsh handling, so temporary distribution systems normally require robust industrial accessories, suitable IP ratings, RCD protection and compliance with site safety procedures. The BL237 is better suited to completed indoor fixed installations unless it is housed in a properly designed and approved protective assembly.
How should contractors test the ABB Inora BL237 after installation?
Testing should form part of the complete circuit verification process and include protective conductor continuity, insulation resistance, polarity, earth-fault loop or equivalent protective measures, RCD or RCBO operation where fitted, and a functional check of the double-pole switch. Results should be recorded in the project's inspection and testing documentation in accordance with the consultant's requirements and relevant UAE regulations.
How should the ABB Inora white switched socket be cleaned and maintained?
Switch off and isolate the circuit before inspection or cleaning. Wipe the faceplate with a soft, dry or slightly damp cloth and avoid solvents, abrasive cleaners and water entering the socket apertures. Replace the accessory if there are signs of cracking, discoloration, overheating, arcing, loose mounting or unreliable switching, and have the connected circuit inspected by a qualified electrician.
Frequently Asked Questions
The ABB Inora BL237 is a white, single-gang 13A switched socket outlet designed for connecting one compatible appliance or electrical device. Its double-pole switching mechanism isolates both the live and neutral conductors when switched off, providing more complete isolation than a single-pole switch. It is suitable for residential, commercial and construction fit-out applications where a standard UK-style 13A socket is specified.
DP means double pole. When the socket switch is turned off, it disconnects both the live and neutral conductors. This feature is useful in UAE electrical installations because it provides enhanced isolation for connected equipment, particularly during cleaning, servicing or periods when an appliance is not being used.
The BL237 is designed for 13A socket applications commonly used with the UAE's nominal 230V, 50Hz electrical supply. Project consultants and contractors should verify the socket specification against the approved electrical drawings, applicable BS 1363 requirements and the regulations of the relevant UAE authority, such as DEWA, ADDC or another local utility. Final suitability depends on the complete circuit design and project approval.
It can be used for compatible plug-in equipment with a current demand within the socket and circuit rating, including computers, televisions, chargers, small kitchen appliances and general office equipment. High-load appliances must be checked using their nameplate wattage and current. Equipment that requires a dedicated circuit, fused connection unit or isolator should not be connected merely because it has a compatible plug.
Yes. The socket is suitable for common indoor fit-out requirements in villas, apartments, offices, retail spaces, hotels and other commercial properties, subject to consultant approval. Its white finish works well with many standard interior schemes, while the single-socket format is useful where only one controlled outlet is required.
Installation should be completed by a licensed electrician. The circuit must first be isolated, locked out where required and tested to confirm it is dead. The live, neutral and earth conductors should then be identified, terminated at the correctly marked terminals and tightened to the manufacturer's specified torque. The socket should be secured to a compatible wall box without trapping conductors, after which continuity, polarity, insulation resistance, earth-fault protection and functional operation should be tested.
A compatible single-gang flush or surface mounting box with suitable fixing centres and adequate depth is required. Box depth should allow safe conductor bending and terminal clearance. Cable size, protective device rating, earthing arrangement and RCD or RCBO protection must follow the approved circuit design and applicable UAE electrical regulations. Compatibility should be checked before bulk procurement for a project.
Yes. The protective earth conductor must be connected to the designated earth terminal, and any metal back box should also be correctly bonded where required. Effective earthing is essential for fault protection. The electrician must test earth continuity and confirm that the circuit's protective device will disconnect within the required time under fault conditions.
Its use depends on the installation zone, enclosure protection and local regulations. Because no specific IP rating is provided in the product data, the BL237 should not be assumed to be weatherproof or suitable for direct exposure to water, dust, humidity or outdoor conditions. Wet areas, balconies, gardens and construction sites generally require appropriately rated enclosures, suitable RCD protection and accessories selected for the environmental conditions.
It may be used as a replacement when the wall box, fixing arrangement, wiring condition, circuit rating and applicable standard are compatible. Before replacement, an electrician should inspect the conductors for heat damage, loose terminations, inadequate earth continuity or insufficient box depth. The circuit must be tested after installation rather than treating the work as a simple faceplate change.
Double-pole switching isolates both live and neutral at the socket, offering a clear local means of disconnecting connected equipment. This is beneficial for everyday appliance control and maintenance in homes, offices, shops and hospitality properties. It does not replace circuit isolation, however; electricians must still isolate and verify the supply before carrying out electrical work.
A standard indoor socket should not automatically be used as an exposed temporary site outlet. UAE construction sites can involve dust, moisture, impact and harsh handling, so temporary distribution systems normally require robust industrial accessories, suitable IP ratings, RCD protection and compliance with site safety procedures. The BL237 is better suited to completed indoor fixed installations unless it is housed in a properly designed and approved protective assembly.
Testing should form part of the complete circuit verification process and include protective conductor continuity, insulation resistance, polarity, earth-fault loop or equivalent protective measures, RCD or RCBO operation where fitted, and a functional check of the double-pole switch. Results should be recorded in the project's inspection and testing documentation in accordance with the consultant's requirements and relevant UAE regulations.
Switch off and isolate the circuit before inspection or cleaning. Wipe the faceplate with a soft, dry or slightly damp cloth and avoid solvents, abrasive cleaners and water entering the socket apertures. Replace the accessory if there are signs of cracking, discoloration, overheating, arcing, loose mounting or unreliable switching, and have the connected circuit inspected by a qualified electrician.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy