ABB

ABB Inora 1 Gang 13A Switched Fused Connection Unit Royal Gold BL508-PG

In Stock
33.71
EXCL.VAT
Incl. 5% VAT AED 35.40

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • The 13A fuse protects a fixed appliance feed.
    • A local switch controls the fused appliance feed.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • BS fused-unit standards support safe installation.
    • Royal Gold finish suits coordinated interiors.

Features & Benefits

Product Type

13A Switched Fused Connection Unit from the ABB Inora wiring-accessory range.

Model

BL508-PG identifies the royal gold finish variant.

Configuration

1 Gang configuration is designed for switched fused fixed-appliance connection.

Electrical Rating

13A at 250V AC supports the stated fixed-wiring application.

Installation

Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 1363-4; SS 403 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in Royal Gold suit switched fused fixed-appliance connection in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

Royal Gold

Quantity Unit

PCS

Model No

BL508-PG

Brands

ABB

Item Type

Fused Connection Unit

Number of Gang

1 Gang

Rated Current

13A

Rated Voltage

250V AC

Switch Type

Switched

Usage

Switched fused fixed-appliance connection

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL508-PG is a 13A switched fused connection unit designed to provide local switching and fuse protection for a permanently connected electrical appliance or circuit. It combines an accessible fuse carrier and an on/off switch in a decorative royal gold finish, making it suitable for residential, commercial and hospitality interiors.

A 13A switched fused connection unit, commonly called a switched FCU or fused spur, is used to connect fixed electrical equipment to a final circuit while providing local isolation and replaceable fuse protection. Typical applications may include water heaters, extractor fans, kitchen appliances, ventilation equipment and other compatible fixed loads. The connected appliance rating and manufacturer instructions must be checked before installation.

It is intended for applications compatible with a 13A fused connection unit and the UAE's nominal 230V, 50Hz low-voltage supply. Product approval, circuit design and installation must comply with applicable UAE regulations, project specifications and the requirements of the relevant local authority, such as DEWA, ADDC or SEWA. An authorised electrician should confirm suitability for the intended load.

Yes, the BL508-PG can be specified for residential villas, apartments, offices, hotels, retail spaces and other construction or refurbishment projects where a switched fused connection point is required. Before procurement, the electrical engineer or contractor should confirm the model, finish, back-box compatibility, load requirements and compliance documentation against the approved material submittal and project specification.

Installation should be completed with the circuit isolated, locked out where required and verified dead using suitable test equipment. The electrician should fit the unit to a compatible electrical back box, terminate the supply and load conductors at the correctly marked terminals, connect the protective earth, tighten terminals to the manufacturer's specified torque and install the correct fuse. Continuity, insulation resistance, polarity and functional tests should be completed before energising the circuit.

The fuse rating must protect the appliance cable and match the connected equipment manufacturer's instructions; it should not automatically be assumed that every appliance requires a 13A fuse. Depending on the load, a lower-rated compatible fuse may be necessary. The circuit must not exceed the FCU's 13A rating, and fuse selection should be made by a qualified electrician.

It may be used only when the equipment's running current, starting characteristics, cable size and manufacturer instructions are compatible with a 13A fused connection unit. Many air conditioners and higher-power water heaters require a dedicated circuit and a suitably rated isolator rather than a standard 13A FCU. A UAE-licensed electrical contractor should calculate the load and select the correct protective and isolation device.

The decorative royal gold finish suits visible indoor locations, including kitchens and premium interior spaces. Installation in bathrooms, wet zones, dusty construction areas or outdoors requires an enclosure and ingress-protection rating appropriate to the location, along with compliance with applicable wiring-zone and local authority requirements. Do not assume the standard indoor faceplate is weatherproof unless the ABB technical documentation specifically confirms an IP rating.

Contractors should verify model number BL508-PG, 13A rating, switched configuration, royal gold finish, mounting-box requirements, terminal capacity, required fuse, indoor or environmental suitability and coordination with the selected ABB Inora wiring-accessory range. Project teams should also check the consultant-approved brand list, material submittal, authority requirements and appliance connection schedule.

Keep the faceplate clean with a soft, dry or lightly damp cloth and avoid abrasive cleaners that could damage the royal gold finish. If the fuse operates repeatedly, do not keep replacing it without investigation; isolate the circuit and have an electrician inspect the appliance, wiring and load. Signs such as heat discolouration, a loose switch, buzzing or a burning smell require immediate isolation and professional assessment.

A standard socket accepts a removable plug, while a fused connection unit is generally used for a fixed or flex-connected appliance. The BL508-PG provides local switching and fuse protection without relying on a plug-and-socket connection. The appropriate accessory depends on the appliance instructions, circuit design, accessibility requirements and approved electrical drawings.

The BL508-PG combines the practical functions of local switching and fused appliance protection with a royal gold appearance suited to coordinated luxury interiors. It is relevant to UAE villa, hospitality, office and residential fit-out projects where visible wiring accessories need to complement gold-toned décor. For a consistent result, confirm finish compatibility with other ABB Inora switches and sockets used on the project.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy