ABB Inora 1 Gang 13A Double Pole Switched Socket Outlet with Illumination White BL238
FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- The 13A rating suits appliance power loads.
- One-gang double pole switching controls supply.
- Safety shutters help guard live socket contacts.
- Illumination helps locate the socket at night.
- Polycarbonate parts support durable daily use.
- White finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
1 Gang Switched Socket Double Pole with Illumination from the ABB Inora wiring-accessory range.
Model
BL238 identifies the white finish variant.
Configuration
1 Gang Double Pole configuration is designed for switched appliance power connection.
Electrical Rating
13A at 250V AC supports the stated fixed-wiring application.
Indicator
Illuminated provides visible identification or easier location in low light.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Socket Safety
The Inora socket design uses safety shutters to help protect users from accidental access to live contacts.
Standard Compliance
BS 1363-2; SS 145-2; SASO 2203; MS 589-2 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit switched appliance power connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL238
Brands
ABB
Item Type
Single Socket
Number of Gang
1 Gang
Pole
2 Pole
Rated Current
13A
Rated Voltage
250V AC
Dimension
86 x 30.3 x 86 mm
Switch Type
Switched Socket
Height
86 mm
Width
30.3 mm
Depth
86 mm
Usage
Switched appliance power connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora BL238 13A DP single switched socket with neon?
The ABB Inora BL238 is a white 13A single switched socket outlet designed for supplying power to compatible appliances and equipment. Its double-pole switch isolates both the live and neutral conductors, while the integrated neon indicator provides a clear visual indication when the socket is switched on.
What does DP mean on the ABB Inora 13A socket?
DP means double pole. When operated, the socket switch controls both the live and neutral connections rather than switching only the live conductor. This provides more complete local isolation and is useful in residential, commercial and construction-related electrical installations where double-pole switching is specified.
What is the purpose of the neon indicator on the ABB BL238 socket?
The neon indicator illuminates when the socket is switched on, allowing users to check its operating status at a glance. This is particularly useful for fixed appliances, maintenance equipment, office devices and utility-area installations where clear power-status identification can improve convenience and operational safety.
Which plugs and appliances can be used with this 13A switched socket?
The socket is intended for compatible 13A rectangular-pin plugs commonly used in the UAE. It can serve suitable household, office and light commercial equipment, provided the connected appliance and circuit remain within the socket's 13A rating. High-load equipment should be checked against its nameplate current and the circuit design before connection.
Is the ABB Inora BL238 suitable for UAE electrical installations?
Its 13A switched format is relevant to UAE residential and commercial projects that use British-style socket systems. Before installation, the contractor should confirm compatibility with the approved project specification, applicable UAE electrical regulations and the requirements of the relevant local authority, such as DEWA, ADDC or the authority serving the project location.
Can the ABB Inora 13A socket be installed in villas, apartments and commercial buildings?
Yes, it is suitable for appropriately designed indoor electrical installations in villas, apartments, offices, retail units and similar buildings. Common applications include bedrooms, living areas, offices, meeting rooms and utility spaces. Final suitability depends on the circuit rating, mounting system, environmental conditions and approved electrical drawings.
How should the ABB Inora BL238 switched socket be installed?
Installation should be completed by a qualified electrician. The circuit must first be isolated and verified as dead. The electrician should use a compatible mounting box, identify the live, neutral and earth conductors, connect them to the correctly marked terminals, tighten all terminals to the manufacturer's requirements and secure the faceplate without trapping or damaging cables. The circuit should then be inspected and electrically tested before energisation.
What installation checks are required after fitting this 13A socket?
The electrician should check conductor termination, protective-earth continuity, polarity, insulation resistance and the operation of the double-pole switch and neon indicator. Applicable RCD or RCBO protection should also be tested where required by the circuit design and local regulations. Test results should be recorded as part of the project's inspection and commissioning documentation.
Can this socket be used in kitchens, bathrooms or outdoor locations?
The product data does not state an IP rating, so it should not be assumed to be weatherproof or suitable for direct exposure to water, dust or outdoor conditions. Use in kitchens, bathrooms, balconies, plant areas or external locations must comply with applicable electrical-zone and ingress-protection requirements. A suitably rated weatherproof enclosure or dedicated IP-rated socket should be selected where environmental protection is required.
What cable size should be used with the ABB Inora 13A DP socket?
Cable size cannot be selected from the socket rating alone. It must be determined by a qualified electrical designer or electrician based on the circuit arrangement, protective-device rating, installation method, cable length, voltage drop, ambient temperature, grouping and other derating factors relevant to UAE conditions. The cable must also fit the socket terminals correctly without damaging or removing conductor strands.
Can the ABB BL238 socket be connected to a ring or radial circuit?
It may be used on an appropriately designed ring or radial final circuit where permitted by the approved electrical design. The circuit configuration, cable capacity, protective device and number of connected outlets must comply with the project's specifications and applicable UAE authority requirements. Circuit modifications should not be made without proper load assessment and testing.
Why is double-pole switching useful in construction and building projects?
Double-pole switching provides local disconnection of both live and neutral conductors, which can support safer isolation and clearer equipment control. In construction projects, it is useful where specifications call for switched socket outlets serving appliances, office equipment or maintenance devices. It does not replace circuit isolation procedures, lockout practices or upstream protective devices during electrical work.
Is this ABB 13A socket suitable for high-power construction tools?
Only equipment whose operating current, starting current and plug configuration are compatible with the socket and its circuit should be connected. Heavy-duty construction tools, welders, large compressors and industrial machinery may require dedicated industrial sockets, higher-rated circuits or three-phase supplies. Contractors should verify each tool's electrical nameplate and the temporary-power design before use.
Does the neon indicator replace electrical testing before maintenance?
No. The neon indicator is only a convenient status display and must never be treated as proof that a circuit is safe to work on. Before maintenance, the circuit should be properly isolated, secured against reconnection and tested for absence of voltage using an approved test instrument and safe isolation procedure.
How should the ABB Inora white switched socket be maintained?
Keep the faceplate clean and dry, using a soft cloth without abrasive cleaners or excessive moisture. Periodically inspect it for discoloration, heat damage, cracks, loose mounting, buzzing, sparking or an unreliable switch. If any defect is found, stop using the outlet and arrange inspection by a qualified electrician; internal repairs should not be attempted by the user.
Frequently Asked Questions
The ABB Inora BL238 is a white 13A single switched socket outlet designed for supplying power to compatible appliances and equipment. Its double-pole switch isolates both the live and neutral conductors, while the integrated neon indicator provides a clear visual indication when the socket is switched on.
DP means double pole. When operated, the socket switch controls both the live and neutral connections rather than switching only the live conductor. This provides more complete local isolation and is useful in residential, commercial and construction-related electrical installations where double-pole switching is specified.
The neon indicator illuminates when the socket is switched on, allowing users to check its operating status at a glance. This is particularly useful for fixed appliances, maintenance equipment, office devices and utility-area installations where clear power-status identification can improve convenience and operational safety.
The socket is intended for compatible 13A rectangular-pin plugs commonly used in the UAE. It can serve suitable household, office and light commercial equipment, provided the connected appliance and circuit remain within the socket's 13A rating. High-load equipment should be checked against its nameplate current and the circuit design before connection.
Its 13A switched format is relevant to UAE residential and commercial projects that use British-style socket systems. Before installation, the contractor should confirm compatibility with the approved project specification, applicable UAE electrical regulations and the requirements of the relevant local authority, such as DEWA, ADDC or the authority serving the project location.
Yes, it is suitable for appropriately designed indoor electrical installations in villas, apartments, offices, retail units and similar buildings. Common applications include bedrooms, living areas, offices, meeting rooms and utility spaces. Final suitability depends on the circuit rating, mounting system, environmental conditions and approved electrical drawings.
Installation should be completed by a qualified electrician. The circuit must first be isolated and verified as dead. The electrician should use a compatible mounting box, identify the live, neutral and earth conductors, connect them to the correctly marked terminals, tighten all terminals to the manufacturer's requirements and secure the faceplate without trapping or damaging cables. The circuit should then be inspected and electrically tested before energisation.
The electrician should check conductor termination, protective-earth continuity, polarity, insulation resistance and the operation of the double-pole switch and neon indicator. Applicable RCD or RCBO protection should also be tested where required by the circuit design and local regulations. Test results should be recorded as part of the project's inspection and commissioning documentation.
The product data does not state an IP rating, so it should not be assumed to be weatherproof or suitable for direct exposure to water, dust or outdoor conditions. Use in kitchens, bathrooms, balconies, plant areas or external locations must comply with applicable electrical-zone and ingress-protection requirements. A suitably rated weatherproof enclosure or dedicated IP-rated socket should be selected where environmental protection is required.
Cable size cannot be selected from the socket rating alone. It must be determined by a qualified electrical designer or electrician based on the circuit arrangement, protective-device rating, installation method, cable length, voltage drop, ambient temperature, grouping and other derating factors relevant to UAE conditions. The cable must also fit the socket terminals correctly without damaging or removing conductor strands.
It may be used on an appropriately designed ring or radial final circuit where permitted by the approved electrical design. The circuit configuration, cable capacity, protective device and number of connected outlets must comply with the project's specifications and applicable UAE authority requirements. Circuit modifications should not be made without proper load assessment and testing.
Double-pole switching provides local disconnection of both live and neutral conductors, which can support safer isolation and clearer equipment control. In construction projects, it is useful where specifications call for switched socket outlets serving appliances, office equipment or maintenance devices. It does not replace circuit isolation procedures, lockout practices or upstream protective devices during electrical work.
Only equipment whose operating current, starting current and plug configuration are compatible with the socket and its circuit should be connected. Heavy-duty construction tools, welders, large compressors and industrial machinery may require dedicated industrial sockets, higher-rated circuits or three-phase supplies. Contractors should verify each tool's electrical nameplate and the temporary-power design before use.
No. The neon indicator is only a convenient status display and must never be treated as proof that a circuit is safe to work on. Before maintenance, the circuit should be properly isolated, secured against reconnection and tested for absence of voltage using an approved test instrument and safe isolation procedure.
Keep the faceplate clean and dry, using a soft cloth without abrasive cleaners or excessive moisture. Periodically inspect it for discoloration, heat damage, cracks, loose mounting, buzzing, sparking or an unreliable switch. If any defect is found, stop using the outlet and arrange inspection by a qualified electrician; internal repairs should not be attempted by the user.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy