ABB

ABB Inora 1 Gang 13A Switched Fused Connection Unit Starry Black BL508-885

In Stock
33.71
EXCL.VAT
Incl. 5% VAT AED 35.40

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • The 13A fuse protects a fixed appliance feed.
    • A local switch controls the fused appliance feed.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • BS fused-unit standards support safe installation.
    • Starry Black finish suits coordinated interiors.

Features & Benefits

Product Type

13A Switched Fused Connection Unit from the ABB Inora wiring-accessory range.

Model

BL508-885 identifies the starry black finish variant.

Configuration

1 Gang configuration is designed for switched fused fixed-appliance connection.

Electrical Rating

13A at 250V AC supports the stated fixed-wiring application.

Installation

Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 1363-4; SS 403 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in Starry Black suit switched fused fixed-appliance connection in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

Starry Black

Quantity Unit

PCS

Model No

BL508-885

Brands

ABB

Item Type

Fused Connection Unit

Number of Gang

1 Gang

Rated Current

13A

Rated Voltage

250V AC

Switch Type

Switched

Usage

Switched fused fixed-appliance connection

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL508-885 is a 13A switched fused connection unit designed to provide local switching and fuse protection for fixed electrical appliances and equipment. Part of the ABB Inora range, it combines a functional connection point with a contemporary Starry Black finish suitable for residential, commercial and hospitality interiors.

A 13A switched fused connection unit, commonly called a switched FCU or fused spur, is used to connect fixed electrical equipment to a final circuit while providing local isolation and cartridge-fuse protection. Typical applications include water heaters, extractor fans, kitchen hoods, pumps, signage, control equipment and selected air-conditioning accessories, subject to the appliance load and electrical design.

The BL508-885 is identified as a switched fused connection unit with a 13A rating and a Starry Black decorative finish. Its switch allows the connected load to be controlled locally, while the fuse protects the appliance connection and downstream cable. Confirm terminal capacity, mounting-box requirements, fuse specification and dimensional details from the current ABB technical datasheet before installation.

No. The fuse in an FCU primarily protects the connected appliance, flexible cable or spur downstream of the unit. It does not replace the distribution-board circuit breaker, residual-current protection or other protective devices required by the electrical design. The complete circuit must be coordinated for cable size, load, fault current, earthing and disconnection time.

Installation should be completed by a qualified electrician. The supply must first be isolated, locked off where applicable and proven dead. The incoming supply conductors and outgoing load conductors should then be connected to the correctly marked line, neutral and earth terminals in accordance with the ABB wiring diagram. Conductors must be properly stripped, securely terminated and arranged without damaging insulation. Fit the unit into a compatible mounting box, install the correctly rated fuse and test polarity, earth continuity, insulation resistance and functional switching before energising.

It may be used as a fused spur where permitted by the circuit design and applicable wiring regulations. The electrician must verify the existing circuit type, protective-device rating, cable size, connected load and number of spurs. It should not be added to an overloaded circuit or used to bypass required dedicated-circuit provisions for high-load equipment.

It can be considered only when the equipment's normal current, starting current and manufacturer instructions are compatible with a 13A fused connection. Many large water heaters and air-conditioning systems require higher-rated double-pole isolators or dedicated circuits and should not be connected through a standard 13A FCU. A qualified electrical engineer or electrician should check the equipment nameplate and approved project drawings.

Yes, its 13A fused format is relevant to many UAE residential, commercial, hotel and fit-out projects that use British-style wiring accessories. Final selection and installation must comply with the latest requirements of the relevant UAE authority, such as DEWA, ADDC or the applicable local utility, together with project specifications and recognised standards. Product approvals and conformity documentation should be confirmed when required for consultant or authority submission.

For British-style fused connection units, BS 1363-4 is commonly referenced, while the replaceable cartridge fuse is generally associated with BS 1362. UAE projects must also follow the current local electrical installation regulations, authority requirements and approved material schedules. Buyers should verify the exact certification of model BL508-885 from ABB documentation rather than assuming approval solely from its rating.

The unit is generally intended for appropriate indoor locations. In kitchens, it should be positioned away from excessive heat, steam, water and areas exposed to cleaning chemicals. Bathroom and outdoor installations require strict compliance with electrical zones, ingress-protection requirements and local regulations; a suitably IP-rated accessory or enclosure may be necessary. Do not install this decorative FCU where direct water, dust or weather exposure exceeds its documented rating.

The fuse must be selected to protect the connected appliance and its cable and must not exceed the FCU's 13A rating. A lower-rated fuse may be required for low-power equipment, depending on the appliance manufacturer's instructions and conductor capacity. Use only a correctly certified cartridge fuse of the specified type, and never replace it with wire, foil or an oversized fuse.

Use a mounting box compatible with the accessory format, fixing centres and required installation depth. Sufficient depth is important to accommodate terminals and conductors without tight bends, trapped insulation or pressure on the faceplate. Confirm the exact box dimensions and minimum depth in the latest ABB Inora product datasheet, particularly for conduit installations and projects using larger or multiple conductors.

Yes. The Starry Black finish is well suited to modern villas, apartments, offices, hotels, retail spaces and other interiors featuring dark wiring accessories or contemporary design schemes. For a coordinated result, match it with compatible ABB Inora switches and sockets, and confirm the finish against project samples because appearance can vary under different lighting conditions.

Confirm the model number BL508-885, 13A rating, Starry Black finish, required quantity and compatibility with the project's mounting boxes and other ABB Inora accessories. Also verify the connected appliance load, indoor or environmental conditions, required approvals, fuse requirements and whether a switched FCU is specified instead of an unswitched unit, isolator or dedicated connection point.

Keep the faceplate dry and clean it with a soft cloth without abrasive or solvent-based chemicals. If the fuse repeatedly operates, the switch becomes hot, discoloration appears or there is a burning smell, isolate the circuit and have it inspected by a qualified electrician. Do not repeatedly replace a blown fuse until the appliance, cable and terminations have been checked for overloads, loose connections or faults.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy