ABB

ABB Millenium 13A Fused Connection Unit with Flex and LED Dune Sand AM50853-DU

In Stock
135.19
EXCL.VAT
Incl. 5% VAT AED 141.95

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • 13A rating suits the specified electrical load.
    • Switched control provides convenient local operation.
    • An LED indicator shows the operating status.
    • Flush mounting keeps fixed wiring concealed.
    • Secure terminals support dependable connections.
    • The matching frame completes the installed finish.

Features & Benefits

Local Power Control

The integrated control mechanism provides convenient switching or connection for the specified fixed electrical circuit.

Rated Current

13A is the documented current rating for the stated outlet or connection-unit configuration.

LED Status Indication

The integrated LED gives a clear visual indication of the switch or connected-circuit status.

Secure Cable Termination

The terminal arrangement supports dependable fixed-wiring connections when correctly installed.

Flush Installation

The concealed mounting arrangement keeps permanent wiring behind the finished wall surface.

Key Specifications

Custom Stock Status

In Stock

Weight

0.18 kg

Color

Dune Sand

Quantity Unit

PCS

Model No

AM50853-DU

Brands

ABB

Item Type

Fused Connection Unit

Number of Gang

1 Gang

Rated Current

13A

Rated Voltage

230V AC

Connector Type

Fused Connection Unit

Dimension

42 x 86 x 86 mm

Height

86 mm

Width

86 mm

Depth

42 mm

Usage

Protected fixed appliance connection with status indication

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Millenium AM50853-DU is a 1-gang, flush-mounted fused connection unit designed to connect and locally control a fixed electrical appliance through a flex outlet. It is rated at 13A and 230V AC and includes a switch, an LED status indicator, secure wiring terminals and a Dune Sand finish.

Not as a direct like-for-like replacement in every application. A fused connection unit is intended to provide a controlled, fused connection for an appliance flex rather than a general-purpose plug-in outlet. Any conversion from a socket outlet must be reviewed for circuit arrangement, load, cable protection, accessibility and compliance with the electrical design.

The Dune Sand colour provides a coordinated, understated finish for contemporary villas, apartments, hotels and commercial interiors. Flush mounting conceals permanent wiring, while the matching ABB Millenium frame gives the installation a clean appearance. Designers should confirm the colour and frame compatibility against the approved project sample before bulk procurement.

Use a flex type and conductor size suitable for the appliance current, operating temperature and installation environment. Route it through the designated outlet, provide effective strain relief and avoid sharp bends, crushing or contact with hot surfaces. Periodic inspection should look for discoloration, looseness, heat damage or a deteriorated flex; any defect should be assessed by a qualified electrician.

Contractors should check conductor identification, terminal tightness, earth continuity, insulation resistance, polarity, protective-device coordination, fuse suitability and functional operation of the switch and LED. The flex should be securely retained without damaged insulation or exposed copper. Test results should be recorded as required by the project specification and relevant UAE authority.

The integrated switch provides convenient local control, but complete isolation should not be assumed solely from the switch position or LED status. Whether it meets a specific isolation requirement depends on its certified switching arrangement and the project design. Safe servicing requires isolation at the appropriate upstream device, lockout where necessary and verification that the circuit is dead.

It may be used in an appropriate indoor location when allowed by the project design, but no water- or dust-protection rating is stated in the supplied specifications. It should not be installed in a wet, exposed or outdoor position unless the complete enclosure and installation provide the required IP rating and comply with local zoning rules. Bathroom and wash-area installations require particular attention to permitted locations, isolation and additional protection.

Yes, its 230V AC rating and 13A capacity are relevant to many residential, commercial and hospitality installations in the UAE. Final selection and installation must comply with the latest UAE electrical requirements and the regulations of the applicable local authority, such as DEWA, Abu Dhabi distribution authorities or SEWA, as relevant to the project.

The listed product dimensions are approximately 42 x 86 x 86 mm, with a nominal face width of 86 mm. Installers should verify the compatible flush box, available wall depth, cable bend radius and terminal clearance before first-fix work. The finished opening and box alignment should also suit the ABB Millenium frame and accessory configuration.

The unit is intended for flush mounting, with the fixed wiring and mounting box concealed behind the finished wall. Installation generally involves isolating and proving the circuit dead, checking the back-box fit and cable capacity, terminating line, neutral and earth conductors at the marked terminals, fitting the correct fuse, securing the appliance flex and assembling the matching frame. A UAE-licensed electrician should complete installation and testing in accordance with ABB instructions and local regulations.

The integrated LED provides a visible indication of the switch or connected-circuit status, helping users identify when the unit is operating. The LED must not be treated as proof that the circuit is electrically isolated. Before maintenance, the supply should be isolated at the distribution board and verified using an approved voltage-testing procedure.

The fuse provides local overcurrent protection for the appliance flex and connected equipment. The installed fuse must be selected according to the appliance manufacturer’s requirements, flex capacity and circuit design; it should not automatically be assumed that every appliance requires a 13A fuse. The upstream circuit breaker and other required protective devices remain essential.

The connection unit has a documented rated current of 13A and a rated voltage of 230V AC. These ratings suit common UAE low-voltage installations, but the connected load must not exceed the unit, circuit, cable or protective-device capacity. Applicable derating and installation conditions should also be considered.

It is suitable for compatible fixed or semi-fixed appliances that require a fused flex connection and local switching, subject to the appliance load and manufacturer’s instructions. Typical construction applications may include water heaters, exhaust fans, kitchen equipment and other permanently connected equipment. The circuit design, fuse rating and appliance suitability must be confirmed by a qualified electrician.

The ABB Millenium AM50853-DU is a 1-gang, flush-mounted fused connection unit designed to connect and locally control a fixed electrical appliance through a flex outlet. It is rated at 13A and 230V AC and includes a switch, an LED status indicator, secure wiring terminals and a Dune Sand finish.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy