- The 13A fuse protects a fixed appliance feed.
- Unswitched output suits permanent connections.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- BS fused-unit standards support safe installation.
- Royal Gold finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
13A Unswitched Fused Connection Unit from the ABB Inora wiring-accessory range.
Model
BL506-PG identifies the royal gold finish variant.
Configuration
1 Gang configuration is designed for fused fixed-appliance connection.
Electrical Rating
13A at 250V AC supports the stated fixed-wiring application.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 1363-4; SS 403 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in Royal Gold suit fused fixed-appliance connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
Royal Gold
Quantity Unit
PCS
Model No
BL506-PG
Brands
ABB
Item Type
Fused Connection Unit
Number of Gang
1 Gang
Rated Current
13A
Rated Voltage
250V AC
Switch Type
Unswitched
Usage
Fused fixed-appliance connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 13A Unswitched Fused Connection Unit Royal Gold BL506-PG?
The ABB Inora BL506-PG is a 13A unswitched fused connection unit designed to provide a protected connection between a fixed electrical circuit and compatible equipment. It incorporates fuse protection but does not have an on/off rocker switch. Its Royal Gold finish makes it suitable for residential, hospitality and premium commercial interiors where electrical accessories must coordinate with the surrounding décor.
What is an unswitched fused connection unit used for?
An unswitched fused connection unit, commonly called an unswitched FCU or fused spur, is used to connect fixed or permanently wired appliances while providing local overcurrent protection through a replaceable fuse. Typical applications may include water heaters, ventilation equipment, access-control systems, signage and selected kitchen or building-services equipment, subject to the appliance load, manufacturer instructions and approved electrical design.
What is the electrical rating of the ABB Inora BL506-PG fused connection unit?
The BL506-PG is rated at 13A. The connected load must remain within the unit's rating, the circuit design limits and the appliance manufacturer's requirements. The fitted fuse should be correctly selected for the appliance and cable rather than automatically using the maximum fuse rating. A qualified electrician should confirm voltage compatibility, conductor size, protective device coordination and earthing before installation.
What does 'unswitched' mean on the ABB Inora 13A fused spur?
Unswitched means the connection unit has no local rocker switch for manually turning the connected equipment on or off. The appliance remains supplied whenever the upstream circuit is energised, subject to the fuse and other protective devices. If local functional switching or isolation is required, the electrician should specify a suitable switched FCU or separate isolator based on the equipment and applicable regulations.
Can the ABB Inora BL506-PG be used for construction and MEP projects in the UAE?
Yes, it can be considered for residential, commercial, hospitality and fit-out MEP projects where a 13A unswitched fused connection is specified. The project consultant or contractor should verify the product submittal against the approved drawings, load schedule, equipment requirements and the regulations of the relevant UAE authority, such as DEWA or the applicable local electricity and building authority.
How is the ABB Inora 13A unswitched fused connection unit installed?
Installation should be completed by a licensed electrician. The circuit must first be isolated, locked out where required and tested to confirm it is dead. The electrician should use a compatible wall box, terminate line, neutral and earth conductors at the correctly identified terminals, tighten connections to the manufacturer's specified torque, fit the appropriate fuse, secure the faceplate without overtightening and carry out continuity, insulation, polarity, earthing and functional tests before energising.
Can the ABB Inora BL506-PG be connected as a fused spur from a ring or radial circuit?
It may be used as a fused spur where the circuit arrangement and local regulations permit. Whether it is supplied from a ring final circuit, radial circuit or dedicated circuit depends on the electrical design, connected load, cable size and upstream protection. The installer must follow the approved project drawings and applicable UAE wiring requirements rather than selecting the circuit arrangement solely from the FCU's 13A rating.
Which fuse should be used with the ABB Inora 13A fused connection unit?
Use only a fuse type and rating approved for the unit and suitable for the connected appliance. In British-style fused connection units, a compliant cartridge fuse such as a BS 1362 type is commonly specified, but this should be confirmed from ABB documentation and project requirements. The fuse rating must protect the appliance flex and equipment; fitting a higher-rated fuse than required can reduce protection.
Is the ABB Inora Royal Gold fused connection unit suitable for kitchens and utility areas?
It can be used indoors in kitchens, utility rooms and similar areas when installed in an appropriate location and used with compatible equipment. It should not be exposed directly to water, excessive condensation, grease, heat or harsh cleaning chemicals unless its verified enclosure protection and installation method permit such conditions. UAE project specifications may require additional protection or a suitably rated accessory near sinks and wet zones.
Can this 13A fused connection unit be used for an electric water heater or air-conditioning equipment?
Suitability depends on the equipment's rated current, starting current, isolation requirements and manufacturer instructions. Some small water heaters or controls may be compatible with a 13A FCU, while larger heaters and air-conditioning equipment usually require a dedicated circuit and appropriately rated double-pole isolator. An MEP engineer or licensed electrician should verify the load before selecting this product.
Does the ABB Inora BL506-PG provide electrical isolation?
The fuse can be removed after the upstream supply has been safely isolated, but an unswitched FCU should not automatically be treated as the required local isolating device. Where maintenance isolation is necessary, the electrical design may require a switched double-pole FCU or a separate isolator with the correct rating and contact arrangement. Follow the connected equipment instructions and relevant UAE authority requirements.
What wall box is required for the ABB Inora BL506-PG?
Use a compatible flush or surface-mounted box that matches the accessory format and provides sufficient depth for the terminals, cable bend radius and conductor arrangement. Box dimensions and minimum depth should be checked against the current ABB Inora technical datasheet before procurement. On construction projects, coordinate box installation with blockwork, drywall, tiling and final finished-wall levels so the faceplate sits securely and evenly.
How should the Royal Gold finish be protected and cleaned on site?
Keep the faceplate covered during painting, plastering, grouting and other dusty construction work. Clean it with a soft, dry or lightly damp microfibre cloth after isolating the circuit. Avoid abrasive pads, solvent-based cleaners, acidic chemicals and strong detergents because they may damage or discolour the decorative finish. The protective packaging should preferably remain in place until final fixing.
What checks are required after installing the ABB Inora 13A FCU?
The electrician should verify terminal tightness, protective-conductor continuity, insulation resistance, polarity, earth-fault protection and coordination with the upstream protective device. The correct fuse rating and appliance operation should also be confirmed. For UAE construction projects, test results should be recorded in the relevant inspection and testing documentation and submitted for consultant or authority approval when required.
Why choose the ABB Inora BL506-PG Royal Gold fused connection unit for UAE interiors?
The ABB Inora BL506-PG combines a functional 13A fused connection point with a decorative Royal Gold appearance. It is particularly relevant to UAE villas, apartments, hotels, offices and retail fit-outs where coordinated premium finishes are specified. Buyers should match it with compatible ABB Inora accessories and confirm technical compliance, environmental suitability and consultant approval before bulk ordering.
Frequently Asked Questions
The ABB Inora BL506-PG is a 13A unswitched fused connection unit designed to provide a protected connection between a fixed electrical circuit and compatible equipment. It incorporates fuse protection but does not have an on/off rocker switch. Its Royal Gold finish makes it suitable for residential, hospitality and premium commercial interiors where electrical accessories must coordinate with the surrounding décor.
An unswitched fused connection unit, commonly called an unswitched FCU or fused spur, is used to connect fixed or permanently wired appliances while providing local overcurrent protection through a replaceable fuse. Typical applications may include water heaters, ventilation equipment, access-control systems, signage and selected kitchen or building-services equipment, subject to the appliance load, manufacturer instructions and approved electrical design.
The BL506-PG is rated at 13A. The connected load must remain within the unit's rating, the circuit design limits and the appliance manufacturer's requirements. The fitted fuse should be correctly selected for the appliance and cable rather than automatically using the maximum fuse rating. A qualified electrician should confirm voltage compatibility, conductor size, protective device coordination and earthing before installation.
Unswitched means the connection unit has no local rocker switch for manually turning the connected equipment on or off. The appliance remains supplied whenever the upstream circuit is energised, subject to the fuse and other protective devices. If local functional switching or isolation is required, the electrician should specify a suitable switched FCU or separate isolator based on the equipment and applicable regulations.
Yes, it can be considered for residential, commercial, hospitality and fit-out MEP projects where a 13A unswitched fused connection is specified. The project consultant or contractor should verify the product submittal against the approved drawings, load schedule, equipment requirements and the regulations of the relevant UAE authority, such as DEWA or the applicable local electricity and building authority.
Installation should be completed by a licensed electrician. The circuit must first be isolated, locked out where required and tested to confirm it is dead. The electrician should use a compatible wall box, terminate line, neutral and earth conductors at the correctly identified terminals, tighten connections to the manufacturer's specified torque, fit the appropriate fuse, secure the faceplate without overtightening and carry out continuity, insulation, polarity, earthing and functional tests before energising.
It may be used as a fused spur where the circuit arrangement and local regulations permit. Whether it is supplied from a ring final circuit, radial circuit or dedicated circuit depends on the electrical design, connected load, cable size and upstream protection. The installer must follow the approved project drawings and applicable UAE wiring requirements rather than selecting the circuit arrangement solely from the FCU's 13A rating.
Use only a fuse type and rating approved for the unit and suitable for the connected appliance. In British-style fused connection units, a compliant cartridge fuse such as a BS 1362 type is commonly specified, but this should be confirmed from ABB documentation and project requirements. The fuse rating must protect the appliance flex and equipment; fitting a higher-rated fuse than required can reduce protection.
It can be used indoors in kitchens, utility rooms and similar areas when installed in an appropriate location and used with compatible equipment. It should not be exposed directly to water, excessive condensation, grease, heat or harsh cleaning chemicals unless its verified enclosure protection and installation method permit such conditions. UAE project specifications may require additional protection or a suitably rated accessory near sinks and wet zones.
Suitability depends on the equipment's rated current, starting current, isolation requirements and manufacturer instructions. Some small water heaters or controls may be compatible with a 13A FCU, while larger heaters and air-conditioning equipment usually require a dedicated circuit and appropriately rated double-pole isolator. An MEP engineer or licensed electrician should verify the load before selecting this product.
The fuse can be removed after the upstream supply has been safely isolated, but an unswitched FCU should not automatically be treated as the required local isolating device. Where maintenance isolation is necessary, the electrical design may require a switched double-pole FCU or a separate isolator with the correct rating and contact arrangement. Follow the connected equipment instructions and relevant UAE authority requirements.
Use a compatible flush or surface-mounted box that matches the accessory format and provides sufficient depth for the terminals, cable bend radius and conductor arrangement. Box dimensions and minimum depth should be checked against the current ABB Inora technical datasheet before procurement. On construction projects, coordinate box installation with blockwork, drywall, tiling and final finished-wall levels so the faceplate sits securely and evenly.
Keep the faceplate covered during painting, plastering, grouting and other dusty construction work. Clean it with a soft, dry or lightly damp microfibre cloth after isolating the circuit. Avoid abrasive pads, solvent-based cleaners, acidic chemicals and strong detergents because they may damage or discolour the decorative finish. The protective packaging should preferably remain in place until final fixing.
The electrician should verify terminal tightness, protective-conductor continuity, insulation resistance, polarity, earth-fault protection and coordination with the upstream protective device. The correct fuse rating and appliance operation should also be confirmed. For UAE construction projects, test results should be recorded in the relevant inspection and testing documentation and submitted for consultant or authority approval when required.
The ABB Inora BL506-PG combines a functional 13A fused connection point with a decorative Royal Gold appearance. It is particularly relevant to UAE villas, apartments, hotels, offices and retail fit-outs where coordinated premium finishes are specified. Buyers should match it with compatible ABB Inora accessories and confirm technical compliance, environmental suitability and consultant approval before bulk ordering.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy