ABB

ABB Weatherproof 2 Gang 2 Way 16AX Switch IP66 WSW221

In Stock
121.50
EXCL.VAT
Incl. 5% VAT AED 127.58

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • It features two gangs with two-way switching.
    • The switch is rated at 16AX for reliable control.
    • Its IP66 enclosure resists dust and water jets.
    • The weatherproof housing suits exposed locations.
    • The robust cover protects both switch rockers.

Features & Benefits

2 Gang Switch Configuration

The dual-gang design provides two independently operated switch controls within one weatherproof enclosure, allowing convenient management of two separate lighting circuits or compatible electrical loads from a single location.

2 Way Switching

Each switch supports two-way operation, enabling a circuit to be controlled from two different locations when paired with a compatible two-way switch. This is particularly useful for entrances, corridors, stairways, garages and larger outdoor areas.

16AX Rated Switching Capacity

The 16AX rating is designed for demanding lighting applications, including compatible fluorescent and other lighting loads that may produce higher inrush currents. The connected load must remain within the switch rating and applicable circuit requirements.

IP66 Weatherproof Protection

The IP66-rated enclosure is dust-tight and resistant to powerful water jets when correctly installed, making the switch suitable for exposed, damp or dusty locations such as gardens, balconies, workshops, utility areas and covered outdoor spaces.

ABB WSW221

Manufactured by ABB under model WSW221, this switch combines weather-resistant circuit control with a practical two-gang format for residential, commercial and light industrial electrical installations.

Installation Requirements

For reliable IP66 performance, the enclosure, cable entries, seals and mounting surfaces must be correctly fitted and maintained. Installation should be completed by a qualified electrician in accordance with the UAE electrical regulations and the requirements of the relevant local authority.

Key Specifications

Custom Stock Status

In Stock

Quantity Unit

PCS

Model No

WSW221

Brands

ABB

Item Type

IP Switch

Material

Polycarbonate

Number of Gang

2 Gang

Number of Ways

2 Way

Rated Current

16AX

Rated Voltage

250V AC

Switch Type

2-way

Usage

Outdoor two-way control of two lighting circuits

Installation Type

Surface Mounted

Frequently Asked Questions

The ABB WSW221 is a weatherproof electrical switch featuring two independently operated gangs, two-way switching capability, a 16AX rating and an IP66 enclosure. It is designed for controlling lighting or other compatible fixed electrical loads in outdoor, dusty, humid or wash-down-prone locations when correctly installed.

Two gang means the unit contains two separate switch mechanisms, allowing two circuits or lighting groups to be controlled from one location. Two way means each gang can form part of a circuit controlled from two different positions, such as at both ends of a corridor, beside two entrances or at the top and bottom of an external staircase. It may also be wired for conventional one-location switching where appropriate.

The 16AX marking denotes a 16 A switch rating with additional suitability for certain lighting loads that can produce higher switching inrush currents. The actual connected load must still be checked against the lamp driver, ballast, circuit protection, cable size, installation method and local electrical requirements. A qualified electrician should verify compatibility before connection.

IP66 indicates complete protection against dust ingress and protection against powerful water jets when the product is assembled, sealed and installed according to the manufacturer's instructions. This makes the WSW221 suitable for many exposed UAE environments. IP66 does not mean the switch can be submerged, and the rating may be compromised by incorrect cable entries, damaged seals, loose covers or unsuitable glands.

Typical applications include villa gardens, balconies, terraces, garages, workshops, warehouses, plant rooms, construction service areas, car parks, external corridors, utility zones and covered outdoor kitchens. It can control compatible outdoor lights, security lighting or other fixed loads within its electrical rating. Suitability for a specific appliance, motor or inductive load must be confirmed from the equipment specifications.

Yes, its sealed IP66 design makes it relevant for UAE sites exposed to dust, sand, humidity and occasional rain or cleaning water. For locations receiving intense direct sunlight or extreme heat, installers should also consider the manufacturer's permitted ambient temperature, mounting position, UV exposure and any required shading. It should not be installed in continuously submerged, hazardous or marine-corrosive locations unless specifically approved for those conditions.

Installation should be completed by a licensed electrician with the circuit isolated, locked out where required and proven dead. The installer should securely mount the enclosure, use correctly sized weatherproof glands, route conductors without damaging insulation, connect line and switched conductors according to the ABB terminal diagram, provide earthing where required, tighten terminals to the specified torque and correctly seat every gasket and cover. The completed circuit should then undergo continuity, insulation, polarity, functional and protective-device testing.

Use cable glands, conduit fittings, adaptors and sealing accessories that match the cable or conduit diameter and maintain at least the required enclosure protection. Unused entries must be closed with suitable weatherproof blanking plugs. Outdoor cable entries should be arranged to reduce water tracking, and additional openings should not be drilled unless ABB permits them because modifications can invalidate the IP66 performance.

Yes. Each two-way gang can be connected with another compatible two-way switch to control the same lighting circuit from two locations. This is useful for garden paths, external staircases, long corridors, warehouses and areas with more than one access point. Correct strapper wiring and terminal identification are essential, so the circuit should be designed and connected by a qualified electrician.

Yes, the two gangs can generally operate separate compatible lighting circuits or lighting groups. Before using different circuit supplies in one enclosure, the electrician must confirm that the product design, isolation arrangement, identification, segregation and local wiring rules permit it. Clear circuit labelling is recommended for safe construction-site handover and future maintenance.

It can be used with compatible LED lighting when the total operating current and, importantly, the LED driver's inrush current remain within the switch and circuit limits. Multiple LED drivers can create a high momentary current even when their combined wattage appears low. Review the driver manufacturer's data and have the circuit assessed by an electrical professional.

Do not select it for a motor, pump, compressor, water heater or other demanding load solely from the 16AX marking. Such equipment may have high starting current and may require a suitably rated isolator, contactor, overload protection or dedicated control system. The equipment nameplate, load category and ABB technical documentation should be checked by an electrical engineer or qualified electrician.

The installation should comply with the applicable UAE authority regulations and approved project specifications, such as requirements issued by the relevant emirate's electricity and water authority. Correct conductor sizing, circuit protection, earthing, residual-current protection where required, enclosure location, approved materials, testing and certification must all be considered. Requirements can differ by emirate and project type, so approval should be confirmed with the consultant or local authority.

Mount it on a firm, level surface where it remains accessible for operation and maintenance. Avoid low points where water can collect, locations vulnerable to impact and positions directly exposed to irrigation jets or chemical cleaning where practical. Cable routing should be supported, entries should remain sealed, and the mounting height and accessibility should follow project drawings, authority rules and user requirements.

Inspect the enclosure periodically for cracked parts, loose fasteners, degraded seals, damaged glands and moisture ingress. Keep the operating surface clean using methods compatible with the enclosure material, and do not use aggressive solvents. Always isolate the circuit before opening the unit, replace damaged sealing components with approved parts and ensure the cover is correctly refitted after maintenance.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy