ABB

ABB Inora 1 Gang 13A Switched Fused Connection Unit with Illumination Starry Black BL507-885

In Stock
34.49
EXCL.VAT
Incl. 5% VAT AED 36.21

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • The 13A fuse protects a fixed appliance feed.
    • A local switch controls the fused appliance feed.
    • A 35 mm flush box supports concealed fitting.
    • Illumination helps locate the control at night.
    • BS fused-unit standards support safe installation.
    • Starry Black finish suits coordinated interiors.

Features & Benefits

Product Type

13A Switched Fused Connection Unit with Illumination from the ABB Inora wiring-accessory range.

Model

BL507-885 identifies the starry black finish variant.

Configuration

1 Gang configuration is designed for switched fused fixed-appliance connection.

Electrical Rating

13A at 250V AC supports the stated fixed-wiring application.

Indicator

Illuminated provides visible identification or easier location in low light.

Installation

Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Standard Compliance

BS 1363-4; SS 403 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in Starry Black suit switched fused fixed-appliance connection in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

Starry Black

Quantity Unit

PCS

Model No

BL507-885

Brands

ABB

Item Type

Fused Connection Unit

Number of Gang

1 Gang

Rated Current

13A

Rated Voltage

250V AC

Switch Type

Switched

Usage

Switched fused fixed-appliance connection

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL507-885 is a 13A switched fused connection unit, commonly called a switched fused spur or FCU. It provides local switching, fuse protection and an LED indication point for a fixed electrical appliance or load. Its Starry Black finish is suitable for contemporary residential, commercial and hospitality interiors.

A 13A switched fused connection unit is used to connect and locally isolate fixed electrical equipment while protecting the outgoing load with a replaceable fuse. Typical applications may include water heaters, extractor fans, kitchen appliances, pumps, signage, control equipment and other compatible fixed loads. The appliance rating, cable size, circuit protection and manufacturer instructions must be checked before use.

The integrated LED provides a visible status indication. Its exact operation can depend on the product terminal arrangement and installation method, so the wiring diagram supplied with the unit should be followed. The LED is useful where users or maintenance teams need a quick visual indication of the connected circuit's status.

It can be considered for compatible UAE residential, commercial and construction projects where a 13A fused connection unit is specified. Installers must verify the unit's marked voltage, frequency, approvals and installation requirements against the project specification and the regulations of the relevant UAE authority, such as DEWA, ADDC, SEWA or the applicable local utility. Installation should also follow current UAE electrical and fire-safety requirements.

Only when the connected equipment's rated current, starting current and isolation requirements are within the FCU's specifications and the appliance manufacturer permits this connection method. Many air conditioners and higher-power water heaters require a dedicated circuit and a higher-rated double-pole isolator rather than a 13A fused connection unit. A qualified electrician should calculate the load before installation.

The incoming supply and outgoing load conductors must be connected to the correctly identified line, neutral and earth terminals in accordance with the ABB wiring diagram. Isolate and verify the circuit is dead before work begins, use a compatible mounting box, maintain correct conductor polarity, terminate the protective earth, tighten terminals to the specified torque and fit the appropriate fuse. The circuit should then be tested before energisation. Installation must be completed by a qualified electrician.

Use only the fuse type and maximum rating specified by ABB for the BL507-885. A 13A fuse is not automatically correct for every appliance; a lower fuse rating may be required to protect the connected equipment and flexible cable. The electrician should select the fuse according to the appliance rating, cable capacity and manufacturer instructions, using an approved fuse compliant with the applicable standard.

No. The fuse inside the FCU provides local downstream protection for the connected load, while the distribution-board circuit breaker protects the fixed circuit wiring against overcurrent. Required RCD or RCBO protection must also be provided separately where specified. The FCU, breaker, cable and connected appliance should be coordinated as one electrical protection system.

Contractors should confirm the 13A rating, marked operating voltage and frequency, terminal capacity, fuse specification, switching arrangement, mounting-box compatibility, ingress-protection requirements and relevant product certifications. They should also verify that the Starry Black finish matches the approved material schedule and that the unit satisfies consultant, MEP and local authority requirements.

Do not install it directly outdoors, in bathrooms or in other damp, dusty or exposed locations unless ABB documentation confirms a suitable ingress-protection rating and the installation complies with the required electrical zones. For exposed UAE environments, use an appropriately rated weatherproof enclosure or select a dedicated outdoor FCU designed for heat, dust and moisture conditions.

Use the mounting box format and minimum depth specified in the ABB product documentation, allowing sufficient space for conductors without sharp bends or compression. Cable type and cross-sectional area must be selected according to the circuit design, connected load, installation method, ambient temperature, voltage drop and protective device. Terminal capacity should be verified before procurement and installation.

Periodically inspect the faceplate, switch, LED, fuse carrier and surrounding wall for looseness, cracking, discolouration or overheating. If the fuse repeatedly operates, do not install a higher-rated fuse; isolate the supply and investigate the appliance, wiring and load. Any internal inspection, fuse replacement beyond routine user access or terminal tightening should be undertaken safely by a competent electrician.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy