    Key Features

    • The 15A rating suits appliance power loads.
    • One-gang single pole switching controls supply.
    • Safety shutters help guard live socket contacts.
    • A 35 mm flush box supports concealed fitting.
    • Polycarbonate parts support durable daily use.
    • White finish suits coordinated interiors.

Features & Benefits

Product Type

1 Gang Switched Socket Single Pole from the ABB Inora wiring-accessory range.

Model

BL209 identifies the white finish variant.

Configuration

1 Gang Single Pole configuration is designed for switched appliance power connection.

Electrical Rating

15A at 250V AC supports the stated fixed-wiring application.

Installation

Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.

Materials

ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.

Socket Safety

The Inora socket design uses safety shutters to help protect users from accidental access to live contacts.

Standard Compliance

BS 546; SS 472; MS 1577 are listed in the ABB Inora technical information for the applicable product function.

Design & Application

Clean lines and gently curved Inora forms in White suit switched appliance power connection in residential and commercial interiors.

Key Specifications

Custom Stock Status

In Stock

Color

White

Quantity Unit

PCS

Model No

BL209

Brands

ABB

Item Type

Single Socket

Number of Gang

1 Gang

Pole

1 Pole

Rated Current

15A

Rated Voltage

250V AC

Dimension

86 x 36.2 x 86 mm

Switch Type

Switched Socket

Height

86 mm

Width

36.2 mm

Depth

86 mm

Usage

Switched appliance power connection

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Inora BL209 is a single 15A switched electrical socket from the Inora range, finished in white for clean integration with residential, commercial and construction interiors. Its SP designation means the switch uses single-pole operation, allowing the connected load to be controlled locally from the socket. Buyers should confirm the plug-pin configuration, voltage marking and installation requirements against the project specification before ordering.

SP means single pole. When the socket switch is turned off, it isolates one conductor—normally the live conductor—while the neutral remains connected. Correct live, neutral and earth wiring is therefore essential, and installation should be completed and tested by a qualified electrician in accordance with UAE electrical regulations and the relevant authority requirements.

The BL209 is intended for compatible electrical equipment with a current demand within the socket's 15A rating. It may be specified for dedicated appliances or equipment in homes, offices, workshops, retail spaces and construction projects. The appliance plug type, actual running current, starting current and circuit design must all be checked; a 15A rating does not mean every high-load appliance can be connected without an appropriately sized circuit and protective device.

It can be used in UAE projects where a 15A single switched socket is included in the approved electrical specification. UAE installations generally operate on a nominal 230V, 50Hz supply, but compatibility must be confirmed from the product marking and project documents. The consultant or electrical contractor should also verify acceptance under the applicable UAE authority rules, such as DEWA, ADDC, SEWA or the relevant local authority, together with the project's specified BS or IEC requirements.

First isolate and lock out the circuit supply, then verify that it is de-energised with an approved tester. Install a compatible wall box of suitable depth, terminate the live, neutral and protective-earth conductors at the correctly marked terminals, secure the socket without trapping or damaging cables, and align the faceplate. After installation, a qualified electrician should perform continuity, polarity, insulation-resistance and protective-device tests before energising the circuit.

Cable size and protective-device rating cannot be selected from the socket rating alone. They depend on the connected load, circuit arrangement, cable material, installation method, ambient temperature, grouping, route length and permissible voltage drop. UAE ambient conditions and concealed conduit runs can require derating. A qualified electrical engineer or contractor should calculate the circuit and coordinate the MCB or RCBO so that both the cable and socket are adequately protected.

The socket should be installed only in a back box that matches its mounting dimensions, screw centres and required wiring depth. Before first-fix or fit-out work, compare the BL209 datasheet or physical sample with the specified flush or surface box. Sufficient depth should be provided for safe conductor bending and terminal clearance, particularly when rigid cables, conduit entries or multiple conductors are used.

Do not assume that the standard BL209 faceplate is weatherproof. For balconies, gardens, wash areas, outdoor kitchens, plant rooms or dusty construction environments, install it only within a suitably rated weatherproof enclosure and where permitted by the applicable wiring-zone rules. The required IP rating, RCD or RCBO protection, earthing arrangement and enclosure material should be selected through a project-specific risk assessment.

Not automatically. UAE buildings commonly use socket outlets based on BS 1363 for standard 13A fused plugs, while some projects specify 15A outlets for particular applications. Differences may include plug-pin geometry, current rating, circuit protection, wall-box compatibility and project approval. Confirm that the connected appliance has the matching plug and never force a plug into an incompatible outlet or use an unapproved adaptor.

A switched socket provides convenient local control of connected equipment without repeatedly removing the plug. This can support safer isolation during routine use and may reduce unnecessary standby operation. In fit-out projects, it also gives occupants a clear control point, although the socket switch is not a substitute for circuit isolation, lockout procedures or a dedicated isolator where one is required.

The electrician should confirm secure terminations, correct polarity, protective-conductor continuity, insulation resistance and satisfactory operation of the switch. The circuit protective device and RCD or RCBO operation should be tested where applicable. The faceplate should sit level without gaps, cracks or exposed conductors, and the socket identification should correspond with the distribution-board schedule and approved electrical drawings.

Switch off and safely isolate the circuit before inspection or maintenance. Clean the white faceplate with a soft, dry or lightly damp cloth; do not use solvents, abrasive cleaners or excessive water. Arrange inspection by a qualified electrician if the socket becomes loose, discoloured, unusually warm, cracked, noisy or produces a burning smell, and replace damaged components rather than continuing to use them.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy