    Key Features

    • 2 pole 100mA RCCB ELCB.
    • Circuit breaker for earth leakage detecting.
    • Novel Hager design with enhanced features.
    • Ideal for providing comprehensive safety.

+971 56 611 8671

Still need help? Contact on WhatsApp

Features & Benefits

Hager 2Pole 100Ma RCCB Earth Leakage Circuit Breaker (ELCB) is a precisely engineered electronic safety device that protects individual circuits from electrical shocks due to earth fault.

It consists of two poles: trip current pole and earth fault pole, which provides additional protection against direct and indirect contact, respectively.

The ELCB is equipped with a high sensitivity current transmitter along with a threshold detector that has pre-set trip current level of 100 milliamperes.

Moreover, the device has in-built fault detection protection for both indirect and direct contacts and dual purpose protection against voltage fluctuations, which is rare in the market comparison.

Key Specifications

Custom Stock Status

In Stock

Quantity Unit

PCS

Brands

Hager

Item Type

Circuit Breaker

Frequently Asked Questions

It is a two-pole residual current circuit breaker (RCCB), also known as an earth leakage circuit breaker (ELCB). It protects electrical circuits from shocks by detecting earth leakage and trips when leakage currents exceed 100 mA, providing enhanced safety in your installation.

Frequent tripping may indicate a real earth leakage or fault in a connected load. Start by unplugging loads and inspecting for moisture, damaged wiring, or faulty appliances. If trips persist, have a licensed electrician inspect the installation, wiring, and the device itself to identify leakage sources and confirm proper operation.

Value considerations include the 100 mA leakage-tripping capability, two-pole protection, and Hager’s design enhancements. If your circuits require effective earth leakage protection and dual-contact safeguarding, this model offers solid protection at a reasonable price point relative to similar high-quality RCCBs. Compare specifications, warranty, and after-sales support with other options on Fepy.com to determine the best value for your setup.

This RCCB is designed to integrate with standard two-pole RCCB-compatible setups common in many distribution boards. When mixing brands, verify terminal sizes, mounting compatibility, and electrical ratings to ensure proper fit and safe operation. Always consult the installation manual or a qualified electrician.

On Fepy.com you can find comparable RCCBs from other reputable brands. For example, you might look at: (1) Hager 2Pole 200mA RCCB ELCB — https://fepy.com/product/hager-2pole-200ma-rccb-elcb (2) Schneider Electric 2Pole 100mA RCCB ELCB — https://fepy.com/product/schneider-electric-2pole-100ma-rccb-elcb (3) Legrand 2Pole 100mA RCCB ELCB — https://fepy.com/product/legrand-2pole-100ma-rccb-elcb. These options provide similar protection levels with different trip thresholds or brand features; cross-check the exact specs to match your needs.

Always follow local electrical codes and standards. Installation should be performed by a licensed electrician. Ensure proper labeling, correct polarity, appropriate enclosure, and that the device is suitable for the system voltage and frequency. Regular checks and adherence to manufacturer guidelines help maintain safe operation.

It’s well-suited for protecting circuits with higher leakage risk, such as bathrooms, kitchens, outdoor outlets, and other wet areas, or any installation where robust earth leakage protection is desired. It’s also useful where dual protection against direct and indirect contact is beneficial.

If your specific model includes a built-in test button, use it according to the user manual. If there’s no test button described, consult the product manual or a qualified electrician for an appropriate testing procedure to verify leakage detection and tripping behavior.

General steps: (1) Power off the main supply. (2) Mount the device on the DIN rail inside the distribution board. (3) Connect the incoming line and neutral to the line terminals and connect the protected loads to the load terminals. (4) Tighten terminal screws to the recommended torque. (5) Replace the cover, restore power, and label the circuit. For exact torque values and terminal layouts, refer to the product manual.

Install it in the main distribution board (consumer unit) on the incoming supply side to protect the downstream circuits. It should be connected between the supply lines (live and neutral) and the protected loads so that any earth leakage on protected circuits trips the device.

Key specs include: 2 poles, a pre-set trip current of 100 milliamperes, earth leakage detection, built-in fault-detection for direct and indirect contact protection, and dual-purpose protection that also guards against voltage fluctuations. The description emphasizes Hager’s design enhancements for comprehensive safety.

The device monitors the balance between live and neutral conductors. If there is leakage to earth above 100 mA, it rapidly disconnects the circuit, reducing the risk of electric shock. The two-pole design helps ensure both conductors are disconnected in fault conditions for safer protection.

It is a two-pole residual current circuit breaker (RCCB), also known as an earth leakage circuit breaker (ELCB). It protects electrical circuits from shocks by detecting earth leakage and trips when leakage currents exceed 100 mA, providing enhanced safety in your installation.

Frequent tripping may indicate a real earth leakage or fault in a connected load. Start by unplugging loads and inspecting for moisture, damaged wiring, or faulty appliances. If trips persist, have a licensed electrician inspect the installation, wiring, and the device itself to identify leakage sources and confirm proper operation.

Value considerations include the 100 mA leakage-tripping capability, two-pole protection, and Hager’s design enhancements. If your circuits require effective earth leakage protection and dual-contact safeguarding, this model offers solid protection at a reasonable price point relative to similar high-quality RCCBs. Compare specifications, warranty, and after-sales support with other options on Fepy.com to determine the best value for your setup.

Ratings & Reviews

See what customers are saying

No reviews yet

Be the first to review this product after purchase.

No reviews yet. Reviews appear here once customers review their orders.

Manufacturer Warranty

Official warranty coverage from brand manufacturers

99% Claims resolved

Cash on Delivery

Choose Cash or Card as your payment

AED 100+ Min. order value

Secure Payment

100% secure payment processing

256-bit SSL encryption

Free Delivery

On all orders above AED 200 across UAE

Same Day In Abu Dhabi & Dubai

100% Genuine

Authentic products guaranteed

Authorized Distributor

Free Returns

7-day easy return policy

No questions Asked policy