FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
Delivery by Friday, 23 Oct
- 3A output suits compatible DC loads.
- Provides a regulated 12V DC output connection.
- Accepts a 110-220V AC mains input range.
- Designed for fixed low-voltage power systems.
- Model PSPS 3A supports clear product matching.
- Select load capacity within the rated current.
Key Features
Delivery by Friday, 23 Oct

- 100% free subscription
- Easy Registration
Features & Benefits
Product Type
AC-DC Power Supply identified under PowerSafe model PSPS 3A, allowing buyers to match the exact product reference before ordering.
DC Output
The unit provides 12V DC at a rated 3A; connected equipment must remain within this output capacity.
Installation
Electrical installation should be completed by a qualified person in accordance with the product rating and applicable UAE authority requirements.
Key Specifications
Custom Stock Status
In Stock
Quantity Unit
PCS
Model No
PSPS 3A
Brands
PowerSafe
Item Type
AC-DC Power Supply
Frequency
50/60hz
AC Voltage
110-220V AC
Country Of Origin
China
Usage
Supplying compatible 12V DC electrical loads
DC Voltage
12V DC
Output Current
3A
Frequently Asked Questions
What is the PowerSafe PSPS 3A power supply?
The PowerSafe PSPS 3A is an AC-to-DC power supply designed to provide a regulated 12V DC output at up to 3A for compatible fixed low-voltage equipment. It accepts a stated 110–220V AC input and is suitable for applications where mains electricity must be converted to 12V DC. Buyers should verify the model number, input range, output voltage, polarity and load requirement before installation.
What is the maximum output capacity of the PowerSafe 12V 3A power supply?
The rated output is 12V DC at a maximum of 3A, giving a nominal maximum capacity of 36W. The combined current drawn by all connected devices must not exceed 3A. For dependable operation, also consider startup current, cable voltage drop, ambient temperature and any continuous-load guidance stated by the equipment manufacturer.
Which devices can be powered by the PowerSafe PSPS 3A?
It can supply compatible equipment that requires regulated 12V DC and draws no more than 3A in total. Potential applications include selected access-control components, security devices, low-voltage control equipment and other fixed 12V DC loads. Compatibility must be confirmed from the connected device label or technical datasheet; matching voltage alone is not sufficient.
Is the PowerSafe PSPS 3A suitable for CCTV or access-control installations?
It may be suitable for CCTV, access-control or building-security equipment when every connected device is designed for 12V DC and the total current, including startup demand, remains within 3A. Check connector type, polarity, voltage-drop limits and any manufacturer-specific power requirements. Critical security systems may also require battery backup, monitored outputs or certified system power supplies not specified for this model.
How should the PowerSafe 110–220V AC to 12V DC power supply be installed?
Installation should be completed by a qualified electrician or competent low-voltage systems installer. Isolate the mains supply, confirm the incoming voltage, mount the unit in a suitable ventilated location, connect AC input and 12V DC output according to the product markings, and verify output polarity before energising the load. Suitable upstream isolation, overcurrent protection, earthing where required and strain relief should be provided in accordance with the installation design and local authority requirements.
Can the PowerSafe PSPS 3A be connected directly to a UAE mains supply?
The product has a stated input range of 110–220V AC, while UAE low-voltage supplies are commonly nominal 230V at 50Hz. Because 230V is above the listed 220V maximum, do not assume direct compatibility. The installer should verify the actual site voltage and obtain confirmation of the permitted input tolerance from the manufacturer or supplier before connection. A correctly rated alternative should be selected if the available supply falls outside the approved range.
How do I calculate whether my 12V DC load is compatible with this 3A power supply?
Add the current ratings of all devices that will operate simultaneously. The total must remain at or below 3A, and allowance should be made for startup or inrush current. If only wattage is shown, estimate current using current in amperes equals watts divided by 12 volts. For example, a 24W 12V load draws approximately 2A, subject to the device's actual specifications.
What cable considerations apply when installing this 12V DC power supply on a construction project?
Cable size should be selected according to load current, route length, installation method, ambient temperature and acceptable voltage drop. Voltage drop is especially important in 12V systems because long or undersized cables can prevent equipment from operating correctly. Keep AC and extra-low-voltage wiring appropriately segregated, protect cables from mechanical damage, label circuits clearly and use terminations suited to the conductor type.
Can multiple 12V devices be connected to the PowerSafe PSPS 3A?
Yes, multiple compatible 12V DC devices may be connected if the distribution arrangement is properly designed and their combined current does not exceed 3A. All devices must use the correct polarity and be suitable for the regulated 12V output. For construction and building-services installations, consider individually protected branches or a purpose-designed distribution module where several circuits are supplied.
Is the PowerSafe PSPS 3A suitable for outdoor use in the UAE?
Outdoor suitability is not established by the provided specifications. If installed outdoors or in dusty, humid or exposed construction areas, it should be housed in an enclosure with an IP rating appropriate to the location, while maintaining the ventilation and temperature conditions required by the manufacturer. It must also be protected from direct sunlight, rain, condensation, dust ingress and excessive heat.
What UAE installation requirements should be considered for this AC-DC power supply?
The installation should follow applicable UAE electrical regulations, project specifications and the requirements of the relevant local authority, such as DEWA, ADDC or the authority serving the project location. A qualified installer should confirm isolation, circuit protection, earthing, enclosure suitability, cable segregation and safe access for maintenance. Any consultant-approved material schedule or civil defence requirement associated with the wider system must also be checked.
Why are polarity and voltage checks important before connecting a 12V load?
Many 12V DC devices are polarity-sensitive. Reversing positive and negative connections, or applying the wrong voltage, can damage the connected equipment. Before connection, confirm the output terminal markings and device polarity, then test the output with a suitable meter. Carry out these checks with the load disconnected and follow safe isolation procedures on the AC input side.
What should be checked during commissioning of the PowerSafe PSPS 3A?
Confirm the AC input is within the approved range, verify secure terminations, check output polarity and measure the DC voltage before connecting equipment. After energising the load, confirm that total current remains within 3A and inspect for excessive heating, unstable voltage, unusual noise or intermittent operation. Record the circuit details and label the power supply and isolator for future maintenance.
How can voltage drop be reduced in a 12V DC construction installation?
Use an appropriately sized cable, shorten the DC cable route where practical and position the power supply closer to the load in a safe, accessible location. Ensure all terminals are clean and secure, because poor connections add resistance. The designer should calculate voltage drop using the actual cable length and load current, then verify the voltage at the equipment while it is operating.
What information should buyers verify before ordering the PowerSafe PSPS 3A in the UAE?
Verify that model PSPS 3A matches the required specification, the equipment needs 12V DC, and the maximum combined load does not exceed 3A or 36W nominal. Also confirm AC input compatibility with the site supply, output polarity, connection arrangement, installation environment, enclosure requirements and any project consultant or authority approvals. The listed country of origin is China.
Frequently Asked Questions
The PowerSafe PSPS 3A is an AC-to-DC power supply designed to provide a regulated 12V DC output at up to 3A for compatible fixed low-voltage equipment. It accepts a stated 110–220V AC input and is suitable for applications where mains electricity must be converted to 12V DC. Buyers should verify the model number, input range, output voltage, polarity and load requirement before installation.
The rated output is 12V DC at a maximum of 3A, giving a nominal maximum capacity of 36W. The combined current drawn by all connected devices must not exceed 3A. For dependable operation, also consider startup current, cable voltage drop, ambient temperature and any continuous-load guidance stated by the equipment manufacturer.
It can supply compatible equipment that requires regulated 12V DC and draws no more than 3A in total. Potential applications include selected access-control components, security devices, low-voltage control equipment and other fixed 12V DC loads. Compatibility must be confirmed from the connected device label or technical datasheet; matching voltage alone is not sufficient.
It may be suitable for CCTV, access-control or building-security equipment when every connected device is designed for 12V DC and the total current, including startup demand, remains within 3A. Check connector type, polarity, voltage-drop limits and any manufacturer-specific power requirements. Critical security systems may also require battery backup, monitored outputs or certified system power supplies not specified for this model.
Installation should be completed by a qualified electrician or competent low-voltage systems installer. Isolate the mains supply, confirm the incoming voltage, mount the unit in a suitable ventilated location, connect AC input and 12V DC output according to the product markings, and verify output polarity before energising the load. Suitable upstream isolation, overcurrent protection, earthing where required and strain relief should be provided in accordance with the installation design and local authority requirements.
The product has a stated input range of 110–220V AC, while UAE low-voltage supplies are commonly nominal 230V at 50Hz. Because 230V is above the listed 220V maximum, do not assume direct compatibility. The installer should verify the actual site voltage and obtain confirmation of the permitted input tolerance from the manufacturer or supplier before connection. A correctly rated alternative should be selected if the available supply falls outside the approved range.
Add the current ratings of all devices that will operate simultaneously. The total must remain at or below 3A, and allowance should be made for startup or inrush current. If only wattage is shown, estimate current using current in amperes equals watts divided by 12 volts. For example, a 24W 12V load draws approximately 2A, subject to the device's actual specifications.
Cable size should be selected according to load current, route length, installation method, ambient temperature and acceptable voltage drop. Voltage drop is especially important in 12V systems because long or undersized cables can prevent equipment from operating correctly. Keep AC and extra-low-voltage wiring appropriately segregated, protect cables from mechanical damage, label circuits clearly and use terminations suited to the conductor type.
Yes, multiple compatible 12V DC devices may be connected if the distribution arrangement is properly designed and their combined current does not exceed 3A. All devices must use the correct polarity and be suitable for the regulated 12V output. For construction and building-services installations, consider individually protected branches or a purpose-designed distribution module where several circuits are supplied.
Outdoor suitability is not established by the provided specifications. If installed outdoors or in dusty, humid or exposed construction areas, it should be housed in an enclosure with an IP rating appropriate to the location, while maintaining the ventilation and temperature conditions required by the manufacturer. It must also be protected from direct sunlight, rain, condensation, dust ingress and excessive heat.
The installation should follow applicable UAE electrical regulations, project specifications and the requirements of the relevant local authority, such as DEWA, ADDC or the authority serving the project location. A qualified installer should confirm isolation, circuit protection, earthing, enclosure suitability, cable segregation and safe access for maintenance. Any consultant-approved material schedule or civil defence requirement associated with the wider system must also be checked.
Many 12V DC devices are polarity-sensitive. Reversing positive and negative connections, or applying the wrong voltage, can damage the connected equipment. Before connection, confirm the output terminal markings and device polarity, then test the output with a suitable meter. Carry out these checks with the load disconnected and follow safe isolation procedures on the AC input side.
Confirm the AC input is within the approved range, verify secure terminations, check output polarity and measure the DC voltage before connecting equipment. After energising the load, confirm that total current remains within 3A and inspect for excessive heating, unstable voltage, unusual noise or intermittent operation. Record the circuit details and label the power supply and isolator for future maintenance.
Use an appropriately sized cable, shorten the DC cable route where practical and position the power supply closer to the load in a safe, accessible location. Ensure all terminals are clean and secure, because poor connections add resistance. The designer should calculate voltage drop using the actual cable length and load current, then verify the voltage at the equipment while it is operating.
Verify that model PSPS 3A matches the required specification, the equipment needs 12V DC, and the maximum combined load does not exceed 3A or 36W nominal. Also confirm AC input compatibility with the site supply, output polarity, connection arrangement, installation environment, enclosure requirements and any project consultant or authority approvals. The listed country of origin is China.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
