ABB Millenium 45A Cooker Control Unit with 13A Switched Socket Dune Sand AM118147-DU

In Stock
195.75
EXCL.VAT
Incl. 5% VAT AED 205.54

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • 45A rating suits the specified electrical load.
    • Switched control provides convenient local operation.
    • Flush mounting keeps fixed wiring concealed.
    • Secure terminals support dependable connections.
    • The matching frame completes the installed finish.

Features & Benefits

Local Power Control

The integrated control mechanism provides convenient switching or connection for the specified fixed electrical circuit.

Rated Current

45A is the documented current rating for the stated outlet or connection-unit configuration.

Secure Cable Termination

The terminal arrangement supports dependable fixed-wiring connections when correctly installed.

Flush Installation

The concealed mounting arrangement keeps permanent wiring behind the finished wall surface.

Millenium System Coordination

The mechanism and decorative finish coordinate with compatible ABB Millenium frames and accessories.

Key Specifications

Custom Stock Status

In Stock

Weight

0.35 kg

Color

Dune Sand

Quantity Unit

PCS

Model No

AM118147-DU

Brands

ABB

Item Type

Cooker Switch

Number of Gang

2 Gang

Pole

2 Pole

Rated Current

45A

Rated Voltage

250V AC

Connector Type

BS 13A Switched Socket Outlet

Dimension

42 x 147 x 86 mm

Switch Type

Cooker Control Switch and Switched Socket

Height

86 mm

Width

147 mm

Depth

42 mm

Usage

Cooker isolation with auxiliary 13A socket

Installation Type

Flush Mounted

Frequently Asked Questions

The ABB Millenium AM118147-DU is a flush-mounted cooker control unit combining a 45A cooker control switch with a BS 13A switched socket outlet. It is designed to provide convenient local isolation for a compatible fixed cooking appliance while also offering a general-purpose socket. The unit has a Dune Sand finish and coordinates with compatible ABB Millenium frames and accessories.

The AM118147-DU combines high-current local cooker control, a convenient BS 13A switched socket, concealed flush mounting, secure fixed-wiring terminals, and coordinated ABB Millenium styling in one unit. This makes it a practical specification option for UAE residential construction and kitchen renovation projects where the circuit design requires a 45A-rated cooker control point and a matching Dune Sand finish.

Before energising, the electrician should inspect conductor identification, terminal tightness, earthing, cable condition, back-box clearance, and faceplate alignment. Electrical testing should then verify protective-conductor continuity, insulation resistance, polarity, protective-device operation, and applicable fault or RCD performance. Finally, both the cooker control switch and the 13A switched socket should be functionally tested under safe conditions.

The Dune Sand colour provides a warm neutral appearance that can complement beige stone, timber, cream cabinetry, and earth-toned kitchen finishes often used in UAE villas and apartments. For a consistent result, specify compatible ABB Millenium frames and adjacent wiring accessories in the same finish, as colours may appear different across unrelated product ranges or under different lighting.

The listed installation type is flush mounted, so it should not be treated as a surface-mounted product unless ABB specifies a compatible surface enclosure. No outdoor or ingress-protection rating is provided in the supplied product data. It should therefore be installed in a dry indoor location and not exposed to rain, wash-down water, condensation, excessive dust, or outdoor UAE heat unless housed in a specifically approved protective enclosure.

Yes, the circuit protective conductor must be correctly terminated and earth continuity verified in accordance with the approved wiring design. Required overcurrent protection, residual-current protection, and isolation arrangements depend on the distribution system, circuit configuration, local authority rules, and current project standards. Testing should include continuity, insulation resistance, polarity, earth-fault protection, and functional operation, with results recorded where required.

Yes. It is suitable for coordinated installation in villas, apartments, staff accommodation, and commercial fit-out projects where a 45A cooker circuit and BS 13A socket are specified. During first-fix work, contractors should coordinate the dedicated circuit, conduit, back box, earthing, wall depth, and final cooker position. During second fix, the mechanism and matching frame should be fitted only after dusty or wet finishing work is complete.

It should be readily accessible for local isolation and positioned so the user does not need to reach over the hob or cooking surface. It should also be kept away from sinks, direct water exposure, excessive heat, steam, and areas where cabinetry or appliances obstruct access. Exact location and separation requirements must follow the approved kitchen layout, project electrical specification, local regulations, and appliance manufacturer's instructions.

Cable size and protective-device rating cannot be selected from the switch rating alone. A qualified electrical designer or electrician must calculate them using the cooker's connected load, permissible demand or diversity rules, installation method, ambient temperature, grouping, cable length, voltage drop, fault-loop conditions, and local authority requirements. The protective device must protect the cable and circuit while remaining compatible with the appliance and the 45A control unit.

The product is intended for flush installation, but the required back-box type and minimum depth depend on the mechanism, terminal space, cable size, frame, and wall construction. A box must provide enough room for the relatively heavy cooker-circuit conductors without sharp bends, crushed insulation, or stress on the terminals. Check the ABB installation sheet and the listed dimensions before closing blockwork, drywall, joinery, or kitchen wall finishes.

Installation should be completed by a licensed electrician with the circuit isolated, locked off where required, and proven dead. The electrician should install a compatible flush back box, route the fixed wiring without damaging insulation, connect line, neutral, earth, load, and socket conductors strictly according to the ABB terminal markings and wiring diagram, tighten terminals to the specified torque, fit the compatible Millenium frame, and test the completed circuit before energising it.

Its 250V AC rating and BS 13A socket format are relevant to the UAE's nominal 230V, 50Hz low-voltage supply and commonly used Type G plug system. Final suitability depends on the project specification and the requirements of the relevant UAE authority, such as DEWA, ADDC, SEWA, or the applicable local utility and municipality. Installation should follow current UAE regulations and relevant BS or IEC wiring practices adopted for the project.

Yes, the BS 13A switched socket is suitable for compatible 13A fused plugs commonly used in the UAE, subject to the circuit design and connected load. It may be used for suitable countertop or kitchen equipment, but high-load appliances should not be connected through adaptors or overloaded extension leads. Confirm from the ABB wiring diagram whether the socket operation is independent of the cooker switch in the intended installation.

It can be used as the local control and isolation point for an electric cooker, hob, oven, or similar fixed cooking appliance when the appliance load, circuit design, cable size, protective device, and manufacturer requirements are compatible with the unit's 45A rating. The appliance's nameplate load and installation instructions must be checked because not every cooker requires the same circuit arrangement.

The unit is rated at 45A and 250V AC and uses a two-gang configuration. It incorporates a cooker control switch and a BS 13A switched socket outlet, supports concealed fixed-wiring termination, and is intended for flush mounting. Its listed dimensions are approximately 42 x 147 x 86 mm; installers should confirm the dimension order, wall-box depth, and frame compatibility against the ABB technical documentation before installation.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy