PowerSafe

PowerSafe Power Supply 2A Input 110-220V Output 12V PSPS 2A

In Stock
16.22
EXCL.VAT
Incl. 5% VAT AED 17.03

FREE Returns

Sign in & get up to 10% off your first order. Use code WELCOME10.

Upgrade to Fepy Pro and get up to 10% off all orders.

Delivery by Friday, 23 Oct

Standard delivery available
Free Delivery

    Key Features

    • 2A output suits compatible DC loads.
    • Provides a regulated 12V DC output connection.
    • Accepts a 110-220V AC mains input range.
    • Designed for fixed low-voltage power systems.
    • Model PSPS 2A supports clear product matching.
    • Select load capacity within the rated current.

Features & Benefits

Product Type

AC-DC Power Supply identified under PowerSafe model PSPS 2A, allowing buyers to match the exact product reference before ordering.

DC Output

The unit provides 12V DC at a rated 2A; connected equipment must remain within this output capacity.

Installation

Electrical installation should be completed by a qualified person in accordance with the product rating and applicable UAE authority requirements.

Key Specifications

Custom Stock Status

In Stock

Quantity Unit

PCS

Model No

PSPS 2A

Brands

PowerSafe

Item Type

AC-DC Power Supply

Frequency

50/60hz

AC Voltage

110-220V AC

Country Of Origin

China

Usage

Supplying compatible 12V DC electrical loads

DC Voltage

12V DC

Output Current

2A

Frequently Asked Questions

The PowerSafe PSPS 2A is an AC-to-DC power supply designed to provide a regulated 12V DC output for compatible low-voltage equipment. It has a rated output current of 2A and accepts an AC input stated as 110–220V. Buyers should confirm the model number, input rating, output voltage, connector type and polarity against the requirements of the equipment being powered.

The rated output is 12V DC at up to 2A, equivalent to a maximum nominal output of 24W. The total current drawn by all connected devices must not exceed 2A. For continuous operation, particularly in warm UAE environments, allowing suitable capacity headroom can help avoid operating the power supply continuously at its maximum rating.

It can supply compatible equipment that requires regulated 12V DC and draws no more than 2A. Potential applications include selected access-control devices, sensors, low-voltage control equipment, small CCTV accessories, alarm-system components and compatible LED control circuits. Compatibility must be checked from the device label or technical manual; matching voltage alone is not sufficient.

The PSPS 2A may be used for compatible low-voltage systems in villas, commercial buildings, workshops, site offices and other construction applications. The system designer must verify load current, cable size, voltage drop, installation location and environmental protection. Electrical work should comply with applicable UAE regulations and the requirements of the relevant local authority, consultant and project specification.

UAE low-voltage supplies are commonly based on a nominal 230V, 50Hz single-phase system. Because this product is stated as accepting 110–220V AC, do not assume it is suitable for every UAE mains circuit. Before installation, check the rating label and manufacturer documentation to confirm the permitted input-voltage tolerance and frequency. A qualified electrician should verify compatibility with the actual supply.

First isolate the electrical supply and confirm that the connected load requires 12V DC and remains within the 2A rating. Mount the unit in a secure, ventilated and accessible location, then connect the AC input and DC output only according to the terminal markings or manufacturer instructions. Verify output polarity before energising the load. Fixed wiring, enclosure selection, earthing where applicable, overcurrent protection and final testing should be handled by a qualified electrical professional.

Cable selection depends on load current, route length, installation method, ambient temperature and acceptable voltage drop. Voltage drop is especially important in 12V systems because even a relatively small cable loss can affect equipment performance. For long cable runs on construction projects, an electrician or system designer should calculate the required conductor size rather than selecting cable only by the 2A current rating.

Yes, provided every device is designed for 12V DC, the wiring arrangement is suitable and their combined maximum current does not exceed 2A. Include startup, surge or peak current where relevant rather than relying only on normal operating current. Individual branch protection or distribution terminals may also be required depending on the application and project design.

Outdoor suitability cannot be confirmed because no IP rating or weather-resistance classification is provided in the available specifications. Do not expose the unit directly to rain, irrigation water, dust, condensation or intense sunlight. If outdoor installation is required, place it in a correctly rated enclosure with appropriate cable entries, ventilation and thermal management selected for UAE site conditions.

High ambient temperatures, restricted airflow and installation inside crowded panels can increase operating temperature and reduce power-supply reliability. Install the unit away from direct sunlight and other heat-producing equipment, maintain ventilation clearance, and avoid enclosing it in an unsuitable unventilated box. Confirm the manufacturer's allowable operating-temperature range before using it in plant rooms, rooftops or external cabinets.

A 12V DC rating does not by itself guarantee compatibility. The positive and negative output polarity, connector dimensions, terminal arrangement and required current must match the connected equipment. Reversed polarity or an incorrect connector can damage the load. Check the device manual and power-supply markings, and test the output with suitable instruments before final connection when required.

Isolate the supply before inspection. Check the AC input against the PSPS 2A rating, confirm that the DC output is approximately 12V under load, verify polarity, inspect terminal tightness and calculate the total connected current. Also check for excessive cable voltage drop, short circuits, damaged wiring or a load that requires more than 2A during startup. Troubleshooting of fixed electrical installations should be performed by a qualified person.

The available product information does not state which protective functions are built into the unit. Do not assume that overload, short-circuit, overvoltage or thermal protection is included. Review the product label and manufacturer documentation, and provide suitable upstream and downstream circuit protection where required by the equipment design, UAE authority requirements and project specifications.

Confirm the exact model PSPS 2A, required 12V DC output, maximum load current, AC input compatibility, mains frequency, output polarity, connector or terminal type, installation dimensions, mounting method and environmental requirements. Contractors should also check consultant approvals, authority requirements and any project-specific product certification or submittal obligations before procurement.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy