- RJ45 Cat 6 supports structured network links.
- Two-gang layout suits organized cabling.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- The clean faceplate suits modern interiors.
- White finish supports coordinated wall fittings.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
2 Gang RJ45 Cat 6 Data Outlet from the ABB Inora wiring-accessory range.
Model
BL329 identifies the white finish variant.
Configuration
2 Gang configuration is designed for ethernet network connections.
Connector Type
RJ45 Cat 6 provides the stated communication or signal interface.
Installation
Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 5733 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit ethernet network connections in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL329
Brands
ABB
Item Type
Data Socket
Number of Gang
2 Gang
Connector Type
RJ45 Cat 6
Dimension
86 x 38.8 x 86 mm
Height
86 mm
Width
38.8 mm
Depth
86 mm
Usage
Ethernet Network Connections
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora 2 Gang CAT.6 Data Socket White BL329?
The ABB Inora BL329 is a white, two-gang CAT.6 data socket designed to provide two structured network connection points in one wall outlet. It is suitable for Ethernet cabling in UAE homes, offices, shops, hotels, schools and commercial buildings. The socket forms part of a permanent data-cabling installation and should be used with compatible CAT.6 cable, connectors and network equipment.
What is the advantage of using a 2 gang CAT.6 data socket?
A two-gang data socket provides two network outlets at one location, allowing devices such as computers, IP telephones, smart TVs, printers, wireless access points or other network equipment to be connected separately. This supports cleaner cable management and reduces the need for loose network splitters or long patch leads in residential and commercial interiors.
What network performance can the ABB Inora BL329 CAT.6 socket support?
When installed as part of a correctly designed CAT.6 channel, the socket can support Gigabit Ethernet applications and CAT.6 frequencies up to 250 MHz. Actual speed depends on the complete channel, including the cable, patch panel, patch cords, termination quality, route length and active network equipment. A standard compliant copper Ethernet channel is generally limited to a maximum total length of 100 metres, including patch cords.
Where can the ABB Inora 2 Gang CAT.6 Data Socket be used?
The BL329 is suitable for indoor data outlets in villas, apartments, offices, meeting rooms, retail units, schools, clinics, hotels and other UAE construction projects. Typical applications include workstations, smart TVs, routers, IP phones, network printers, CCTV network points and Wi-Fi access points. It should not be installed outdoors or in wet, dusty or exposed areas unless placed inside a suitably rated enclosure.
How is the ABB Inora BL329 CAT.6 data socket installed?
Installation typically involves mounting the socket on a compatible wall box, routing the CAT.6 cable without excessive pulling or bending, preparing the cable jacket, terminating each conductor according to the socket markings, securing the mechanism and fitting the faceplate. Both ends of each cable must follow the same T568A or T568B wiring scheme. A qualified structured-cabling technician should complete and test the installation.
Should T568A or T568B wiring be used with this CAT.6 socket?
Either T568A or T568B may be used if the termination markings and project specification permit it, but the same scheme must be maintained at both ends of the cable. T568B is common in many commercial installations, while project consultants may specify a particular standard. Consistency is essential to avoid crossed pairs, connection faults and reduced network performance.
What cable should be used with the ABB Inora 2 Gang CAT.6 socket?
Use genuine solid-conductor CAT.6 installation cable suitable for the project environment and compatible with the socket termination. The cable construction, conductor size, shielding type and fire-performance classification should match the consultant's specification and applicable UAE authority requirements. For concealed building installations, select an approved cable with the required flame-retardant or low-smoke, zero-halogen properties where specified.
Can the ABB Inora BL329 be used with CAT.5e cable?
A physical connection may be possible where the conductor and termination specifications are compatible, but the completed link will perform only to the rating of its lowest-category component. To achieve a properly specified CAT.6 installation, use CAT.6 cable, CAT.6 patch panels and suitable CAT.6 patch cords throughout the channel.
Does the ABB Inora CAT.6 socket require an electrical power connection?
No separate mains power connection is required because this is a passive data outlet. It carries network signals between connected equipment and the patch panel or network cabinet. If Power over Ethernet is used, compatible network equipment supplies low-voltage power through the Ethernet cabling; the entire channel and connected devices must be suitable for the selected PoE application.
Can the BL329 data socket be installed beside an electrical power socket?
It may be installed in the same general area, but data and mains wiring must be segregated according to the project drawings, applicable UAE regulations and good installation practice. Avoid running Ethernet cable parallel and too close to power cables, particularly high-load circuits, because electromagnetic interference can affect data performance. Use separate containment or approved partitioned trunking and maintain the required separation.
What construction-stage precautions are required when installing this data socket?
Coordinate the outlet position and mounting-box depth before plastering, tiling or installing joinery. Protect the CAT.6 cable from crushing, sharp bends, moisture, paint and construction debris. Keep sufficient cable length for proper termination, but do not leave tightly coiled excess cable inside the box. The final faceplate should be fitted only after dusty work is complete, and each port should be clearly labelled to match the patch-panel schedule.
How should CAT.6 cable be terminated to maintain performance?
Keep the twisted pairs intact as close as possible to the termination point, remove only the necessary amount of outer jacket and do not nick or flatten the conductors. Follow the colour code printed on the termination module and use the recommended termination tool where required. Excessive untwisting, tight bends or poor conductor seating can increase crosstalk and prevent the link from meeting CAT.6 performance.
How should the installed ABB Inora CAT.6 data outlets be tested?
Each outlet should first be checked for correct wire map, continuity, open circuits, short circuits, reversals and split pairs. For projects requiring certified CAT.6 performance, use a calibrated field cable certifier to test parameters such as insertion loss, return loss, propagation delay and near-end crosstalk. Test results should be labelled and included in the handover documentation for commercial and construction projects.
Is the ABB Inora BL329 suitable for UAE residential and commercial projects?
Yes, it is relevant to UAE structured-cabling applications where a neat, white, two-port CAT.6 wall outlet is required. Product selection and installation should follow the approved project specification, local authority requirements and recognised structured-cabling practices such as ISO/IEC 11801 or ANSI/TIA-568.2-D. For regulated developments, contractors should also confirm consultant, developer and authority approvals before procurement.
How do I maintain and troubleshoot the ABB Inora 2 Gang CAT.6 Data Socket?
Keep the outlet dry and free from dust, and clean the faceplate using a soft dry or slightly damp cloth without solvents. If a network connection fails, test with a known working patch cord and device, inspect the port for damage and verify the corresponding patch-panel connection. Persistent faults should be checked with a cable tester by a qualified technician rather than repeatedly re-terminating the socket without diagnosis.
Frequently Asked Questions
The ABB Inora BL329 is a white, two-gang CAT.6 data socket designed to provide two structured network connection points in one wall outlet. It is suitable for Ethernet cabling in UAE homes, offices, shops, hotels, schools and commercial buildings. The socket forms part of a permanent data-cabling installation and should be used with compatible CAT.6 cable, connectors and network equipment.
A two-gang data socket provides two network outlets at one location, allowing devices such as computers, IP telephones, smart TVs, printers, wireless access points or other network equipment to be connected separately. This supports cleaner cable management and reduces the need for loose network splitters or long patch leads in residential and commercial interiors.
When installed as part of a correctly designed CAT.6 channel, the socket can support Gigabit Ethernet applications and CAT.6 frequencies up to 250 MHz. Actual speed depends on the complete channel, including the cable, patch panel, patch cords, termination quality, route length and active network equipment. A standard compliant copper Ethernet channel is generally limited to a maximum total length of 100 metres, including patch cords.
The BL329 is suitable for indoor data outlets in villas, apartments, offices, meeting rooms, retail units, schools, clinics, hotels and other UAE construction projects. Typical applications include workstations, smart TVs, routers, IP phones, network printers, CCTV network points and Wi-Fi access points. It should not be installed outdoors or in wet, dusty or exposed areas unless placed inside a suitably rated enclosure.
Installation typically involves mounting the socket on a compatible wall box, routing the CAT.6 cable without excessive pulling or bending, preparing the cable jacket, terminating each conductor according to the socket markings, securing the mechanism and fitting the faceplate. Both ends of each cable must follow the same T568A or T568B wiring scheme. A qualified structured-cabling technician should complete and test the installation.
Either T568A or T568B may be used if the termination markings and project specification permit it, but the same scheme must be maintained at both ends of the cable. T568B is common in many commercial installations, while project consultants may specify a particular standard. Consistency is essential to avoid crossed pairs, connection faults and reduced network performance.
Use genuine solid-conductor CAT.6 installation cable suitable for the project environment and compatible with the socket termination. The cable construction, conductor size, shielding type and fire-performance classification should match the consultant's specification and applicable UAE authority requirements. For concealed building installations, select an approved cable with the required flame-retardant or low-smoke, zero-halogen properties where specified.
A physical connection may be possible where the conductor and termination specifications are compatible, but the completed link will perform only to the rating of its lowest-category component. To achieve a properly specified CAT.6 installation, use CAT.6 cable, CAT.6 patch panels and suitable CAT.6 patch cords throughout the channel.
No separate mains power connection is required because this is a passive data outlet. It carries network signals between connected equipment and the patch panel or network cabinet. If Power over Ethernet is used, compatible network equipment supplies low-voltage power through the Ethernet cabling; the entire channel and connected devices must be suitable for the selected PoE application.
It may be installed in the same general area, but data and mains wiring must be segregated according to the project drawings, applicable UAE regulations and good installation practice. Avoid running Ethernet cable parallel and too close to power cables, particularly high-load circuits, because electromagnetic interference can affect data performance. Use separate containment or approved partitioned trunking and maintain the required separation.
Coordinate the outlet position and mounting-box depth before plastering, tiling or installing joinery. Protect the CAT.6 cable from crushing, sharp bends, moisture, paint and construction debris. Keep sufficient cable length for proper termination, but do not leave tightly coiled excess cable inside the box. The final faceplate should be fitted only after dusty work is complete, and each port should be clearly labelled to match the patch-panel schedule.
Keep the twisted pairs intact as close as possible to the termination point, remove only the necessary amount of outer jacket and do not nick or flatten the conductors. Follow the colour code printed on the termination module and use the recommended termination tool where required. Excessive untwisting, tight bends or poor conductor seating can increase crosstalk and prevent the link from meeting CAT.6 performance.
Each outlet should first be checked for correct wire map, continuity, open circuits, short circuits, reversals and split pairs. For projects requiring certified CAT.6 performance, use a calibrated field cable certifier to test parameters such as insertion loss, return loss, propagation delay and near-end crosstalk. Test results should be labelled and included in the handover documentation for commercial and construction projects.
Yes, it is relevant to UAE structured-cabling applications where a neat, white, two-port CAT.6 wall outlet is required. Product selection and installation should follow the approved project specification, local authority requirements and recognised structured-cabling practices such as ISO/IEC 11801 or ANSI/TIA-568.2-D. For regulated developments, contractors should also confirm consultant, developer and authority approvals before procurement.
Keep the outlet dry and free from dust, and clean the faceplate using a soft dry or slightly damp cloth without solvents. If a network connection fails, test with a known working patch cord and device, inspect the port for damage and verify the corresponding patch-panel connection. Persistent faults should be checked with a cable tester by a qualified technician rather than repeatedly re-terminating the socket without diagnosis.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy