UNI-T TDR Cable Tester twisted pair cable coaxial cable & POE network cable with range 500 m and RJ11 RJ45 coax test ports UT 685B KIT
FREE Returns
Upgrade to Fepy Pro and get up to 10% off all orders.
- UT685B KIT TDR cable tester for professional testing.
- Traces cables for faster fault finding.
- RJ45 and RJ11 ports support cable checks.
- Useful for electricians and maintenance teams.
- Compact design suits tool bags and kits.
- Clear display supports quick field readings.
Key Features
Out of stock

- 100% free subscription
- Easy Registration
Features & Benefits
Application
Designed for network cabling, telecom, low-voltage installation, cable tracing, continuity checks, and fault finding, with UNI-T UT 685B KIT Wire Tracers configuration.
Functions
TDR cable tester kit.
Product Overview
Tests twisted-pair and coaxial cables.
Measurement Range
Cable length range up to 500m with 0.33m resolution.
Key Ratings
RJ11, RJ45, and coax test ports.
Measurement Functions
PoE detection for 802.3AF/AT/BT standards.
Key Specifications
Custom Stock Status
Out Of Stock
Quantity Unit
PCS
Best Seller
No
Model No
UT 685B KIT
Brands
UNI-T
Item Type
Wire Tracer
Country Of Origin
China
Frequently Asked Questions
What is the UNI-T TDR Cable Tester UT 685B KIT and what is it used for?
The UNI-T TDR Cable Tester UT 685B KIT is a time domain reflectometer kit for testing twisted-pair and coaxial cables. It is used for network cabling, telecom and low-voltage installation work, including continuity checks, cable tracing and fault finding. It also detects PoE on network cables, helping installers diagnose problems quickly.
What are the key specifications of the UNI-T TDR Cable Tester?
The tester covers cable lengths up to 500 m with a 0.33 m resolution. It has RJ11, RJ45 and coax test ports, so it handles telephone, network and coaxial cable. It also detects PoE for the 802.3af, 802.3at and 802.3bt standards. For battery type, accessories in the kit and accuracy details, check the label or manual.
What jobs is the UNI-T TDR Cable Tester best suited to?
It is best suited to locating faults in structured cabling, telephone lines and coaxial runs, such as breaks, shorts and damaged sections. Installers use it during new cable installation and when diagnosing failed links. Home users with a network cable run through walls or a coax feed to an aerial or TV point can also use it to find where a fault is.
How does the UNI-T TDR Cable Tester measure cable length and find faults?
A TDR sends a pulse along the cable and measures the reflection that returns from a break, short or the cable end. The time delay is converted into a distance, which is why the tester can give a length reading with 0.33 m resolution up to 500 m. Read the manual for cable type settings, as they affect distance accuracy.
How do I connect and start using the UNI-T TDR Cable Tester?
Disconnect the cable from any live equipment, then plug it into the matching port on the tester: RJ11 for telephone, RJ45 for network or the coax connector for coaxial cable. Switch on, select the correct cable type if required and start the test. Follow the manual for the order of steps and how to read the result.
How should I store and care for the UNI-T TDR Cable Tester kit?
After use, wipe the tester with a dry cloth and check the ports and leads for dirt or damage. Store the kit with its accessories in its case, away from direct sun, dust and moisture. In the UAE, avoid leaving it in a hot vehicle, because high temperatures can affect the screen and battery.
Is the UNI-T TDR Cable Tester suitable for UAE installation sites?
It suits network, telecom and low-voltage jobs in UAE offices, villas, towers and data rooms. Site conditions such as heat, dust and humidity can be hard on electronic instruments, so keep it in its case between tests and avoid leaving it in direct sunlight. Check the manual for the permitted operating temperature range.
How do installers and contractors use the UNI-T TDR Cable Tester on projects?
Low-voltage contractors use it to check installed cable lengths, locate breaks or shorts before handover and troubleshoot failed links without pulling cable out of ducts or ceilings. The PoE detection helps confirm whether a switch port is powering a device. It is a fault-finding tool, so use a dedicated certifier if a formal certification report is required.
Can home users use the UNI-T TDR Cable Tester for home network and TV cables?
Yes. Homeowners and DIYers can use it to check Ethernet cables run through walls, telephone lines, and coaxial cables feeding TV or satellite points. It can show roughly how far along a cable a fault is, saving time when working in ceilings or conduits. Read the manual first, as it is a technical instrument.
What safety precautions apply when using the UNI-T TDR Cable Tester?
Disconnect cables from active equipment before running a TDR test, and never connect the tester to mains power or any high-voltage circuit. PoE detection is intended for network cables only. Check the manual for the maximum input voltage, keep leads in good condition, and have electrical work carried out by a qualified person following UAE requirements.
Frequently Asked Questions
The UNI-T TDR Cable Tester UT 685B KIT is a time domain reflectometer kit for testing twisted-pair and coaxial cables. It is used for network cabling, telecom and low-voltage installation work, including continuity checks, cable tracing and fault finding. It also detects PoE on network cables, helping installers diagnose problems quickly.
The tester covers cable lengths up to 500 m with a 0.33 m resolution. It has RJ11, RJ45 and coax test ports, so it handles telephone, network and coaxial cable. It also detects PoE for the 802.3af, 802.3at and 802.3bt standards. For battery type, accessories in the kit and accuracy details, check the label or manual.
It is best suited to locating faults in structured cabling, telephone lines and coaxial runs, such as breaks, shorts and damaged sections. Installers use it during new cable installation and when diagnosing failed links. Home users with a network cable run through walls or a coax feed to an aerial or TV point can also use it to find where a fault is.
A TDR sends a pulse along the cable and measures the reflection that returns from a break, short or the cable end. The time delay is converted into a distance, which is why the tester can give a length reading with 0.33 m resolution up to 500 m. Read the manual for cable type settings, as they affect distance accuracy.
Disconnect the cable from any live equipment, then plug it into the matching port on the tester: RJ11 for telephone, RJ45 for network or the coax connector for coaxial cable. Switch on, select the correct cable type if required and start the test. Follow the manual for the order of steps and how to read the result.
After use, wipe the tester with a dry cloth and check the ports and leads for dirt or damage. Store the kit with its accessories in its case, away from direct sun, dust and moisture. In the UAE, avoid leaving it in a hot vehicle, because high temperatures can affect the screen and battery.
It suits network, telecom and low-voltage jobs in UAE offices, villas, towers and data rooms. Site conditions such as heat, dust and humidity can be hard on electronic instruments, so keep it in its case between tests and avoid leaving it in direct sunlight. Check the manual for the permitted operating temperature range.
Low-voltage contractors use it to check installed cable lengths, locate breaks or shorts before handover and troubleshoot failed links without pulling cable out of ducts or ceilings. The PoE detection helps confirm whether a switch port is powering a device. It is a fault-finding tool, so use a dedicated certifier if a formal certification report is required.
Yes. Homeowners and DIYers can use it to check Ethernet cables run through walls, telephone lines, and coaxial cables feeding TV or satellite points. It can show roughly how far along a cable a fault is, saving time when working in ceilings or conduits. Read the manual first, as it is a technical instrument.
Disconnect cables from active equipment before running a TDR test, and never connect the tester to mains power or any high-voltage circuit. PoE detection is intended for network cables only. Check the manual for the maximum input voltage, keep leads in good condition, and have electrical work carried out by a qualified person following UAE requirements.
Ratings & Reviews
See what customers are saying
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
No reviews yet
Be the first to review this product after purchase.
No reviews yet. Reviews appear here once customers review their orders.
More from UNI-T
Bestsellers from Electrical Testers & Tools
Why Buy From Fepy
We provide the best shopping experience
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
Years Experience
UAE Stores
Happy Customers
Products
Trusted by Leading Brands
We are authorized distributors for top global brands
Manufacturer Warranty
Official warranty coverage from brand manufacturers
99% Claims resolved
Cash on Delivery
Choose Cash or Card as your payment
AED 100+ Min. order value
Secure Payment
100% secure payment processing
256-bit SSL encryption
Free Delivery
On all orders above AED 200 across UAE
Same Day In Abu Dhabi & Dubai
100% Genuine
Authentic products guaranteed
Authorized Distributor
Free Returns
7-day easy return policy
No questions Asked policy
