FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- The 15A rating suits appliance power loads.
- One-gang single pole switching controls supply.
- Safety shutters help guard live socket contacts.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- White finish suits coordinated interiors.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
1 Gang Switched Socket Single Pole from the ABB Inora wiring-accessory range.
Model
BL209 identifies the white finish variant.
Configuration
1 Gang Single Pole configuration is designed for switched appliance power connection.
Electrical Rating
15A at 250V AC supports the stated fixed-wiring application.
Installation
Designed for flush installation with a 35 mm back box and a 86 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Socket Safety
The Inora socket design uses safety shutters to help protect users from accidental access to live contacts.
Standard Compliance
BS 546; SS 472; MS 1577 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit switched appliance power connection in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL209
Brands
ABB
Item Type
Single Socket
Number of Gang
1 Gang
Pole
1 Pole
Rated Current
15A
Rated Voltage
250V AC
Dimension
86 x 36.2 x 86 mm
Switch Type
Switched Socket
Height
86 mm
Width
36.2 mm
Depth
86 mm
Usage
Switched appliance power connection
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 15A SP Single Switched Socket White BL209?
The ABB Inora BL209 is a single 15A switched electrical socket from the Inora range, finished in white for clean integration with residential, commercial and construction interiors. Its SP designation means the switch uses single-pole operation, allowing the connected load to be controlled locally from the socket. Buyers should confirm the plug-pin configuration, voltage marking and installation requirements against the project specification before ordering.
What does SP mean on the ABB Inora BL209 socket?
SP means single pole. When the socket switch is turned off, it isolates one conductor—normally the live conductor—while the neutral remains connected. Correct live, neutral and earth wiring is therefore essential, and installation should be completed and tested by a qualified electrician in accordance with UAE electrical regulations and the relevant authority requirements.
Which appliances and electrical loads can use this 15A switched socket?
The BL209 is intended for compatible electrical equipment with a current demand within the socket's 15A rating. It may be specified for dedicated appliances or equipment in homes, offices, workshops, retail spaces and construction projects. The appliance plug type, actual running current, starting current and circuit design must all be checked; a 15A rating does not mean every high-load appliance can be connected without an appropriately sized circuit and protective device.
Is the ABB Inora 15A socket suitable for UAE construction projects?
It can be used in UAE projects where a 15A single switched socket is included in the approved electrical specification. UAE installations generally operate on a nominal 230V, 50Hz supply, but compatibility must be confirmed from the product marking and project documents. The consultant or electrical contractor should also verify acceptance under the applicable UAE authority rules, such as DEWA, ADDC, SEWA or the relevant local authority, together with the project's specified BS or IEC requirements.
How is the ABB Inora BL209 switched socket installed?
First isolate and lock out the circuit supply, then verify that it is de-energised with an approved tester. Install a compatible wall box of suitable depth, terminate the live, neutral and protective-earth conductors at the correctly marked terminals, secure the socket without trapping or damaging cables, and align the faceplate. After installation, a qualified electrician should perform continuity, polarity, insulation-resistance and protective-device tests before energising the circuit.
What cable size and circuit protection should be used with this 15A socket?
Cable size and protective-device rating cannot be selected from the socket rating alone. They depend on the connected load, circuit arrangement, cable material, installation method, ambient temperature, grouping, route length and permissible voltage drop. UAE ambient conditions and concealed conduit runs can require derating. A qualified electrical engineer or contractor should calculate the circuit and coordinate the MCB or RCBO so that both the cable and socket are adequately protected.
Can the ABB Inora BL209 be fitted into a standard wall box?
The socket should be installed only in a back box that matches its mounting dimensions, screw centres and required wiring depth. Before first-fix or fit-out work, compare the BL209 datasheet or physical sample with the specified flush or surface box. Sufficient depth should be provided for safe conductor bending and terminal clearance, particularly when rigid cables, conduit entries or multiple conductors are used.
Can this ABB 15A switched socket be installed outdoors or in wet areas?
Do not assume that the standard BL209 faceplate is weatherproof. For balconies, gardens, wash areas, outdoor kitchens, plant rooms or dusty construction environments, install it only within a suitably rated weatherproof enclosure and where permitted by the applicable wiring-zone rules. The required IP rating, RCD or RCBO protection, earthing arrangement and enclosure material should be selected through a project-specific risk assessment.
Is this 15A socket interchangeable with a UAE 13A socket outlet?
Not automatically. UAE buildings commonly use socket outlets based on BS 1363 for standard 13A fused plugs, while some projects specify 15A outlets for particular applications. Differences may include plug-pin geometry, current rating, circuit protection, wall-box compatibility and project approval. Confirm that the connected appliance has the matching plug and never force a plug into an incompatible outlet or use an unapproved adaptor.
Why choose a switched socket for a residential or commercial fit-out?
A switched socket provides convenient local control of connected equipment without repeatedly removing the plug. This can support safer isolation during routine use and may reduce unnecessary standby operation. In fit-out projects, it also gives occupants a clear control point, although the socket switch is not a substitute for circuit isolation, lockout procedures or a dedicated isolator where one is required.
What checks should be completed before handing over the installed socket?
The electrician should confirm secure terminations, correct polarity, protective-conductor continuity, insulation resistance and satisfactory operation of the switch. The circuit protective device and RCD or RCBO operation should be tested where applicable. The faceplate should sit level without gaps, cracks or exposed conductors, and the socket identification should correspond with the distribution-board schedule and approved electrical drawings.
How should the ABB Inora white switched socket be cleaned and maintained?
Switch off and safely isolate the circuit before inspection or maintenance. Clean the white faceplate with a soft, dry or lightly damp cloth; do not use solvents, abrasive cleaners or excessive water. Arrange inspection by a qualified electrician if the socket becomes loose, discoloured, unusually warm, cracked, noisy or produces a burning smell, and replace damaged components rather than continuing to use them.
Frequently Asked Questions
The ABB Inora BL209 is a single 15A switched electrical socket from the Inora range, finished in white for clean integration with residential, commercial and construction interiors. Its SP designation means the switch uses single-pole operation, allowing the connected load to be controlled locally from the socket. Buyers should confirm the plug-pin configuration, voltage marking and installation requirements against the project specification before ordering.
SP means single pole. When the socket switch is turned off, it isolates one conductor—normally the live conductor—while the neutral remains connected. Correct live, neutral and earth wiring is therefore essential, and installation should be completed and tested by a qualified electrician in accordance with UAE electrical regulations and the relevant authority requirements.
The BL209 is intended for compatible electrical equipment with a current demand within the socket's 15A rating. It may be specified for dedicated appliances or equipment in homes, offices, workshops, retail spaces and construction projects. The appliance plug type, actual running current, starting current and circuit design must all be checked; a 15A rating does not mean every high-load appliance can be connected without an appropriately sized circuit and protective device.
It can be used in UAE projects where a 15A single switched socket is included in the approved electrical specification. UAE installations generally operate on a nominal 230V, 50Hz supply, but compatibility must be confirmed from the product marking and project documents. The consultant or electrical contractor should also verify acceptance under the applicable UAE authority rules, such as DEWA, ADDC, SEWA or the relevant local authority, together with the project's specified BS or IEC requirements.
First isolate and lock out the circuit supply, then verify that it is de-energised with an approved tester. Install a compatible wall box of suitable depth, terminate the live, neutral and protective-earth conductors at the correctly marked terminals, secure the socket without trapping or damaging cables, and align the faceplate. After installation, a qualified electrician should perform continuity, polarity, insulation-resistance and protective-device tests before energising the circuit.
Cable size and protective-device rating cannot be selected from the socket rating alone. They depend on the connected load, circuit arrangement, cable material, installation method, ambient temperature, grouping, route length and permissible voltage drop. UAE ambient conditions and concealed conduit runs can require derating. A qualified electrical engineer or contractor should calculate the circuit and coordinate the MCB or RCBO so that both the cable and socket are adequately protected.
The socket should be installed only in a back box that matches its mounting dimensions, screw centres and required wiring depth. Before first-fix or fit-out work, compare the BL209 datasheet or physical sample with the specified flush or surface box. Sufficient depth should be provided for safe conductor bending and terminal clearance, particularly when rigid cables, conduit entries or multiple conductors are used.
Do not assume that the standard BL209 faceplate is weatherproof. For balconies, gardens, wash areas, outdoor kitchens, plant rooms or dusty construction environments, install it only within a suitably rated weatherproof enclosure and where permitted by the applicable wiring-zone rules. The required IP rating, RCD or RCBO protection, earthing arrangement and enclosure material should be selected through a project-specific risk assessment.
Not automatically. UAE buildings commonly use socket outlets based on BS 1363 for standard 13A fused plugs, while some projects specify 15A outlets for particular applications. Differences may include plug-pin geometry, current rating, circuit protection, wall-box compatibility and project approval. Confirm that the connected appliance has the matching plug and never force a plug into an incompatible outlet or use an unapproved adaptor.
A switched socket provides convenient local control of connected equipment without repeatedly removing the plug. This can support safer isolation during routine use and may reduce unnecessary standby operation. In fit-out projects, it also gives occupants a clear control point, although the socket switch is not a substitute for circuit isolation, lockout procedures or a dedicated isolator where one is required.
The electrician should confirm secure terminations, correct polarity, protective-conductor continuity, insulation resistance and satisfactory operation of the switch. The circuit protective device and RCD or RCBO operation should be tested where applicable. The faceplate should sit level without gaps, cracks or exposed conductors, and the socket identification should correspond with the distribution-board schedule and approved electrical drawings.
Switch off and safely isolate the circuit before inspection or maintenance. Clean the white faceplate with a soft, dry or lightly damp cloth; do not use solvents, abrasive cleaners or excessive water. Arrange inspection by a qualified electrician if the socket becomes loose, discoloured, unusually warm, cracked, noisy or produces a burning smell, and replace damaged components rather than continuing to use them.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy