FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- The BM329 provides two CAT6 RJ45 data ports.
- CAT6 performance supports speeds up to 1 Gbps.
- It supports network frequencies up to 250 MHz.
- The metal-clad faceplate offers robust protection.
- Its two-gang layout allows dual network connections.
- It is suitable for structured Ethernet cabling.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
CAT 6 Network Performance
Designed for Category 6 structured cabling systems, the outlet supports reliable high-speed Ethernet connectivity for computers, IP phones, smart televisions, access points and other network devices. When installed as part of a compliant CAT 6 channel using correctly rated cable and hardware, it can support Gigabit Ethernet and frequencies up to 250 MHz.
RJ45 Data Connection
The standard RJ45 interface provides broad compatibility with common Ethernet patch leads and network equipment, making the outlet suitable for residential, commercial, retail and light-industrial data installations.
2-Gang Metal-Clad Format
The 2-gang metal-clad construction provides a robust wiring accessory format for areas where greater durability is required than conventional plastic faceplates. It is well suited to workshops, utility rooms, warehouses, plant areas and other demanding indoor environments.
Durable Metal Faceplate
The metal-clad faceplate offers enhanced resistance to everyday knocks, abrasion and impact, helping protect the data termination while maintaining a neat and professional appearance in exposed installation locations.
Structured Cabling Compatibility
Suitable for integration into CAT 6 structured cabling networks, the outlet helps create an organised fixed connection point between horizontal network cabling and user equipment. Overall link performance depends on using compatible CAT 6 cable, patch panels, patch cords and correct termination practices.
Professional Fixed Installation
The outlet is intended for permanent building-network installations and should be fitted and tested by a qualified low-voltage or data-cabling technician. Correct cable routing, bend radius, termination and separation from mains wiring are essential for dependable network performance.
ABB BM329 Model
Identified as ABB model BM329, this outlet provides a clearly specified option for matching project schedules, replacement requirements and ABB metal-clad wiring accessory installations.
Suitable for UAE Projects
The robust 2-gang format is suitable for data-network projects in UAE homes and commercial premises where compatible mounting arrangements are used. Installation should follow the project’s structured cabling specification, applicable UAE authority requirements and recognised CAT 6 installation and testing practices.
Key Specifications
Custom Stock Status
In Stock
Weight
0.24 kg
Quantity Unit
PCS
Model No
BM329
Brands
ABB
Item Type
Data Socket
Number of Gang
2 Gang
Connector Type
Dual RJ45
Height
82.5 mm
Width
82.5 mm
Depth
47.4 mm
Usage
Dual structured network data connection
Installation Type
Surface Mounted
Frequently Asked Questions
What is the ABB Metal Clad 2 Gang CAT.6 RJ45 Data Outlet BM329?
The ABB BM329 is a metal-clad, two-gang RJ45 data outlet designed for terminating Cat 6 structured network cabling. It provides a durable connection point for Ethernet networks in offices, workshops, warehouses, plant rooms, commercial buildings and residential utility areas. Its metal-clad construction is particularly suitable for locations where a more robust accessory is preferred over a standard plastic data outlet.
What applications is the ABB BM329 Cat 6 data outlet suitable for?
The outlet can be used for wired LAN connections serving computers, IP telephones, wireless access points, printers, network-enabled equipment, CCTV systems and building-management devices. It is suitable for new construction, fit-out, renovation and network-upgrade projects across UAE residential, commercial and light-industrial properties.
Does the ABB BM329 support Gigabit Ethernet?
A correctly installed Cat 6 permanent link can support Gigabit Ethernet at channel lengths of up to 100 metres, subject to the cable, patch panels, patch cords, connectors and installation quality meeting Cat 6 requirements. Higher network speeds may be possible over shorter distances under applicable cabling standards, but the complete channel must be designed, installed and tested for the intended application.
Why choose a metal-clad RJ45 data outlet for a construction project?
Metal-clad accessories provide a robust surface finish for areas exposed to frequent use or a higher risk of impact. They are commonly specified in workshops, warehouses, back-of-house spaces, service corridors and utility rooms. The metal enclosure does not, by itself, confirm that the data link is shielded; shielding depends on the RJ45 module, cable, termination method and earthing design.
How is the ABB Metal Clad 2 Gang Cat 6 RJ45 Outlet installed?
Installation should be completed by a qualified ELV or structured-cabling technician. Plan the outlet position, install the compatible mounting box or containment, route the Cat 6 cable without crushing or excessive bending, maintain the cable twists close to each termination, terminate all conductors using the specified T568A or T568B scheme, secure the module and faceplate, label each port and test the completed link. Follow ABB installation instructions and the project consultant's approved drawings and specifications.
Should T568A or T568B wiring be used with the ABB BM329 outlet?
Either T568A or T568B may be used when supported by the installed module and project specification. The same wiring scheme must be maintained at both ends of the link. T568B is common in many commercial installations, but contractors should follow the approved structured-cabling schedule and existing site convention to avoid crossed or incorrectly mapped connections.
What cable should be used with this ABB Cat 6 RJ45 data outlet?
Use genuine Cat 6 horizontal cable with conductor type, shielding classification and fire-performance rating suitable for the project. Solid-conductor cable is generally used for permanent building links, while stranded patch cords are used between the outlet and connected equipment. Cable and connector categories should match, and indoor, outdoor, LSZH or fire-rated cable must be selected according to the route, environment and UAE project requirements.
How should Cat 6 data cabling be routed near electrical cables?
Data cables should be segregated from mains power wiring to reduce electromagnetic interference and comply with the project's ELV requirements. Use dedicated containment or the specified separation distance, cross power cables at approximately 90 degrees where necessary, and avoid routing data cable beside high-load circuits, motors or variable-frequency drives. Applicable local authority requirements, consultant specifications and standards such as ISO/IEC 11801 and ANSI/TIA-568 should be followed.
Is the ABB BM329 suitable for surface-mounted installations?
Metal-clad outlets are commonly selected for surface-mounted installations using a compatible box, conduit or trunking arrangement. Compatibility depends on the selected mounting box, entry method, back-box depth and cable bend radius. Confirm the required ABB accessories and dimensions before ordering, especially where galvanised conduit or industrial trunking is specified.
Can the ABB BM329 be installed outdoors in the UAE?
The outlet should not be assumed to be weatherproof unless the complete assembly has a manufacturer-declared IP rating suitable for outdoor use. For exposed UAE locations, install it inside an appropriately rated weatherproof enclosure and protect the cable from heat, ultraviolet exposure, dust, moisture and water ingress. Outdoor cable should have a suitable sheath, and all penetrations must be correctly sealed.
Is this Cat 6 outlet appropriate for UAE construction and fit-out projects?
Yes, the ABB BM329 is relevant to UAE projects requiring a durable Cat 6 data point in commercial, residential, retail, hospitality, warehouse or light-industrial environments. Final acceptance depends on compliance with the approved material submittal, project specifications, local authority requirements and structured-cabling standards. Contractors should also verify any required LSZH, fire-stopping, shielding and civil-defence provisions for the installation area.
How should the completed RJ45 data point be tested and commissioned?
After termination, use a calibrated cable certifier to test wire map, link length, insertion loss, return loss, near-end crosstalk and other parameters required for Cat 6 certification. Basic continuity testing can identify open, shorted or reversed conductors but does not prove Cat 6 performance. Test reports should identify the outlet and patch-panel port and be included in project handover documentation where required.
Can the ABB BM329 be used for PoE devices such as CCTV cameras and wireless access points?
It can form part of a Power over Ethernet link when the complete channel, cable, connectors, patch panel and network switch are compatible with the required PoE standard and device load. Correct conductor termination, cable-bundle management and heat control are important, particularly in UAE ceiling voids and service spaces where ambient temperatures can be high. Confirm the project's PoE and thermal design requirements before installation.
What installation practices help maintain Cat 6 network performance?
Avoid excessive cable pulling force, sharp bends, tight cable ties, kinks and unnecessary untwisting of conductor pairs. Keep the cable jacket close to the termination, use compatible termination tools, maintain separation from electrical interference sources and do not exceed the permitted channel length. Each outlet should be labelled and certified after installation to support reliable operation and future maintenance.
What should buyers verify before ordering the ABB BM329 data outlet?
Confirm model number BM329, the required number of data positions, mounting method, compatible back box, RJ45 module format, cable shielding type, termination arrangement and project finish. Buyers should also check whether matching boxes, glands, conduit adaptors, patch panels, Cat 6 cable and patch cords are required separately. Where a consultant-approved brand schedule applies, compare the product data with the approved material submittal before procurement.
Frequently Asked Questions
The ABB BM329 is a metal-clad, two-gang RJ45 data outlet designed for terminating Cat 6 structured network cabling. It provides a durable connection point for Ethernet networks in offices, workshops, warehouses, plant rooms, commercial buildings and residential utility areas. Its metal-clad construction is particularly suitable for locations where a more robust accessory is preferred over a standard plastic data outlet.
The outlet can be used for wired LAN connections serving computers, IP telephones, wireless access points, printers, network-enabled equipment, CCTV systems and building-management devices. It is suitable for new construction, fit-out, renovation and network-upgrade projects across UAE residential, commercial and light-industrial properties.
A correctly installed Cat 6 permanent link can support Gigabit Ethernet at channel lengths of up to 100 metres, subject to the cable, patch panels, patch cords, connectors and installation quality meeting Cat 6 requirements. Higher network speeds may be possible over shorter distances under applicable cabling standards, but the complete channel must be designed, installed and tested for the intended application.
Metal-clad accessories provide a robust surface finish for areas exposed to frequent use or a higher risk of impact. They are commonly specified in workshops, warehouses, back-of-house spaces, service corridors and utility rooms. The metal enclosure does not, by itself, confirm that the data link is shielded; shielding depends on the RJ45 module, cable, termination method and earthing design.
Installation should be completed by a qualified ELV or structured-cabling technician. Plan the outlet position, install the compatible mounting box or containment, route the Cat 6 cable without crushing or excessive bending, maintain the cable twists close to each termination, terminate all conductors using the specified T568A or T568B scheme, secure the module and faceplate, label each port and test the completed link. Follow ABB installation instructions and the project consultant's approved drawings and specifications.
Either T568A or T568B may be used when supported by the installed module and project specification. The same wiring scheme must be maintained at both ends of the link. T568B is common in many commercial installations, but contractors should follow the approved structured-cabling schedule and existing site convention to avoid crossed or incorrectly mapped connections.
Use genuine Cat 6 horizontal cable with conductor type, shielding classification and fire-performance rating suitable for the project. Solid-conductor cable is generally used for permanent building links, while stranded patch cords are used between the outlet and connected equipment. Cable and connector categories should match, and indoor, outdoor, LSZH or fire-rated cable must be selected according to the route, environment and UAE project requirements.
Data cables should be segregated from mains power wiring to reduce electromagnetic interference and comply with the project's ELV requirements. Use dedicated containment or the specified separation distance, cross power cables at approximately 90 degrees where necessary, and avoid routing data cable beside high-load circuits, motors or variable-frequency drives. Applicable local authority requirements, consultant specifications and standards such as ISO/IEC 11801 and ANSI/TIA-568 should be followed.
Metal-clad outlets are commonly selected for surface-mounted installations using a compatible box, conduit or trunking arrangement. Compatibility depends on the selected mounting box, entry method, back-box depth and cable bend radius. Confirm the required ABB accessories and dimensions before ordering, especially where galvanised conduit or industrial trunking is specified.
The outlet should not be assumed to be weatherproof unless the complete assembly has a manufacturer-declared IP rating suitable for outdoor use. For exposed UAE locations, install it inside an appropriately rated weatherproof enclosure and protect the cable from heat, ultraviolet exposure, dust, moisture and water ingress. Outdoor cable should have a suitable sheath, and all penetrations must be correctly sealed.
Yes, the ABB BM329 is relevant to UAE projects requiring a durable Cat 6 data point in commercial, residential, retail, hospitality, warehouse or light-industrial environments. Final acceptance depends on compliance with the approved material submittal, project specifications, local authority requirements and structured-cabling standards. Contractors should also verify any required LSZH, fire-stopping, shielding and civil-defence provisions for the installation area.
After termination, use a calibrated cable certifier to test wire map, link length, insertion loss, return loss, near-end crosstalk and other parameters required for Cat 6 certification. Basic continuity testing can identify open, shorted or reversed conductors but does not prove Cat 6 performance. Test reports should identify the outlet and patch-panel port and be included in project handover documentation where required.
It can form part of a Power over Ethernet link when the complete channel, cable, connectors, patch panel and network switch are compatible with the required PoE standard and device load. Correct conductor termination, cable-bundle management and heat control are important, particularly in UAE ceiling voids and service spaces where ambient temperatures can be high. Confirm the project's PoE and thermal design requirements before installation.
Avoid excessive cable pulling force, sharp bends, tight cable ties, kinks and unnecessary untwisting of conductor pairs. Keep the cable jacket close to the termination, use compatible termination tools, maintain separation from electrical interference sources and do not exceed the permitted channel length. Each outlet should be labelled and certified after installation to support reliable operation and future maintenance.
Confirm model number BM329, the required number of data positions, mounting method, compatible back box, RJ45 module format, cable shielding type, termination arrangement and project finish. Buyers should also check whether matching boxes, glands, conduit adaptors, patch panels, Cat 6 cable and patch cords are required separately. Where a consultant-approved brand schedule applies, compare the product data with the approved material submittal before procurement.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy