FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- Rated at 45 A for dependable load isolation.
- Two poles disconnect line and neutral conductors.
- IP66 enclosure blocks dust and powerful water jets.
- Clear cover enables quick switch-position inspection.
- Rotary control provides secure ON and OFF switching.
- Weatherproof housing supports exposed installations.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
45 A Rated Current
The 45-ampere current rating supports demanding electrical loads, making the isolator suitable for equipment such as water heaters, air-conditioning systems, pumps and other fixed appliances when selected in accordance with the connected load and installation requirements.
Double-Pole Isolation
The two-pole switching arrangement isolates both live and neutral conductors, providing a clear and dependable means of disconnecting connected equipment for maintenance, servicing or emergency shutdown.
IP66 Weatherproof Protection
The IP66-rated enclosure is dust-tight and protected against powerful water jets, making it suitable for exposed indoor or outdoor locations where dust, rain, moisture and routine washdown may be present.
Heavy-Duty Switch Isolator
Designed to provide local control and electrical isolation for higher-current fixed equipment, this unit offers a practical solution for residential, commercial and light-industrial installations requiring a robust point of disconnection.
ABB Model WSD245CL
Manufactured by ABB, the WSD245CL combines a recognised electrical brand with a weather-resistant format intended for reliable operation in demanding installation environments.
Suitable for UAE Installations
The isolator is appropriate for use within UAE low-voltage electrical installations when its 45 A rating, circuit protection, cable size and environmental conditions are verified by a qualified electrician against applicable local authority regulations and the current UAE wiring requirements.
Professional Fixed Installation
The enclosure is intended for secure fixed mounting near the connected equipment, helping provide accessible local isolation. Installation, termination and testing should be completed by a licensed electrician using correctly rated cables, protective devices and suitable weatherproof accessories.
Key Specifications
Custom Stock Status
In Stock
Weight
0.45 kg
Quantity Unit
PCS
Model No
WSD245CL
Brands
ABB
Item Type
Isolator Switch
Pole
2 Pole
Rated Current
45A
Rated Voltage
240V AC
Switch Type
ON/OFF isolation
Height
94 mm
Width
180 mm
Depth
85 mm
Usage
Outdoor equipment isolation
Installation Type
Surface Mounted
Frequently Asked Questions
What is the ABB WSD245CL Weatherproof 45A 2 Pole Switch Isolator?
The ABB WSD245CL is a heavy-duty, weatherproof electrical isolator designed to disconnect both poles of a circuit for safer maintenance and emergency isolation. It has a rated current of 45A and an IP66 enclosure, making it suitable for demanding indoor and outdoor electrical installations where protection against dust, rain and powerful water jets is required.
What does the IP66 rating of the ABB 45A isolator mean?
IP66 means the enclosure is dust-tight and protected against powerful water jets when correctly installed, closed and maintained. This rating makes the ABB weatherproof isolator suitable for exposed UAE environments such as construction sites, workshops, plant rooms and outdoor service areas. IP66 does not mean that the switch can be continuously submerged in water.
Why does the ABB WSD245CL use a 2 pole isolation mechanism?
A 2 pole isolator simultaneously disconnects two conductors, typically live and neutral in an appropriate single-phase circuit. This provides more complete circuit separation than switching only the live conductor. The required isolation arrangement must be confirmed by a qualified electrician according to the circuit design, earthing system and applicable UAE authority requirements.
What applications are suitable for this ABB weatherproof 45A switch isolator?
The ABB WSD245CL can be used as a local isolation point for compatible electrical loads, including selected air-conditioning equipment, pumps, water heaters, workshop machinery, outdoor equipment and building services. It is also relevant for MEP works and construction projects requiring a durable, accessible disconnecting device. The equipment load, starting current and manufacturer requirements must be checked before selection.
Can the ABB WSD245CL isolator be installed outdoors in the UAE?
Yes, its IP66 enclosure is intended for demanding outdoor and wet-area conditions when installed correctly. For UAE use, position it away from locations vulnerable to flooding, standing water, direct mechanical impact or excessive heat wherever possible. Suitable UV-resistant cables, weatherproof glands, corrosion-resistant fixings and properly sealed entries should be used to preserve the enclosure protection.
Is a 45A isolator suitable for an air conditioner or HVAC unit?
It may be suitable for an HVAC unit where the equipment nameplate current, cable rating, protective device and manufacturer instructions are compatible with a 45A isolator. HVAC compressors can have significant starting currents, so selection should not be based only on normal running current. A qualified electrical engineer or electrician should verify the load characteristics, utilization category and local isolation requirements.
How should the ABB Weatherproof 45A 2 Pole Switch Isolator be installed?
Installation should be completed by a licensed or qualified electrician. The incoming supply must be safely isolated and verified dead before work begins. Mount the enclosure securely, use cable glands and conductors of the correct type and size, connect the supply and load conductors to the identified terminals, tighten terminals to ABB's specified torque, maintain the required earthing continuity, seal unused openings and test the circuit before energizing it. Always follow the ABB installation instructions supplied with the product.
What cable size should be used with the ABB WSD245CL 45A isolator?
Cable size cannot be selected from the 45A switch rating alone. It depends on the design current, protective-device rating, cable material and insulation, installation method, ambient temperature, grouping, route length and permitted voltage drop. UAE outdoor temperatures can require substantial derating, so the conductor size and terminal compatibility should be confirmed through an electrical design calculation.
How can installers maintain the IP66 protection during installation?
Use correctly sized IP-rated cable glands, make cable entries only at approved positions, fit all seals and gaskets properly, close unused openings with suitable weatherproof plugs and ensure the cover is evenly secured. Avoid damaging the enclosure or gasket and route cables to reduce water tracking into entries. Drilling unauthorized holes or using mismatched glands can reduce the effective ingress-protection rating.
Does this isolator replace an MCB, RCBO or other circuit protection device?
No. An isolator is primarily intended for switching and safe disconnection; it does not automatically provide overcurrent, short-circuit or earth-leakage protection unless specifically stated in ABB documentation. The circuit may still require an appropriately rated MCB, fuse, RCBO or RCD selected according to the load, cable and applicable electrical regulations.
Is the ABB WSD245CL relevant to UAE construction and MEP projects?
Yes. Its 45A capacity, 2 pole switching and IP66 weatherproof construction make it relevant to villas, commercial buildings, workshops, temporary construction facilities and outdoor MEP services in the UAE. Project specifications should be checked against the current requirements of the relevant authority, such as DEWA, ADDC, SEWA or EtihadWE, together with applicable UAE regulations and BS 7671-based design practices where adopted.
What checks should be performed before commissioning the ABB isolator?
Before energization, check conductor identification, terminal tightness, polarity, earthing continuity, insulation resistance, enclosure sealing and secure mounting. Confirm that the switch operates correctly, the load is within the approved rating and the upstream protection is properly coordinated. Inspection and test results should be recorded as part of the project's electrical testing and commissioning documentation.
What maintenance does an ABB IP66 weatherproof isolator require?
Periodically inspect the enclosure for cracks, UV degradation, corrosion, loose mounting, damaged glands, deteriorated seals, water entry or heat discoloration. With the circuit safely isolated, a qualified electrician should check terminal condition and tightness in accordance with ABB guidance. Inspection frequency should reflect the environment, with more frequent checks on construction sites, coastal locations and dusty industrial premises.
What should buyers verify before ordering the ABB WSD245CL switch isolator?
Confirm that the model number WSD245CL, 45A current rating, 2 pole configuration and IP66 protection match the approved electrical design. Buyers should also verify the circuit voltage and frequency, load type, switching duty, cable-entry requirements, conductor terminal capacity, mounting location and any project-specific approvals using the latest ABB technical datasheet and consultant specifications.
Frequently Asked Questions
The ABB WSD245CL is a heavy-duty, weatherproof electrical isolator designed to disconnect both poles of a circuit for safer maintenance and emergency isolation. It has a rated current of 45A and an IP66 enclosure, making it suitable for demanding indoor and outdoor electrical installations where protection against dust, rain and powerful water jets is required.
IP66 means the enclosure is dust-tight and protected against powerful water jets when correctly installed, closed and maintained. This rating makes the ABB weatherproof isolator suitable for exposed UAE environments such as construction sites, workshops, plant rooms and outdoor service areas. IP66 does not mean that the switch can be continuously submerged in water.
A 2 pole isolator simultaneously disconnects two conductors, typically live and neutral in an appropriate single-phase circuit. This provides more complete circuit separation than switching only the live conductor. The required isolation arrangement must be confirmed by a qualified electrician according to the circuit design, earthing system and applicable UAE authority requirements.
The ABB WSD245CL can be used as a local isolation point for compatible electrical loads, including selected air-conditioning equipment, pumps, water heaters, workshop machinery, outdoor equipment and building services. It is also relevant for MEP works and construction projects requiring a durable, accessible disconnecting device. The equipment load, starting current and manufacturer requirements must be checked before selection.
Yes, its IP66 enclosure is intended for demanding outdoor and wet-area conditions when installed correctly. For UAE use, position it away from locations vulnerable to flooding, standing water, direct mechanical impact or excessive heat wherever possible. Suitable UV-resistant cables, weatherproof glands, corrosion-resistant fixings and properly sealed entries should be used to preserve the enclosure protection.
It may be suitable for an HVAC unit where the equipment nameplate current, cable rating, protective device and manufacturer instructions are compatible with a 45A isolator. HVAC compressors can have significant starting currents, so selection should not be based only on normal running current. A qualified electrical engineer or electrician should verify the load characteristics, utilization category and local isolation requirements.
Installation should be completed by a licensed or qualified electrician. The incoming supply must be safely isolated and verified dead before work begins. Mount the enclosure securely, use cable glands and conductors of the correct type and size, connect the supply and load conductors to the identified terminals, tighten terminals to ABB's specified torque, maintain the required earthing continuity, seal unused openings and test the circuit before energizing it. Always follow the ABB installation instructions supplied with the product.
Cable size cannot be selected from the 45A switch rating alone. It depends on the design current, protective-device rating, cable material and insulation, installation method, ambient temperature, grouping, route length and permitted voltage drop. UAE outdoor temperatures can require substantial derating, so the conductor size and terminal compatibility should be confirmed through an electrical design calculation.
Use correctly sized IP-rated cable glands, make cable entries only at approved positions, fit all seals and gaskets properly, close unused openings with suitable weatherproof plugs and ensure the cover is evenly secured. Avoid damaging the enclosure or gasket and route cables to reduce water tracking into entries. Drilling unauthorized holes or using mismatched glands can reduce the effective ingress-protection rating.
No. An isolator is primarily intended for switching and safe disconnection; it does not automatically provide overcurrent, short-circuit or earth-leakage protection unless specifically stated in ABB documentation. The circuit may still require an appropriately rated MCB, fuse, RCBO or RCD selected according to the load, cable and applicable electrical regulations.
Yes. Its 45A capacity, 2 pole switching and IP66 weatherproof construction make it relevant to villas, commercial buildings, workshops, temporary construction facilities and outdoor MEP services in the UAE. Project specifications should be checked against the current requirements of the relevant authority, such as DEWA, ADDC, SEWA or EtihadWE, together with applicable UAE regulations and BS 7671-based design practices where adopted.
Before energization, check conductor identification, terminal tightness, polarity, earthing continuity, insulation resistance, enclosure sealing and secure mounting. Confirm that the switch operates correctly, the load is within the approved rating and the upstream protection is properly coordinated. Inspection and test results should be recorded as part of the project's electrical testing and commissioning documentation.
Periodically inspect the enclosure for cracks, UV degradation, corrosion, loose mounting, damaged glands, deteriorated seals, water entry or heat discoloration. With the circuit safely isolated, a qualified electrician should check terminal condition and tightness in accordance with ABB guidance. Inspection frequency should reflect the environment, with more frequent checks on construction sites, coastal locations and dusty industrial premises.
Confirm that the model number WSD245CL, 45A current rating, 2 pole configuration and IP66 protection match the approved electrical design. Buyers should also verify the circuit voltage and frequency, load type, switching duty, cable-entry requirements, conductor terminal capacity, mounting location and any project-specific approvals using the latest ABB technical datasheet and consultant specifications.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
