    Key Features

    • The 13A fuse protects a fixed appliance feed.
    • A local switch controls the fused appliance feed.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • BS fused-unit standards support safe installation.
    • White finish suits coordinated interiors.

Features & Benefits

Product Type

13A Switched Fused Connection Unit from the ABB Inora wiring-accessory range.

Model

BL508 identifies the white finish variant.

Configuration

1 Gang configuration is designed for switched fused fixed-appliance connection.

Electrical Rating

13A at 250V AC supports the stated fixed-wiring application.

Installation

Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 1363-4; SS 403 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in White suit switched fused fixed-appliance connection in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

White

Quantity Unit

PCS

Model No

BL508

Brands

ABB

Item Type

Fused Connection Unit

Number of Gang

1 Gang

Rated Current

13A

Rated Voltage

250V AC

Switch Type

Switched

Usage

Switched fused fixed-appliance connection

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL508 is a 13A switched fused connection unit, commonly called an FCU or fused spur. It provides local switching and fuse protection for a fixed electrical appliance or a spur connected to a suitable final circuit. Its white finish is suitable for residential, commercial and light construction interiors.

A 13A switched fused connection unit is used to supply and isolate fixed electrical equipment while protecting the outgoing cable or appliance with a replaceable fuse. Typical applications may include water heaters, extractor fans, kitchen appliances, pumps, signage and other fixed loads, subject to the equipment rating, circuit design and manufacturer instructions.

The BL508 is identified as a 13A switched fused connection unit. The connected load, cable size, fuse rating, circuit protective device and installation method must all be coordinated by a qualified electrician. For exact voltage, terminal capacity, pole configuration, dimensions and compliance markings, check the product label and current ABB technical datasheet before specification.

Yes. This model combines a manual switch with a fuse carrier in one connection unit. The switch provides convenient local control or isolation, while the correctly selected fuse protects the connected equipment or outgoing conductor against excessive current. It does not replace the distribution board circuit breaker or other protection required by the electrical design.

Use only a compatible fuse of the type specified on the unit or in the ABB documentation, commonly a BS 1362 cartridge fuse for this class of accessory. The fuse must be selected according to the appliance load and cable capacity and must not exceed 13A. A lower-rated fuse may be required for low-power appliances, fans, controls or smaller outgoing cables.

Installation should be completed with the circuit safely isolated and proven dead. The electrician should confirm the supply and load terminals, connect line, neutral and protective earth conductors as marked, tighten terminals to the specified torque, fit the correctly rated fuse and secure the accessory to a compatible mounting box. Polarity, earthing, continuity, insulation resistance and functional operation should be tested before energising.

A fused connection unit is commonly used to create a protected spur from a correctly designed ring final circuit. However, connection location, conductor size, maximum demand, existing spurs and protective-device coordination must be checked by a competent electrician. The completed work should comply with the approved project design and applicable UAE electrical requirements.

The 13A fused connection unit format is widely relevant to UAE villas, apartments, offices, retail units and other projects using British-style wiring accessories. Acceptance depends on the project specification, authority requirements and product certification. Contractors should verify the current ABB compliance documentation and follow the relevant electricity authority regulations, such as DEWA or the applicable local utility, together with recognised wiring standards.

It may be used for suitable fixed appliances when installed in a permitted location. Kitchens, bathrooms and utility rooms can involve moisture, heat and restricted electrical zones, so the mounting position and enclosure protection must be assessed carefully. Do not assume the standard white unit is weatherproof or splashproof unless an appropriate IP rating is confirmed; use a suitable rated enclosure where required.

It should not be installed directly outdoors unless ABB confirms an appropriate ingress-protection rating for the unit and the complete installation. For gardens, balconies, plant areas or exposed construction locations, mount it inside a suitable weather-resistant enclosure and provide any additional RCD protection, cable glands and environmental protection required by the electrical design.

No RCD or earth-leakage function is indicated in the supplied product information. A switched fused connection unit provides local switching and fuse-based overcurrent protection. Where RCD protection is required, it must be provided separately through a suitable distribution-board device or another approved protective arrangement.

Before installation, verify the accessory dimensions, mounting centres, required box depth, cable entry space and compatibility with the selected flush or surface box. Also confirm conductor sizes, terminal capacity, earthing arrangements and the connected appliance load. Avoid forcing conductors behind the plate, as trapped cables or loose terminals can cause overheating and unreliable operation.

It may be suitable only when the appliance operating current does not exceed the unit rating and the appliance manufacturer permits fused-connection-unit control. Many water heaters and air-conditioning systems require higher-rated double-pole isolators, dedicated circuits or specific isolation arrangements. The equipment nameplate, installation manual and approved electrical drawings must be checked before selection.

A qualified electrician should inspect conductor termination, protective-earth continuity, polarity, insulation resistance and circuit protective-device coordination. The switch and connected appliance should then be functionally tested, and terminals should show no signs of looseness or abnormal heating. Testing and documentation should follow the project specification and applicable UAE authority requirements.

Keep the faceplate clean and dry and inspect it periodically for discoloration, cracking, looseness, buzzing, burning smells or excessive heat. If the fuse operates repeatedly, do not fit a higher-rated fuse; isolate the circuit and have the appliance, cable and connections investigated by a qualified electrician. Replace damaged accessories rather than attempting temporary repairs.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy