FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- TV and RJ45 Cat 5E support signal and data links.
- Two-gang layout suits organized cabling.
- A 35 mm flush box supports concealed fitting.
- Polycarbonate parts support durable daily use.
- The clean faceplate suits modern interiors.
- White finish supports coordinated wall fittings.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
2 Gang TV and RJ45 Cat 5E Data Outlet from the ABB Inora wiring-accessory range.
Model
BL325 identifies the white finish variant.
Configuration
2 Gang configuration is designed for tv and ethernet connections.
Signal / Load Rating
5-1000 MHz is specified for the intended connected equipment.
Connector Type
TV coaxial and RJ45 Cat 5E provides the stated communication or signal interface.
Installation
Designed for flush installation with a 35 mm back box and a 146 x 86 mm faceplate.
Materials
ABB specifies high-quality polycarbonate for surface and installation parts with red copper and silver-alloy metal components to support durable electrical performance.
Standard Compliance
BS 5733 are listed in the ABB Inora technical information for the applicable product function.
Design & Application
Clean lines and gently curved Inora forms in White suit tv and ethernet connections in residential and commercial interiors.
Key Specifications
Custom Stock Status
In Stock
Color
White
Quantity Unit
PCS
Model No
BL325
Brands
ABB
Item Type
Data Socket
Number of Gang
2 Gang
Frequency
5-1000 MHz
Connector Type
TV coaxial and RJ45 Cat 5E
Dimension
86 x 38.8 x 86 mm
Height
86 mm
Width
38.8 mm
Depth
86 mm
Usage
TV and Ethernet Connections
Installation Type
Flush Mounted
Frequently Asked Questions
What is the ABB Inora BL325 2 Gang TV and Data Outlet?
The ABB Inora BL325 is a white, wall-mounted 2 gang outlet designed to provide TV and wired data connection points in one location. It combines a TV outlet rated for a 5–1000 MHz frequency range with an RJ45 Category 5e data outlet, making it suitable for residential, commercial, hospitality and mixed-use construction projects.
What connections are supported by the ABB Inora BL325 outlet?
This outlet supports a coaxial TV service operating within 5–1000 MHz and an RJ45 Cat.5e connection for Ethernet or compatible structured cabling applications. The exact rear termination method and compatible faceplate or mounting accessories should be confirmed against the ABB Inora BL325 technical documentation before installation.
What does the 5–1000 MHz rating mean?
The 5–1000 MHz specification indicates the supported frequency range of the TV outlet path. This range is commonly used for terrestrial television, cable television and other compatible RF distribution systems. Final reception quality depends on the building's antenna or TV distribution system, cable type, splitter losses, signal level and correct termination.
What network performance can the RJ45 Cat.5e outlet provide?
When installed as part of a correctly designed Cat.5e channel, the RJ45 outlet can support common Ethernet applications, including Gigabit Ethernet up to 1000 Mbps over a channel length of up to 100 metres. Actual performance depends on the cable category, patch leads, termination quality, network equipment, route length and compliance of the complete cabling channel.
Is the ABB Inora 2 Gang TV and Data Outlet suitable for UAE buildings?
Yes, it is suitable for indoor TV and structured data installations in UAE villas, apartments, offices, hotels and commercial developments, provided it matches the approved project specification. Installation should comply with applicable UAE electrical and telecommunications requirements, local authority rules, consultant drawings and the relevant service provider's cabling guidelines.
Where is this combined TV and RJ45 outlet commonly installed?
The ABB Inora BL325 is commonly installed behind televisions, in living rooms, bedrooms, hotel rooms, meeting rooms, reception areas and office workspaces. Combining TV and data services at one wall position helps create a cleaner finish and supports smart televisions, IPTV equipment, desktop computers, media players and other compatible network devices.
How should the ABB Inora BL325 outlet be installed?
Mount the outlet in a compatible wall box and complete the coaxial and Cat.5e terminations according to ABB instructions and the approved wiring layout. Maintain the specified cable bend radius, avoid crushing or sharply bending cables, preserve pair twists close to the RJ45 termination and ensure the coaxial shield is properly prepared. Both links should be tested before the outlet is secured and handed over.
Can the TV coaxial cable and data cable share the same conduit?
Cable routing should follow the approved project design and applicable UAE requirements. TV coaxial and data cables may be routed within an ELV system where permitted, but they should be kept appropriately separated from mains power cables to reduce interference and maintain safety. Use dedicated containment, partitions or the separation distances specified by the consultant, authority or cabling standard.
Which cables should be used with the ABB Inora BL325?
Use a compliant Cat.5e cable for the RJ45 data connection and a suitable 75-ohm coaxial cable for the TV connection. Cable fire rating, shielding, jacket type and containment method should be selected according to the building type, indoor installation conditions, UAE fire and life-safety requirements, and the project's approved material schedule.
Does this outlet provide Wi-Fi or an internet connection by itself?
No. The RJ45 outlet is a passive termination point and does not generate Wi-Fi or internet service. It must be connected through structured cabling to a router, network switch or patch panel. The TV connection must similarly be connected to a compatible antenna, MATV, SMATV or cable TV distribution system.
How should contractors test the outlet after installation?
The Cat.5e link should be tested for wire map, continuity, pair faults and, where required, certified channel or permanent-link performance. The TV connection should be checked for continuity, correct shielding, signal level and signal quality across the required frequency range. Test results should be recorded where project handover documentation or consultant approval requires them.
What construction-stage precautions are recommended for this TV and data outlet?
Install the outlet only after the wall box is secure and wet trades are substantially complete. Protect the mechanism from paint, plaster, cement dust and moisture, and prevent excessive cable tension inside the box. Confirm mounting depth, wall finish thickness and cable entry positions before final fixing to avoid damaged terminations or an uneven faceplate.
Can the Cat.5e outlet be terminated using either T568A or T568B wiring?
Either T568A or T568B may be used if supported by the outlet's termination layout, but the same scheme must be applied consistently at both ends of the cable. Contractors should follow the project's structured cabling specification, labelling schedule and patch-panel configuration to prevent crossed pairs and network faults.
Is the ABB Inora BL325 intended for indoor or outdoor installation?
This type of wall outlet is generally intended for dry indoor locations. It should not be exposed directly to rain, washdown water, condensation, high dust levels or outdoor UAE weather unless installed within a suitably rated enclosure approved for those conditions. Check the product's declared environmental and ingress-protection ratings before use in demanding areas.
How can reliable long-term performance be maintained?
Keep the outlet clean and dry, avoid pulling connected leads sideways, and use good-quality Cat.5e patch cords and 75-ohm TV leads. If network speed drops or TV reception becomes unstable, inspect the patch cables, rear terminations, coaxial connectors, distribution equipment and signal source. Any damaged mechanism should be replaced rather than repaired with unapproved components.
Frequently Asked Questions
The ABB Inora BL325 is a white, wall-mounted 2 gang outlet designed to provide TV and wired data connection points in one location. It combines a TV outlet rated for a 5–1000 MHz frequency range with an RJ45 Category 5e data outlet, making it suitable for residential, commercial, hospitality and mixed-use construction projects.
This outlet supports a coaxial TV service operating within 5–1000 MHz and an RJ45 Cat.5e connection for Ethernet or compatible structured cabling applications. The exact rear termination method and compatible faceplate or mounting accessories should be confirmed against the ABB Inora BL325 technical documentation before installation.
The 5–1000 MHz specification indicates the supported frequency range of the TV outlet path. This range is commonly used for terrestrial television, cable television and other compatible RF distribution systems. Final reception quality depends on the building's antenna or TV distribution system, cable type, splitter losses, signal level and correct termination.
When installed as part of a correctly designed Cat.5e channel, the RJ45 outlet can support common Ethernet applications, including Gigabit Ethernet up to 1000 Mbps over a channel length of up to 100 metres. Actual performance depends on the cable category, patch leads, termination quality, network equipment, route length and compliance of the complete cabling channel.
Yes, it is suitable for indoor TV and structured data installations in UAE villas, apartments, offices, hotels and commercial developments, provided it matches the approved project specification. Installation should comply with applicable UAE electrical and telecommunications requirements, local authority rules, consultant drawings and the relevant service provider's cabling guidelines.
The ABB Inora BL325 is commonly installed behind televisions, in living rooms, bedrooms, hotel rooms, meeting rooms, reception areas and office workspaces. Combining TV and data services at one wall position helps create a cleaner finish and supports smart televisions, IPTV equipment, desktop computers, media players and other compatible network devices.
Mount the outlet in a compatible wall box and complete the coaxial and Cat.5e terminations according to ABB instructions and the approved wiring layout. Maintain the specified cable bend radius, avoid crushing or sharply bending cables, preserve pair twists close to the RJ45 termination and ensure the coaxial shield is properly prepared. Both links should be tested before the outlet is secured and handed over.
Cable routing should follow the approved project design and applicable UAE requirements. TV coaxial and data cables may be routed within an ELV system where permitted, but they should be kept appropriately separated from mains power cables to reduce interference and maintain safety. Use dedicated containment, partitions or the separation distances specified by the consultant, authority or cabling standard.
Use a compliant Cat.5e cable for the RJ45 data connection and a suitable 75-ohm coaxial cable for the TV connection. Cable fire rating, shielding, jacket type and containment method should be selected according to the building type, indoor installation conditions, UAE fire and life-safety requirements, and the project's approved material schedule.
No. The RJ45 outlet is a passive termination point and does not generate Wi-Fi or internet service. It must be connected through structured cabling to a router, network switch or patch panel. The TV connection must similarly be connected to a compatible antenna, MATV, SMATV or cable TV distribution system.
The Cat.5e link should be tested for wire map, continuity, pair faults and, where required, certified channel or permanent-link performance. The TV connection should be checked for continuity, correct shielding, signal level and signal quality across the required frequency range. Test results should be recorded where project handover documentation or consultant approval requires them.
Install the outlet only after the wall box is secure and wet trades are substantially complete. Protect the mechanism from paint, plaster, cement dust and moisture, and prevent excessive cable tension inside the box. Confirm mounting depth, wall finish thickness and cable entry positions before final fixing to avoid damaged terminations or an uneven faceplate.
Either T568A or T568B may be used if supported by the outlet's termination layout, but the same scheme must be applied consistently at both ends of the cable. Contractors should follow the project's structured cabling specification, labelling schedule and patch-panel configuration to prevent crossed pairs and network faults.
This type of wall outlet is generally intended for dry indoor locations. It should not be exposed directly to rain, washdown water, condensation, high dust levels or outdoor UAE weather unless installed within a suitably rated enclosure approved for those conditions. Check the product's declared environmental and ingress-protection ratings before use in demanding areas.
Keep the outlet clean and dry, avoid pulling connected leads sideways, and use good-quality Cat.5e patch cords and 75-ohm TV leads. If network speed drops or TV reception becomes unstable, inspect the patch cables, rear terminations, coaxial connectors, distribution equipment and signal source. Any damaged mechanism should be replaced rather than repaired with unapproved components.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
