Frequently Bought Together
Everything you need in one click

Schneider Electric 1P - 20A - C Curve - 6000A Miniature Circuit Braker (MCB)

Ducab PVC Single Core Cable, 1.5mm × 100m, Easy Pulling - Red

240mm x 12mm Cable lug

Gazelle G9101 Digital Multimeter
Individual Price
23.50Buy selected items separately
Bundle Price
Schneider Electric 1P - 20A - C Curve - 6000A Miniature Circuit Braker (MCB)
FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Thursday, 30 Jul
- 1P 20A Miniature Circuit-Breaker From Schneider Electric Domae.
- Rated For 6000A Short-Circuit Current.
- C Curve Rated For 10Ka Breaking Capacity.
- Ul, Cet, And Ccc Approved.
Key Features
Delivery by Thursday, 30 Jul

- 100% free subscription
- Easy Registration
Frequently Bought Together
Everything you need in one click

Schneider Electric 1P - 20A - C Curve - 6000A Miniature Circuit Braker (MCB)

Ducab PVC Single Core Cable, 1.5mm × 100m, Easy Pulling - Red

240mm x 12mm Cable lug

Gazelle G9101 Digital Multimeter
Individual Price
23.50Buy selected items separately
Bundle Price
Features & Benefits
1.Schneider Electric Domae MCB Miniature Circuit-Breaker is perfect for single-phase installations. This highly reliable breaker provides up to 20A with a C-curve tripping characteristic and a rated insulation voltage of 500V.
2.With this breaker, you can protect your circuits and electrical devices from overcurrent faults or short circuits with its low trip current of 0.03A and high interrupting capacity of 6000A. Its built-in indicator helps you identify a fault in the electrical system in a snap.
3.The Schneider Electric Domae MCB Miniature Circuit-Breaker is easy to install and requires no additional tools or components for installation. It is compact enough to fit in even the smallest spaces, making it perfect for small and light commercial installations.
4.Constructed with a thermoplastic housing, this breaker is robust and resistant to corrosion and UV light exposure. It passes all standard safety requirements and is UL 1077 listed. Additionally, the included 10-year warranty ensures peace of mind in knowing your electrical system is protected.
Key Specifications
Custom Stock Status
In Stock
Weight
0.21 kg
Color
White
Quantity Unit
PCS
Brands
Schneider
Unit
Individual
Best Seller
Yes
Products Ranking
Top 10 in Switches & Sockets
Frequently Asked Questions
What is the Schneider Electric 1P 20A C Curve MCB and where would I use it?
It's a single-pole miniature circuit breaker rated for 20A, designed to protect a single-phase circuit in residential or light commercial panels. It plugs onto a standard DIN rail and provides overcurrent protection with a C-curve trip characteristic.
What do the labels 1P, 20A, and C-curve mean on this MCB?
1P indicates one electrical pole (single-pole), 20A is the maximum continuous current it can safely carry, and C-curve describes the trip characteristics, which are suitable for moderate inrush loads such as lighting and small appliances.
What are the key electrical specifications of this MCB?
Key specs include a 500V rating, 6000A short-circuit current capability, and a breaking capacity around 10kA. It is UL 1077-listed with CE and CCC approvals, and features a thermoplastic housing for durability in typical panel environments.
How do I install this MCB in my panel?
Power should be off before installation. Mount the MCB on a standard 35mm DIN rail, connect the incoming line to the input terminal and the load to the output terminal, and firmly tighten the terminals. It is designed for easy plug-in installation in compatible panels.
What are common use cases for this MCB?
It's well-suited for protecting single-phase circuits in homes or small offices, such as lighting circuits, outlets, and small appliance circuits, where moderate inrush loads are expected.
What safety and compliance features does this MCB have?
It carries UL 1077 listing and has CE and CCC approvals. The thermoplastic housing offers UV and corrosion resistance, contributing to overall safety and longevity in typical electrical installations.
How does this MCB compare with other MCBs available on Fepy?
If you’re considering alternatives, you can compare with Siemens 1P 20A MCB (https://fepy.com/product/siemens-1p-20a-mcb), ABB 1P 20A MCB (https://fepy.com/product/abb-1p-20a-mcb), or Eaton 1P 20A MCB (https://fepy.com/product/eaton-1p-20a-mcb). Differences may include trip curve nuances (B, C, D), price, and panel compatibility; choose based on your load characteristics and panel ecosystem.
Is this MCB compatible with most Schneider Electric panels and DIN rail setups?
Yes, it is designed for Schneider Electric environments and DIN-rail mounting. Ensure you’re selecting a 1P 20A device with the same voltage rating (500V) and appropriate trip curve for your circuit.
What should I do if this MCB trips unexpectedly?
First, switch off the load and reset the breaker. Investigate the fault in the circuit (such as short circuits or overloaded conductors). If the fault is cleared, you can reset the breaker; if it trips repeatedly, consult a qualified electrician to diagnose the underlying issue.
How can I test the MCB after installation to ensure it’s functioning correctly?
After installation and powering the system, perform a normal-load test by turning on the circuit and confirming the load operates without nuisance trips. For a more thorough check, use a proper breaker tester or have a licensed electrician verify the instantaneous trip and overload protection.
Does this MCB handle inrush loads well, and when should I consider a different curve?
The C-curve is designed for moderate inrush loads like lighting and some electronics. If you expect heavy inrush loads (such as large motors or compressors), you might consider a different curve option (like D-curve) that offers higher instantaneous protection for such loads.
Frequently Asked Questions
It's a single-pole miniature circuit breaker rated for 20A, designed to protect a single-phase circuit in residential or light commercial panels. It plugs onto a standard DIN rail and provides overcurrent protection with a C-curve trip characteristic.
1P indicates one electrical pole (single-pole), 20A is the maximum continuous current it can safely carry, and C-curve describes the trip characteristics, which are suitable for moderate inrush loads such as lighting and small appliances.
Key specs include a 500V rating, 6000A short-circuit current capability, and a breaking capacity around 10kA. It is UL 1077-listed with CE and CCC approvals, and features a thermoplastic housing for durability in typical panel environments.
Power should be off before installation. Mount the MCB on a standard 35mm DIN rail, connect the incoming line to the input terminal and the load to the output terminal, and firmly tighten the terminals. It is designed for easy plug-in installation in compatible panels.
It's well-suited for protecting single-phase circuits in homes or small offices, such as lighting circuits, outlets, and small appliance circuits, where moderate inrush loads are expected.
It carries UL 1077 listing and has CE and CCC approvals. The thermoplastic housing offers UV and corrosion resistance, contributing to overall safety and longevity in typical electrical installations.
If you’re considering alternatives, you can compare with Siemens 1P 20A MCB (https://fepy.com/product/siemens-1p-20a-mcb), ABB 1P 20A MCB (https://fepy.com/product/abb-1p-20a-mcb), or Eaton 1P 20A MCB (https://fepy.com/product/eaton-1p-20a-mcb). Differences may include trip curve nuances (B, C, D), price, and panel compatibility; choose based on your load characteristics and panel ecosystem.
Yes, it is designed for Schneider Electric environments and DIN-rail mounting. Ensure you’re selecting a 1P 20A device with the same voltage rating (500V) and appropriate trip curve for your circuit.
First, switch off the load and reset the breaker. Investigate the fault in the circuit (such as short circuits or overloaded conductors). If the fault is cleared, you can reset the breaker; if it trips repeatedly, consult a qualified electrician to diagnose the underlying issue.
After installation and powering the system, perform a normal-load test by turning on the circuit and confirming the load operates without nuisance trips. For a more thorough check, use a proper breaker tester or have a licensed electrician verify the instantaneous trip and overload protection.
The C-curve is designed for moderate inrush loads like lighting and some electronics. If you expect heavy inrush loads (such as large motors or compressors), you might consider a different curve option (like D-curve) that offers higher instantaneous protection for such loads.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Similar Products
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 100 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy